{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28309"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28309","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Investigation of the effects of solid rocket motor propellant composition on plume signature","abstract":"Three propellants with aluminum/silicon weight percentages of 18/0%, 13.5/4.5%, and 12/6% were fired in a subscale motor to determine if the plume infrared signature could be reduced without a significant loss in specific impulse. Spectral measurements from 2.5 to 5.5 micrometers and thermal measurements from 3.5 to 5.0 micrometers were made. Plume particle size measurements showed that only particles with small diameters (less than 1.93 micrometers) were present with any significant volume. Replacing a portion of the aluminum in a highly metallized solid propellant with silicon was found to eliminate the Al2O3 in favor of SiO2 and Al6SiOl3, without any change in particulate mass concentration or any large change in particle size distribution. These particulates were found to have significantly lower absorptivity than Al2O3. An additional investigation was conducted to determine the particle size distribution at the nozzle entrance. Malvern ensemble scattering, phase-Doppler single particle scattering and laser transmittance measurements made through windows in the combustion chamber at the nozzle entrance indicated that large particles were present (to 250 micrometers). However, most of the mass of the particles was contained in particles with diameters smaller than 5 micrometers. Approximate calculations made with the measured data showed that if 100 micrometers particles are present with the smoke (particles with diameters less than 2 micrometers) they could account for only approximately 10% of the article volume","abstract_html":"Three propellants with aluminum/silicon weight percentages of 18/0%, 13.5/4.5%, and 12/6% were fired in a subscale motor to determine if the plume infrared signature could be reduced without a significant loss in specific impulse. Spectral measurements from 2.5 to 5.5 micrometers and thermal measurements from 3.5 to 5.0 micrometers were made. Plume particle size measurements showed that only particles with small diameters (less than 1.93 micrometers) were present with any significant volume. Replacing a portion of the aluminum in a highly metallized solid propellant with silicon was found to eliminate the Al2O3 in favor of SiO2 and Al6SiOl3, without any change in particulate mass concentration or any large change in particle size distribution. These particulates were found to have significantly lower absorptivity than Al2O3. An additional investigation was conducted to determine the particle size distribution at the nozzle entrance. Malvern ensemble scattering, phase-Doppler single particle scattering and laser transmittance measurements made through windows in the combustion chamber at the nozzle entrance indicated that large particles were present (to 250 micrometers). However, most of the mass of the particles was contained in particles with diameters smaller than 5 micrometers. Approximate calculations made with the measured data showed that if 100 micrometers particles are present with the smoke (particles with diameters less than 2 micrometers) they could account for only approximately 10% of the article volume","abstract_has_math":false,"creators":["Snaza, Clay J."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Astronautical Engineering","degree_level":"Masters","degree_discipline":"Astronautical Engineering","degree_department":"Astronautical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Netzer, David W."],"committee_chairs":[],"committee_members":["Newberry, Conrad F."],"year":1994,"date_issued":"1994-06","date_published":"1994-06","updated_at":"2026-11-21T23:42:21Z","subjects":["Astronautical Engineering"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28309","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28309","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28309","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Netzer, David W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Newberry, Conrad F."]},{"key":"dc:contributor.department","label":"Department","values":["Astronautical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Snaza, Clay J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:32:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:32:26Z"]},{"key":"dc:date.issued","label":"Date","values":["1994-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Astronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Astronautical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28309"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Three propellants with aluminum/silicon weight percentages of 18/0%, 13.5/4.5%, and 12/6% were fired in a subscale motor to determine if the plume infrared signature could be reduced without a significant loss in specific impulse. Spectral measurements from 2.5 to 5.5 micrometers and thermal measurements from 3.5 to 5.0 micrometers were made. Plume particle size measurements showed that only particles with small diameters (less than 1.93 micrometers) were present with any significant volume. Replacing a portion of the aluminum in a highly metallized solid propellant with silicon was found to eliminate the Al2O3 in favor of SiO2 and Al6SiOl3, without any change in particulate mass concentration or any large change in particle size distribution. These particulates were found to have significantly lower absorptivity than Al2O3. An additional investigation was conducted to determine the particle size distribution at the nozzle entrance. Malvern ensemble scattering, phase-Doppler single particle scattering and laser transmittance measurements made through windows in the combustion chamber at the nozzle entrance indicated that large particles were present (to 250 micrometers). However, most of the mass of the particles was contained in particles with diameters smaller than 5 micrometers. Approximate calculations made with the measured data showed that if 100 micrometers particles are present with the smoke (particles with diameters less than 2 micrometers) they could account for only approximately 10% of the article volume"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/investigationofe1094528309"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["57 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Investigation of the effects of solid rocket motor propellant composition on plume signature"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Netzer, David W."],"dc:contributor.committeemember":["Newberry, Conrad F."],"dc:contributor.department":["Astronautical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Snaza, Clay J."],"dc:date.accessioned":["2013-02-15T23:32:26Z"],"dc:date.available":["2013-02-15T23:32:26Z"],"dc:date.issued":["1994-06"],"dc:description.abstract":["Three propellants with aluminum/silicon weight percentages of 18/0%, 13.5/4.5%, and 12/6% were fired in a subscale motor to determine if the plume infrared signature could be reduced without a significant loss in specific impulse. Spectral measurements from 2.5 to 5.5 micrometers and thermal measurements from 3.5 to 5.0 micrometers were made. Plume particle size measurements showed that only particles with small diameters (less than 1.93 micrometers) were present with any significant volume. Replacing a portion of the aluminum in a highly metallized solid propellant with silicon was found to eliminate the Al2O3 in favor of SiO2 and Al6SiOl3, without any change in particulate mass concentration or any large change in particle size distribution. These particulates were found to have significantly lower absorptivity than Al2O3. An additional investigation was conducted to determine the particle size distribution at the nozzle entrance. Malvern ensemble scattering, phase-Doppler single particle scattering and laser transmittance measurements made through windows in the combustion chamber at the nozzle entrance indicated that large particles were present (to 250 micrometers). However, most of the mass of the particles was contained in particles with diameters smaller than 5 micrometers. Approximate calculations made with the measured data showed that if 100 micrometers particles are present with the smoke (particles with diameters less than 2 micrometers) they could account for only approximately 10% of the article volume"],"dc:description.uri":["http://archive.org/details/investigationofe1094528309"],"dc:format.extent":["57 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/28309"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Astronautical Engineering"],"dc:title":["Investigation of the effects of solid rocket motor propellant composition on plume signature"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Astronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Astronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:42:21Z"}