{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/27277"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/27277","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Some two-component beta decay measurements","abstract":"The shorter half-life of a two-component beta decay was determined. Natural silver was activated with thermal neutrons to produce isotopes Ag108 and Ag110. The shorter half-life decay (that of Ag110) was isolated from that of Ag108 by measuring the decay of only the higher energy betas associated with Ag110. Because a large portion of the energy spectrum was excluded, pile-up corrections were necessary. The half-life was also determined using the more conventional two-component method. The single component method yielded a half-life of 23.26 =/- .03 seconds compared with 23.43 =/- .04 seconds determined by the two-component methods. (Only statistical uncertainties are shown above.) The techniques used for making pile-up corrections are described, and systematic errors are discussed. This investigation indicates that accurate half-life determinations can be obtained with the single-component method.","abstract_html":"The shorter half-life of a two-component beta decay was determined. Natural silver was activated with thermal neutrons to produce isotopes Ag108 and Ag110. The shorter half-life decay (that of Ag110) was isolated from that of Ag108 by measuring the decay of only the higher energy betas associated with Ag110. Because a large portion of the energy spectrum was excluded, pile-up corrections were necessary. The half-life was also determined using the more conventional two-component method. The single component method yielded a half-life of 23.26 =/- .03 seconds compared with 23.43 =/- .04 seconds determined by the two-component methods. (Only statistical uncertainties are shown above.) The techniques used for making pile-up corrections are described, and systematic errors are discussed. This investigation indicates that accurate half-life determinations can be obtained with the single-component method.","abstract_has_math":false,"creators":["Ballard, Clark Tilton, Jr.","Tichenor, James Robert, III"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Rodeback, G. W."],"committee_chairs":[],"committee_members":[],"year":1967,"date_issued":"1967-06","date_published":"1967-06","updated_at":"2026-11-24T23:53:27Z","subjects":["Physics"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/27277","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/27277","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F27277","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F27277","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rodeback, G. W."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Ballard, Clark Tilton, Jr.","Tichenor, James Robert, III"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1967"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-23T22:11:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-01-23T22:11:15Z"]},{"key":"dc:date.issued","label":"Date","values":["1967-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Silver","Half-life of silver 110","Beta decay","Two-component decay"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/27277"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The shorter half-life of a two-component beta decay was determined. Natural silver was activated with thermal neutrons to produce isotopes Ag108 and Ag110. The shorter half-life decay (that of Ag110) was isolated from that of Ag108 by measuring the decay of only the higher energy betas associated with Ag110. Because a large portion of the energy spectrum was excluded, pile-up corrections were necessary. The half-life was also determined using the more conventional two-component method. The single component method yielded a half-life of 23.26 =/- .03 seconds compared with 23.43 =/- .04 seconds determined by the two-component methods. (Only statistical uncertainties are shown above.) The techniques used for making pile-up corrections are described, and systematic errors are discussed. This investigation indicates that accurate half-life determinations can be obtained with the single-component method."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/sometwocomponent1094527277"]},{"key":"dc:title","label":"Title","values":["Some two-component beta decay measurements"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rodeback, G. W."],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Ballard, Clark Tilton, Jr.","Tichenor, James Robert, III"],"dc:date":["June 1967"],"dc:date.accessioned":["2013-01-23T22:11:15Z"],"dc:date.available":["2013-01-23T22:11:15Z"],"dc:date.issued":["1967-06"],"dc:description.abstract":["The shorter half-life of a two-component beta decay was determined. Natural silver was activated with thermal neutrons to produce isotopes Ag108 and Ag110. The shorter half-life decay (that of Ag110) was isolated from that of Ag108 by measuring the decay of only the higher energy betas associated with Ag110. Because a large portion of the energy spectrum was excluded, pile-up corrections were necessary. The half-life was also determined using the more conventional two-component method. The single component method yielded a half-life of 23.26 =/- .03 seconds compared with 23.43 =/- .04 seconds determined by the two-component methods. (Only statistical uncertainties are shown above.) The techniques used for making pile-up corrections are described, and systematic errors are discussed. This investigation indicates that accurate half-life determinations can be obtained with the single-component method."],"dc:description.uri":["http://archive.org/details/sometwocomponent1094527277"],"dc:identifier.uri":["https://hdl.handle.net/10945/27277"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Silver","Half-life of silver 110","Beta decay","Two-component decay"],"dc:subject.lcsh":["Physics"],"dc:title":["Some two-component beta decay measurements"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Army"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-24T23:53:27Z"}