{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28259"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28259","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Heat transfer enhancement due to bubble pumping in FC-72 near the saturation temperature.","abstract":"The use of boiling heat transfer in the liquid immersion cooling of electronic components has always been hampered by the excessive superheat necessary to initiate nucleation in the fluorinated hydrocarbons used as dielectric cooling fluids. In an attempt to overcome some of these difficulties, an experimental study of the effects of nucleate pooling boiling, on the heat transfer from surface near the boiling surface was conducted. An experimental chamber was constructed which had a column of four horizontal wires spaced 2.5 cm vertically from each other. The lowest wire was progressively heated from the natural convection region through the nucleate boiling region. A study was made of the effects of the boiling wake from the lowest wire on heat transfer from the upper wires. Under certain conditions heat transfer enhancements of up to 30% were obtained.","abstract_html":"The use of boiling heat transfer in the liquid immersion cooling of electronic components has always been hampered by the excessive superheat necessary to initiate nucleation in the fluorinated hydrocarbons used as dielectric cooling fluids. In an attempt to overcome some of these difficulties, an experimental study of the effects of nucleate pooling boiling, on the heat transfer from surface near the boiling surface was conducted. An experimental chamber was constructed which had a column of four horizontal wires spaced 2.5 cm vertically from each other. The lowest wire was progressively heated from the natural convection region through the nucleate boiling region. A study was made of the effects of the boiling wake from the lowest wire on heat transfer from the upper wires. Under certain conditions heat transfer enhancements of up to 30% were obtained.","abstract_has_math":false,"creators":["Eren, Ali Sükrü"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Kelleher, Matthew"],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991-03","date_published":"1991-03","updated_at":"2026-11-21T23:38:55Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28259","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28259","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F28259","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28259","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kelleher, Matthew"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Eren, Ali Sükrü"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:32:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:32:05Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["boiling cooling","vertical channel","triggering||horizontally parallel placed||chromel wires"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28259"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The use of boiling heat transfer in the liquid immersion cooling of electronic components has always been hampered by the excessive superheat necessary to initiate nucleation in the fluorinated hydrocarbons used as dielectric cooling fluids. In an attempt to overcome some of these difficulties, an experimental study of the effects of nucleate pooling boiling, on the heat transfer from surface near the boiling surface was conducted. An experimental chamber was constructed which had a column of four horizontal wires spaced 2.5 cm vertically from each other. The lowest wire was progressively heated from the natural convection region through the nucleate boiling region. A study was made of the effects of the boiling wake from the lowest wire on heat transfer from the upper wires. Under certain conditions heat transfer enhancements of up to 30% were obtained."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/heattransferenha1094528259"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["72 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Heat transfer enhancement due to bubble pumping in FC-72 near the saturation temperature."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Junior Grade, Turkish Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kelleher, Matthew"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Eren, Ali Sükrü"],"dc:date.accessioned":["2013-02-15T23:32:05Z"],"dc:date.available":["2013-02-15T23:32:05Z"],"dc:date.issued":["1991-03"],"dc:description.abstract":["The use of boiling heat transfer in the liquid immersion cooling of electronic components has always been hampered by the excessive superheat necessary to initiate nucleation in the fluorinated hydrocarbons used as dielectric cooling fluids. In an attempt to overcome some of these difficulties, an experimental study of the effects of nucleate pooling boiling, on the heat transfer from surface near the boiling surface was conducted. An experimental chamber was constructed which had a column of four horizontal wires spaced 2.5 cm vertically from each other. The lowest wire was progressively heated from the natural convection region through the nucleate boiling region. A study was made of the effects of the boiling wake from the lowest wire on heat transfer from the upper wires. Under certain conditions heat transfer enhancements of up to 30% were obtained."],"dc:description.uri":["http://archive.org/details/heattransferenha1094528259"],"dc:format.extent":["72 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/28259"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["boiling cooling","vertical channel","triggering||horizontally parallel placed||chromel wires"],"dc:title":["Heat transfer enhancement due to bubble pumping in FC-72 near the saturation temperature."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Junior Grade, Turkish Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:38:55Z"}