{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/27845"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/27845","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Feasibility study to adapt the microflown vector sensor for underwater use","abstract":"This thesis investigates the feasibility of adapting the Microflown PU match vector sensor for underwater use. After testing the proper functioning of the sensor, the best materials for the capsule are determined based on acoustic properties. The capsule is designed and built by NPS staff. To predict the sensitivity of the encapsulated sensor, the characteristic equations are modified to reflect the new medium. In order to be able to predict the sensitivity of the encapsulated sensor, the performance ratio is determined between the sensitivity in air and the filling fluid of choice. Temperature dependency is introduced in the relevant parameters to be able to model the sensitivity at various operating temperatures. The measured sensitivity from the calibration report is then used to predict its performance in castor oil. The theoretical sensitivity model is verified by experimental data gathered from calibration studies at NUWC. The verified model is then used to analyze the consequences of changing critical operating parameters like the distance between the filaments and the operating temperature. Based on these calculations, recommendations are made for a better performing prototype. Eventually a new design is proposed that increases sensitivity significantly and is better adapted to operate in the filling fluid.","abstract_html":"This thesis investigates the feasibility of adapting the Microflown PU match vector sensor for underwater use. After testing the proper functioning of the sensor, the best materials for the capsule are determined based on acoustic properties. The capsule is designed and built by NPS staff. To predict the sensitivity of the encapsulated sensor, the characteristic equations are modified to reflect the new medium. In order to be able to predict the sensitivity of the encapsulated sensor, the performance ratio is determined between the sensitivity in air and the filling fluid of choice. Temperature dependency is introduced in the relevant parameters to be able to model the sensitivity at various operating temperatures. The measured sensitivity from the calibration report is then used to predict its performance in castor oil. The theoretical sensitivity model is verified by experimental data gathered from calibration studies at NUWC. The verified model is then used to analyze the consequences of changing critical operating parameters like the distance between the filaments and the operating temperature. Based on these calculations, recommendations are made for a better performing prototype. Eventually a new design is proposed that increases sensitivity significantly and is better adapted to operate in the filling fluid.","abstract_has_math":false,"creators":["Hezemans, Marnix J.M."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science In Engineering Acoustics","degree_level":"Masters","degree_discipline":"Engineering Acoustics","degree_department":null,"school":null,"contributors":[],"advisors":["Smith, Kevin B."],"committee_chairs":[],"committee_members":["Kapolka, Daphne"],"year":2012,"date_issued":"2012-12","date_published":"2012-12","updated_at":"2026-11-19T06:31:09Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/27845","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/27845","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F27845","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F27845","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Smith, Kevin B."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kapolka, Daphne"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Engineering Acoustics Academic Committee (EAAC)"]},{"key":"dc:creator","label":"Author","values":["Hezemans, Marnix J.M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:13:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:13:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["474bd71f-e4be-49fc-a024-b712415d9954"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Acoustics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science In Engineering Acoustics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Microflown","underwater sound detection","vector sensor","temperature dependency"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/27845"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates the feasibility of adapting the Microflown PU match vector sensor for underwater use. After testing the proper functioning of the sensor, the best materials for the capsule are determined based on acoustic properties. The capsule is designed and built by NPS staff. To predict the sensitivity of the encapsulated sensor, the characteristic equations are modified to reflect the new medium. In order to be able to predict the sensitivity of the encapsulated sensor, the performance ratio is determined between the sensitivity in air and the filling fluid of choice. Temperature dependency is introduced in the relevant parameters to be able to model the sensitivity at various operating temperatures. The measured sensitivity from the calibration report is then used to predict its performance in castor oil. The theoretical sensitivity model is verified by experimental data gathered from calibration studies at NUWC. The verified model is then used to analyze the consequences of changing critical operating parameters like the distance between the filaments and the operating temperature. Based on these calculations, recommendations are made for a better performing prototype. Eventually a new design is proposed that increases sensitivity significantly and is better adapted to operate in the filling fluid."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/feasibilitystudy1094527845"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["91 p."]},{"key":"dc:title","label":"Title","values":["Feasibility study to adapt the microflown vector sensor for underwater use"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, Royal Netherlands Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Smith, Kevin B."],"dc:contributor.committeemember":["Kapolka, Daphne"],"dc:contributor.other":["Engineering Acoustics Academic Committee (EAAC)"],"dc:creator":["Hezemans, Marnix J.M."],"dc:date.accessioned":["2013-02-15T23:13:41Z"],"dc:date.available":["2013-02-15T23:13:41Z"],"dc:date.issued":["2012-12"],"dc:description.abstract":["This thesis investigates the feasibility of adapting the Microflown PU match vector sensor for underwater use. After testing the proper functioning of the sensor, the best materials for the capsule are determined based on acoustic properties. The capsule is designed and built by NPS staff. To predict the sensitivity of the encapsulated sensor, the characteristic equations are modified to reflect the new medium. In order to be able to predict the sensitivity of the encapsulated sensor, the performance ratio is determined between the sensitivity in air and the filling fluid of choice. Temperature dependency is introduced in the relevant parameters to be able to model the sensitivity at various operating temperatures. The measured sensitivity from the calibration report is then used to predict its performance in castor oil. The theoretical sensitivity model is verified by experimental data gathered from calibration studies at NUWC. The verified model is then used to analyze the consequences of changing critical operating parameters like the distance between the filaments and the operating temperature. Based on these calculations, recommendations are made for a better performing prototype. Eventually a new design is proposed that increases sensitivity significantly and is better adapted to operate in the filling fluid."],"dc:description.award":["Outstanding Thesis"],"dc:description.uri":["http://archive.org/details/feasibilitystudy1094527845"],"dc:format.extent":["91 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/27845"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.orgunit":["474bd71f-e4be-49fc-a024-b712415d9954"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["Copyright is reserved by the copyright owner.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["Microflown","underwater sound detection","vector sensor","temperature dependency"],"dc:title":["Feasibility study to adapt the microflown vector sensor for underwater use"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, Royal Netherlands Navy"],"thesis:degree_discipline":["Engineering Acoustics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science In Engineering Acoustics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:31:09Z"}