{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28202"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28202","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"An Experimental Investigation of the Vortex-Sink Angular Rate Sensor.","abstract":"The purpose of this investigation was to experimentally determine the performance characteristics of certain probe geometries and their respective locations in the sink tube of a pneumatic angular rate sensor. Sensor response was determined for various flow rates and angular velocities for each test condition. It was found that the pickoff element placed inside the sink tube yields a longer linear-response range than the one placed outside the sink tube. Use of one of the special flow dividing plates, with the probe located outside the sink tube, improves the linear response range of the sensor for all flow rates, but increases the magnitude of the response only for the lower flow rates. It was also observed that neither the shortening of the sink tube length downstream of the pickoff location nor the presence of a shallow circumferential groove at the midsection of the pickoff element alters the performance of the probe.","abstract_html":"The purpose of this investigation was to experimentally determine the performance characteristics of certain probe geometries and their respective locations in the sink tube of a pneumatic angular rate sensor. Sensor response was determined for various flow rates and angular velocities for each test condition. It was found that the pickoff element placed inside the sink tube yields a longer linear-response range than the one placed outside the sink tube. Use of one of the special flow dividing plates, with the probe located outside the sink tube, improves the linear response range of the sensor for all flow rates, but increases the magnitude of the response only for the lower flow rates. It was also observed that neither the shortening of the sink tube length downstream of the pickoff location nor the presence of a shallow circumferential groove at the midsection of the pickoff element alters the performance of the probe.","abstract_has_math":false,"creators":["Cunanan, Carlito Y."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Sarpkaya, T."],"committee_chairs":[],"committee_members":[],"year":1968,"date_issued":"1968-09","date_published":"1968-09","updated_at":"2026-11-20T22:16:03Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28202","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28202","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F28202","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28202","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sarpkaya, T."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Cunanan, Carlito Y."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:31:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:31:44Z"]},{"key":"dc:date.issued","label":"Date","values":["1968-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28202"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this investigation was to experimentally determine the performance characteristics of certain probe geometries and their respective locations in the sink tube of a pneumatic angular rate sensor. Sensor response was determined for various flow rates and angular velocities for each test condition. It was found that the pickoff element placed inside the sink tube yields a longer linear-response range than the one placed outside the sink tube. Use of one of the special flow dividing plates, with the probe located outside the sink tube, improves the linear response range of the sensor for all flow rates, but increases the magnitude of the response only for the lower flow rates. It was also observed that neither the shortening of the sink tube length downstream of the pickoff location nor the presence of a shallow circumferential groove at the midsection of the pickoff element alters the performance of the probe."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/anexperimentalin1094528202"]},{"key":"dc:title","label":"Title","values":["An Experimental Investigation of the Vortex-Sink Angular Rate Sensor."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, Philippine Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sarpkaya, T."],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Cunanan, Carlito Y."],"dc:date.accessioned":["2013-02-15T23:31:44Z"],"dc:date.available":["2013-02-15T23:31:44Z"],"dc:date.issued":["1968-09"],"dc:description.abstract":["The purpose of this investigation was to experimentally determine the performance characteristics of certain probe geometries and their respective locations in the sink tube of a pneumatic angular rate sensor. Sensor response was determined for various flow rates and angular velocities for each test condition. It was found that the pickoff element placed inside the sink tube yields a longer linear-response range than the one placed outside the sink tube. Use of one of the special flow dividing plates, with the probe located outside the sink tube, improves the linear response range of the sensor for all flow rates, but increases the magnitude of the response only for the lower flow rates. It was also observed that neither the shortening of the sink tube length downstream of the pickoff location nor the presence of a shallow circumferential groove at the midsection of the pickoff element alters the performance of the probe."],"dc:description.uri":["http://archive.org/details/anexperimentalin1094528202"],"dc:identifier.uri":["https://hdl.handle.net/10945/28202"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:title":["An Experimental Investigation of the Vortex-Sink Angular Rate Sensor."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, Philippine Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-20T22:16:03Z"}