{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28258"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28258","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Heat transfer, adiabatic effectiveness and injectant distributions downstream of single rows and two staggered rows of film-cooling holes with simple and compound angles","abstract":"Experimental results for two compound angle injection systems (configuration 1 and 3), and for a single injection system (configuration 2) are compared in this thesis. The effects of blowing ratio, spanwise hole spacing, hole angle orientation, and streamwise position (x/d) are discussed in reference to measurements of spanwise-averaged adiabatic effectiveness, iso-energetic Stanton number and Stanton number for 0 approximately equal to 1.5 obtained downstream of both one row of holes and two staggered rows of holes. Results indicate that effectiveness depends mostly on four parameters: simple or compound angle injection, spanwise hole spacing, one or two rows of holes, and blowing ratio. Results show that for a specified blowing ratio, for all configurations tested to date, spanwise-averaged adiabatic effectiveness is greatest at lower x/d values but decreases with streamwise development as the injectant is convected downstream. The rate of spanwise-averaged adiabatic effectiveness decrease is dependent on the blowing ratio, and mostly a result of lift-off of the injectant from the test surface at x/d values less than about 20. At larger x/d, spanwise-averaged adiabatic effectiveness values generally increase with blowing ratio mostly because of grater amounts of injectant along the test surface,. Results also show that the iso-energetic Stanton number ratio lies between 1 and 1.35 for all cases studied and generally increases with blowing ratio for a given x/d.","abstract_html":"Experimental results for two compound angle injection systems (configuration 1 and 3), and for a single injection system (configuration 2) are compared in this thesis. The effects of blowing ratio, spanwise hole spacing, hole angle orientation, and streamwise position (x/d) are discussed in reference to measurements of spanwise-averaged adiabatic effectiveness, iso-energetic Stanton number and Stanton number for 0 approximately equal to 1.5 obtained downstream of both one row of holes and two staggered rows of holes. Results indicate that effectiveness depends mostly on four parameters: simple or compound angle injection, spanwise hole spacing, one or two rows of holes, and blowing ratio. Results show that for a specified blowing ratio, for all configurations tested to date, spanwise-averaged adiabatic effectiveness is greatest at lower x/d values but decreases with streamwise development as the injectant is convected downstream. The rate of spanwise-averaged adiabatic effectiveness decrease is dependent on the blowing ratio, and mostly a result of lift-off of the injectant from the test surface at x/d values less than about 20. At larger x/d, spanwise-averaged adiabatic effectiveness values generally increase with blowing ratio mostly because of grater amounts of injectant along the test surface,. Results also show that the iso-energetic Stanton number ratio lies between 1 and 1.35 for all cases studied and generally increases with blowing ratio for a given x/d.","abstract_has_math":false,"creators":["Jackson, Stephen Mark"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Ligrani, Phillip"],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991-12","date_published":"1991-12","updated_at":"2026-11-21T22:32:58Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28258","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28258","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F28258","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28258","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ligrani, Phillip"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Jackson, Stephen Mark"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1991"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:32:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:32:05Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Compound angle injection","Simple angle injection","Film cooling","Turbulent boundary layer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28258"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Experimental results for two compound angle injection systems (configuration 1 and 3), and for a single injection system (configuration 2) are compared in this thesis. The effects of blowing ratio, spanwise hole spacing, hole angle orientation, and streamwise position (x/d) are discussed in reference to measurements of spanwise-averaged adiabatic effectiveness, iso-energetic Stanton number and Stanton number for 0 approximately equal to 1.5 obtained downstream of both one row of holes and two staggered rows of holes. Results indicate that effectiveness depends mostly on four parameters: simple or compound angle injection, spanwise hole spacing, one or two rows of holes, and blowing ratio. Results show that for a specified blowing ratio, for all configurations tested to date, spanwise-averaged adiabatic effectiveness is greatest at lower x/d values but decreases with streamwise development as the injectant is convected downstream. The rate of spanwise-averaged adiabatic effectiveness decrease is dependent on the blowing ratio, and mostly a result of lift-off of the injectant from the test surface at x/d values less than about 20. At larger x/d, spanwise-averaged adiabatic effectiveness values generally increase with blowing ratio mostly because of grater amounts of injectant along the test surface,. Results also show that the iso-energetic Stanton number ratio lies between 1 and 1.35 for all cases studied and generally increases with blowing ratio for a given x/d."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/heattransferdiab1094528258"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["224 p."]},{"key":"dc:title","label":"Title","values":["Heat transfer, adiabatic effectiveness and injectant distributions downstream of single rows and two staggered rows of film-cooling holes with simple and compound angles"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ligrani, Phillip"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:creator":["Jackson, Stephen Mark"],"dc:date":["December 1991"],"dc:date.accessioned":["2013-02-15T23:32:05Z"],"dc:date.available":["2013-02-15T23:32:05Z"],"dc:date.issued":["1991-12"],"dc:description.abstract":["Experimental results for two compound angle injection systems (configuration 1 and 3), and for a single injection system (configuration 2) are compared in this thesis. The effects of blowing ratio, spanwise hole spacing, hole angle orientation, and streamwise position (x/d) are discussed in reference to measurements of spanwise-averaged adiabatic effectiveness, iso-energetic Stanton number and Stanton number for 0 approximately equal to 1.5 obtained downstream of both one row of holes and two staggered rows of holes. Results indicate that effectiveness depends mostly on four parameters: simple or compound angle injection, spanwise hole spacing, one or two rows of holes, and blowing ratio. Results show that for a specified blowing ratio, for all configurations tested to date, spanwise-averaged adiabatic effectiveness is greatest at lower x/d values but decreases with streamwise development as the injectant is convected downstream. The rate of spanwise-averaged adiabatic effectiveness decrease is dependent on the blowing ratio, and mostly a result of lift-off of the injectant from the test surface at x/d values less than about 20. At larger x/d, spanwise-averaged adiabatic effectiveness values generally increase with blowing ratio mostly because of grater amounts of injectant along the test surface,. Results also show that the iso-energetic Stanton number ratio lies between 1 and 1.35 for all cases studied and generally increases with blowing ratio for a given x/d."],"dc:description.uri":["http://archive.org/details/heattransferdiab1094528258"],"dc:format.extent":["224 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/28258"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Compound angle injection","Simple angle injection","Film cooling","Turbulent boundary layer"],"dc:title":["Heat transfer, adiabatic effectiveness and injectant distributions downstream of single rows and two staggered rows of film-cooling holes with simple and compound angles"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:32:58Z"}