{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28043"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28043","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Comparison of alkali ion emitters.","abstract":"Lithium, Potassium, and Cesium ion sources have been studied using devices based on thermal emission from a Beta- Eucryptite structure as possible ion sources for use in satellite charge control. The experiments evaluated the power requirements of the different ion emitters to produce approximately 10(mA) of current and tested the effects of using an Osmium-Ruthenium coating to increase the work function of the emitter surface. Lifetime tests of the different ion emitters were also performed. Analysis of the experimental findings showed that Lithium ion sources with a lifetime of 93 hours and Potassium ion sources with a lifetime of 44 hours produced acceptable current levels for use in spacecraft charge control devices. Potassium sources produced the necessary current, 10(mA), at 140°(C) lower temperature than the Lithium sources. All of the coated sources produced wildly fluctuating currents at the 10(jiA) level and were not acceptable for the purpose intended.","abstract_html":"Lithium, Potassium, and Cesium ion sources have been studied using devices based on thermal emission from a Beta- Eucryptite structure as possible ion sources for use in satellite charge control. The experiments evaluated the power requirements of the different ion emitters to produce approximately 10(mA) of current and tested the effects of using an Osmium-Ruthenium coating to increase the work function of the emitter surface. Lifetime tests of the different ion emitters were also performed. Analysis of the experimental findings showed that Lithium ion sources with a lifetime of 93 hours and Potassium ion sources with a lifetime of 44 hours produced acceptable current levels for use in spacecraft charge control devices. Potassium sources produced the necessary current, 10(mA), at 140°(C) lower temperature than the Lithium sources. All of the coated sources produced wildly fluctuating currents at the 10(jiA) level and were not acceptable for the purpose intended.","abstract_has_math":false,"creators":["Gant, Dean Alan"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":"Naval Postgraduate School","contributors":[],"advisors":["Olsen,Chris"],"committee_chairs":[],"committee_members":["Heinz, O."],"year":1991,"date_issued":"1991-12","date_published":"1991-12","updated_at":"2026-11-21T22:33:11Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28043","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28043","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28043","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Olsen,Chris"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Heinz, O."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Gant, Dean Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:30:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:30:32Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["alkali ion emitters"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28043"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lithium, Potassium, and Cesium ion sources have been studied using devices based on thermal emission from a Beta- Eucryptite structure as possible ion sources for use in satellite charge control. The experiments evaluated the power requirements of the different ion emitters to produce approximately 10(mA) of current and tested the effects of using an Osmium-Ruthenium coating to increase the work function of the emitter surface. Lifetime tests of the different ion emitters were also performed. Analysis of the experimental findings showed that Lithium ion sources with a lifetime of 93 hours and Potassium ion sources with a lifetime of 44 hours produced acceptable current levels for use in spacecraft charge control devices. Potassium sources produced the necessary current, 10(mA), at 140°(C) lower temperature than the Lithium sources. All of the coated sources produced wildly fluctuating currents at the 10(jiA) level and were not acceptable for the purpose intended."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/comparisonoflkal1094528043"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["86 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Comparison of alkali ion emitters."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Olsen,Chris"],"dc:contributor.committeemember":["Heinz, O."],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Gant, Dean Alan"],"dc:date.accessioned":["2013-02-15T23:30:32Z"],"dc:date.available":["2013-02-15T23:30:32Z"],"dc:date.issued":["1991-12"],"dc:description.abstract":["Lithium, Potassium, and Cesium ion sources have been studied using devices based on thermal emission from a Beta- Eucryptite structure as possible ion sources for use in satellite charge control. The experiments evaluated the power requirements of the different ion emitters to produce approximately 10(mA) of current and tested the effects of using an Osmium-Ruthenium coating to increase the work function of the emitter surface. Lifetime tests of the different ion emitters were also performed. Analysis of the experimental findings showed that Lithium ion sources with a lifetime of 93 hours and Potassium ion sources with a lifetime of 44 hours produced acceptable current levels for use in spacecraft charge control devices. Potassium sources produced the necessary current, 10(mA), at 140°(C) lower temperature than the Lithium sources. All of the coated sources produced wildly fluctuating currents at the 10(jiA) level and were not acceptable for the purpose intended."],"dc:description.uri":["http://archive.org/details/comparisonoflkal1094528043"],"dc:format.extent":["86 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/28043"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["alkali ion emitters"],"dc:title":["Comparison of alkali ion emitters."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Army"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:33:11Z"}