{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28236"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28236","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Frequency control of a CO(2) laser using stark cell stabilization","abstract":"Preliminary studies have been carried out for the frequency and intensity stabilization of the output of a Sylvania Model 941 Carbon Dioxide laser, by feedback control of resonator length. Fluctuations due to discharge current and temperature and flow rate of coolant were studied. Current regulation of the power supply was found to be necessary for intensity stability. Cavity length tuning allowed vibration-rotation line selection, with a strong hysteresis effect. A computer analysis of error signal production for a pyroelectric detector and for a HgCdTe detector indicated that phase sensitive detection of the first harmonic signal component gave the typical frequency discriminant. Operation of a servo loop integrator for the feedback loop has been considered. A suitable Stark Effect absorption cell for feedback signal generation has been constructed, but has not been applied to the laser.","abstract_html":"Preliminary studies have been carried out for the frequency and intensity stabilization of the output of a Sylvania Model 941 Carbon Dioxide laser, by feedback control of resonator length. Fluctuations due to discharge current and temperature and flow rate of coolant were studied. Current regulation of the power supply was found to be necessary for intensity stability. Cavity length tuning allowed vibration-rotation line selection, with a strong hysteresis effect. A computer analysis of error signal production for a pyroelectric detector and for a HgCdTe detector indicated that phase sensitive detection of the first harmonic signal component gave the typical frequency discriminant. Operation of a servo loop integrator for the feedback loop has been considered. A suitable Stark Effect absorption cell for feedback signal generation has been constructed, but has not been applied to the laser.","abstract_has_math":false,"creators":["Brown, Daniel Morris"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":"Naval Postgraduate School","contributors":[],"advisors":["Cooper, A.W."],"committee_chairs":[],"committee_members":["Crittenden, E.C."],"year":1979,"date_issued":"1979-06","date_published":"1979-06","updated_at":"2026-11-26T00:10:31Z","subjects":["Physics"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28236","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28236","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F28236","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28236","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cooper, A.W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Crittenden, E.C."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Brown, Daniel Morris"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:31:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:31:56Z"]},{"key":"dc:date.issued","label":"Date","values":["1979-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Laser","Stabilization","Stark"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28236"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Preliminary studies have been carried out for the frequency and intensity stabilization of the output of a Sylvania Model 941 Carbon Dioxide laser, by feedback control of resonator length. Fluctuations due to discharge current and temperature and flow rate of coolant were studied. Current regulation of the power supply was found to be necessary for intensity stability. Cavity length tuning allowed vibration-rotation line selection, with a strong hysteresis effect. A computer analysis of error signal production for a pyroelectric detector and for a HgCdTe detector indicated that phase sensitive detection of the first harmonic signal component gave the typical frequency discriminant. Operation of a servo loop integrator for the feedback loop has been considered. A suitable Stark Effect absorption cell for feedback signal generation has been constructed, but has not been applied to the laser."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/frequencycontrol1094528236"]},{"key":"dc:title","label":"Title","values":["Frequency control of a CO(2) laser using stark cell stabilization"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Coast Guard"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cooper, A.W."],"dc:contributor.committeemember":["Crittenden, E.C."],"dc:contributor.department":["Physics"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Brown, Daniel Morris"],"dc:date.accessioned":["2013-02-15T23:31:56Z"],"dc:date.available":["2013-02-15T23:31:56Z"],"dc:date.issued":["1979-06"],"dc:description.abstract":["Preliminary studies have been carried out for the frequency and intensity stabilization of the output of a Sylvania Model 941 Carbon Dioxide laser, by feedback control of resonator length. Fluctuations due to discharge current and temperature and flow rate of coolant were studied. Current regulation of the power supply was found to be necessary for intensity stability. Cavity length tuning allowed vibration-rotation line selection, with a strong hysteresis effect. A computer analysis of error signal production for a pyroelectric detector and for a HgCdTe detector indicated that phase sensitive detection of the first harmonic signal component gave the typical frequency discriminant. Operation of a servo loop integrator for the feedback loop has been considered. A suitable Stark Effect absorption cell for feedback signal generation has been constructed, but has not been applied to the laser."],"dc:description.uri":["http://archive.org/details/frequencycontrol1094528236"],"dc:identifier.uri":["https://hdl.handle.net/10945/28236"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Laser","Stabilization","Stark"],"dc:subject.lcsh":["Physics"],"dc:title":["Frequency control of a CO(2) laser using stark cell stabilization"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Coast Guard"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:10:31Z"}