{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/27924"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/27924","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Design of a maximum power point tracker with simulation, analysis, and comparison of algorithms","abstract":"In this thesis, the advantages of three different maximum power point tracking (MPPT) algorithm are investigated. By simulation, the performance and efficiency of these algorithms was analyzed. By using MATLAB's SimPowerSystems block set, we created the model comprised of a Kyocera KD135GX-LP solar panel powering a buck converter controlled by the MPPT algorithms driving a resistive load. The main objective was to track the maximum power point (MPP) of the solar array by modulating the buck converter's duty cycle, thereby, optimizing the power output of the panel. The three algorithms observed performance was on par with other real world tests of these algorithms as seen in other published work. The Perturb and Observe (P&O) algorithm performed with a higher overall efficiency and was able to track the MPP quickly, while the Incremental Conductance (InC) algorithm had similar performance but requires more intensive calculations. The analysis of these algorithms led to a greater understanding of where the inefficiencies of this type of system are located, allowing improvement in future work on this subject.","abstract_html":"In this thesis, the advantages of three different maximum power point tracking (MPPT) algorithm are investigated. By simulation, the performance and efficiency of these algorithms was analyzed. By using MATLAB&#x27;s SimPowerSystems block set, we created the model comprised of a Kyocera KD135GX-LP solar panel powering a buck converter controlled by the MPPT algorithms driving a resistive load. The main objective was to track the maximum power point (MPP) of the solar array by modulating the buck converter&#x27;s duty cycle, thereby, optimizing the power output of the panel. The three algorithms observed performance was on par with other real world tests of these algorithms as seen in other published work. The Perturb and Observe (P&amp;O) algorithm performed with a higher overall efficiency and was able to track the MPP quickly, while the Incremental Conductance (InC) algorithm had similar performance but requires more intensive calculations. The analysis of these algorithms led to a greater understanding of where the inefficiencies of this type of system are located, allowing improvement in future work on this subject.","abstract_has_math":false,"creators":["Wurz, Jeff"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"Master of Science In Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Ashton, Robert"],"committee_chairs":[],"committee_members":["Dobrokhodov, Vladimir"],"year":2012,"date_issued":"2012-12","date_published":"2012-12","updated_at":"2026-11-19T06:31:09Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/27924","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/27924","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F27924","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F27924","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ashton, Robert"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Dobrokhodov, Vladimir"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Wurz, Jeff"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Dec-12"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:14:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:14:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science In Electrical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["MPPT, Maximum power point tracker, buck converter, solar array, simulation, MATLAB, incremental conductance, perturb and observe."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/27924"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, the advantages of three different maximum power point tracking (MPPT) algorithm are investigated. By simulation, the performance and efficiency of these algorithms was analyzed. By using MATLAB's SimPowerSystems block set, we created the model comprised of a Kyocera KD135GX-LP solar panel powering a buck converter controlled by the MPPT algorithms driving a resistive load. The main objective was to track the maximum power point (MPP) of the solar array by modulating the buck converter's duty cycle, thereby, optimizing the power output of the panel. The three algorithms observed performance was on par with other real world tests of these algorithms as seen in other published work. The Perturb and Observe (P&O) algorithm performed with a higher overall efficiency and was able to track the MPP quickly, while the Incremental Conductance (InC) algorithm had similar performance but requires more intensive calculations. The analysis of these algorithms led to a greater understanding of where the inefficiencies of this type of system are located, allowing improvement in future work on this subject."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/designofmaximump1094527924"]},{"key":"dc:title","label":"Title","values":["Design of a maximum power point tracker with simulation, analysis, and comparison of algorithms"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Civilian, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ashton, Robert"],"dc:contributor.committeemember":["Dobrokhodov, Vladimir"],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Wurz, Jeff"],"dc:date":["Dec-12"],"dc:date.accessioned":["2013-02-15T23:14:07Z"],"dc:date.available":["2013-02-15T23:14:07Z"],"dc:date.issued":["2012-12"],"dc:description.abstract":["In this thesis, the advantages of three different maximum power point tracking (MPPT) algorithm are investigated. By simulation, the performance and efficiency of these algorithms was analyzed. By using MATLAB's SimPowerSystems block set, we created the model comprised of a Kyocera KD135GX-LP solar panel powering a buck converter controlled by the MPPT algorithms driving a resistive load. The main objective was to track the maximum power point (MPP) of the solar array by modulating the buck converter's duty cycle, thereby, optimizing the power output of the panel. The three algorithms observed performance was on par with other real world tests of these algorithms as seen in other published work. The Perturb and Observe (P&O) algorithm performed with a higher overall efficiency and was able to track the MPP quickly, while the Incremental Conductance (InC) algorithm had similar performance but requires more intensive calculations. The analysis of these algorithms led to a greater understanding of where the inefficiencies of this type of system are located, allowing improvement in future work on this subject."],"dc:description.uri":["http://archive.org/details/designofmaximump1094527924"],"dc:identifier.uri":["https://hdl.handle.net/10945/27924"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["MPPT, Maximum power point tracker, buck converter, solar array, simulation, MATLAB, incremental conductance, perturb and observe."],"dc:title":["Design of a maximum power point tracker with simulation, analysis, and comparison of algorithms"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Civilian, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science In Electrical Engineering"]},"updated_at":"2026-11-19T06:31:09Z"}