{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/27875"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/27875","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Modeling and assessment of alternative cooling methods of the Combat Operation Center","abstract":"The Marine Corps Combat Operations Center provides formidable situational awareness and command and control capability using a robust mobile data center. This capability incurs a cost in fuel and restricted mobility due to the size and weight of the cooling and electrical generation. Enhancing the energy efficiency through alternative cooling methods will enhance the Marine Corps tactical flexibility on the battlefield. In both Iraq and Afghanistan, the Improvised Explosive Device threat is of grave concern. Reducing the frequency of fuel convoys may reduce the associated casualties that result. In this research, a model was created to predict potential reduction in fuel consumption by using alternative methods of cooling. The model considers all the sources of heat load introduced into the Combat Operations Center environment and estimates the amount of electricity required to maintain a set point temperature. An alternative method of cooling is introduced to determine whether it has the potential to reduce fuel consumption. A substantive increase in efficiency indicates further research has merit. The model offers an analytical method for exploring alternative cooling methods that may be used either individually or in concert to reduce the fuel required by the Combat Operations Center.","abstract_html":"The Marine Corps Combat Operations Center provides formidable situational awareness and command and control capability using a robust mobile data center. This capability incurs a cost in fuel and restricted mobility due to the size and weight of the cooling and electrical generation. Enhancing the energy efficiency through alternative cooling methods will enhance the Marine Corps tactical flexibility on the battlefield. In both Iraq and Afghanistan, the Improvised Explosive Device threat is of grave concern. Reducing the frequency of fuel convoys may reduce the associated casualties that result. In this research, a model was created to predict potential reduction in fuel consumption by using alternative methods of cooling. The model considers all the sources of heat load introduced into the Combat Operations Center environment and estimates the amount of electricity required to maintain a set point temperature. An alternative method of cooling is introduced to determine whether it has the potential to reduce fuel consumption. A substantive increase in efficiency indicates further research has merit. The model offers an analytical method for exploring alternative cooling methods that may be used either individually or in concert to reduce the fuel required by the Combat Operations Center.","abstract_has_math":false,"creators":["Moreno, Matthew S."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science In Information Technology","degree_level":"Masters","degree_discipline":"Information Technology","degree_department":"Information Sciences (IS)","school":null,"contributors":[],"advisors":["Shing, Man-Tak"],"committee_chairs":[],"committee_members":["Barreto, Albert"],"year":2012,"date_issued":"2012-12","date_published":"2012-12","updated_at":"2026-11-19T06:31:09Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/27875","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/27875","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F27875","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F27875","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Shing, Man-Tak"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Barreto, Albert"]},{"key":"dc:contributor.department","label":"Department","values":["Information Sciences (IS)"]},{"key":"dc:creator","label":"Author","values":["Moreno, Matthew S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:13:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:13:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["74f4d405-0bff-4b6e-9446-edae3a8b11bb"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Information Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science In Information Technology"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Modeling","Efficiency","COC Tactical Data Processing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/27875"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Marine Corps Combat Operations Center provides formidable situational awareness and command and control capability using a robust mobile data center. This capability incurs a cost in fuel and restricted mobility due to the size and weight of the cooling and electrical generation. Enhancing the energy efficiency through alternative cooling methods will enhance the Marine Corps tactical flexibility on the battlefield. In both Iraq and Afghanistan, the Improvised Explosive Device threat is of grave concern. Reducing the frequency of fuel convoys may reduce the associated casualties that result. In this research, a model was created to predict potential reduction in fuel consumption by using alternative methods of cooling. The model considers all the sources of heat load introduced into the Combat Operations Center environment and estimates the amount of electricity required to maintain a set point temperature. An alternative method of cooling is introduced to determine whether it has the potential to reduce fuel consumption. A substantive increase in efficiency indicates further research has merit. The model offers an analytical method for exploring alternative cooling methods that may be used either individually or in concert to reduce the fuel required by the Combat Operations Center."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/modelingndssessm1094527875"]},{"key":"dc:title","label":"Title","values":["Modeling and assessment of alternative cooling methods of the Combat Operation Center"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Marine Corps"]}]}],"canonical_facts":{"dc:contributor.advisor":["Shing, Man-Tak"],"dc:contributor.committeemember":["Barreto, Albert"],"dc:contributor.department":["Information Sciences (IS)"],"dc:creator":["Moreno, Matthew S."],"dc:date.accessioned":["2013-02-15T23:13:50Z"],"dc:date.available":["2013-02-15T23:13:50Z"],"dc:date.issued":["2012-12"],"dc:description.abstract":["The Marine Corps Combat Operations Center provides formidable situational awareness and command and control capability using a robust mobile data center. This capability incurs a cost in fuel and restricted mobility due to the size and weight of the cooling and electrical generation. Enhancing the energy efficiency through alternative cooling methods will enhance the Marine Corps tactical flexibility on the battlefield. In both Iraq and Afghanistan, the Improvised Explosive Device threat is of grave concern. Reducing the frequency of fuel convoys may reduce the associated casualties that result. In this research, a model was created to predict potential reduction in fuel consumption by using alternative methods of cooling. The model considers all the sources of heat load introduced into the Combat Operations Center environment and estimates the amount of electricity required to maintain a set point temperature. An alternative method of cooling is introduced to determine whether it has the potential to reduce fuel consumption. A substantive increase in efficiency indicates further research has merit. The model offers an analytical method for exploring alternative cooling methods that may be used either individually or in concert to reduce the fuel required by the Combat Operations Center."],"dc:description.uri":["http://archive.org/details/modelingndssessm1094527875"],"dc:identifier.uri":["https://hdl.handle.net/10945/27875"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["74f4d405-0bff-4b6e-9446-edae3a8b11bb"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Modeling","Efficiency","COC Tactical Data Processing"],"dc:title":["Modeling and assessment of alternative cooling methods of the Combat Operation Center"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Marine Corps"],"thesis:degree_discipline":["Information Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science In Information Technology"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:31:09Z"}