{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28404"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28404","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Nucleate boiling characteristics of R-113 in a small enhanced tube bundle.","abstract":"Heat transfer tests were carried out using a small enhanced tube bundle in a pool of R-l 13. By accurately instrumenting five tubes within the bundle, both the convective and nucleate boiling regions were studied in detail, with emphasis on the 'bundle' effect (i.e. the effect of lower tubes in operation on upper tubes within the bundle). In addition, the effect of surface history and pool height on nucleation site activation/deactivation was studied to see how this affects the overall heat transfer and in particular, the shape of the hysteresis loop. From the results, recommendations can be made to improve start-up procedures on shipboard AC systems.","abstract_html":"Heat transfer tests were carried out using a small enhanced tube bundle in a pool of R-l 13. By accurately instrumenting five tubes within the bundle, both the convective and nucleate boiling regions were studied in detail, with emphasis on the &#x27;bundle&#x27; effect (i.e. the effect of lower tubes in operation on upper tubes within the bundle). In addition, the effect of surface history and pool height on nucleation site activation/deactivation was studied to see how this affects the overall heat transfer and in particular, the shape of the hysteresis loop. From the results, recommendations can be made to improve start-up procedures on shipboard AC systems.","abstract_has_math":false,"creators":["Chilman, Scott V."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":"Naval Postgraduate School","contributors":[],"advisors":["Marto, P.J.","Memory, Stephen"],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991-09","date_published":"1991-09","updated_at":"2026-11-21T22:35:38Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28404","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28404","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28404","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J.","Memory, Stephen"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Chilman, Scott V."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:33:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:33:02Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Nucleation site activation/deactivation","hysteresis loop","natural convection and nucleate pool boiling regions"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28404"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Heat transfer tests were carried out using a small enhanced tube bundle in a pool of R-l 13. By accurately instrumenting five tubes within the bundle, both the convective and nucleate boiling regions were studied in detail, with emphasis on the 'bundle' effect (i.e. the effect of lower tubes in operation on upper tubes within the bundle). In addition, the effect of surface history and pool height on nucleation site activation/deactivation was studied to see how this affects the overall heat transfer and in particular, the shape of the hysteresis loop. From the results, recommendations can be made to improve start-up procedures on shipboard AC systems."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/nucleateboilingc1094528404"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["176 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Nucleate boiling characteristics of R-113 in a small enhanced tube bundle."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J.","Memory, Stephen"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Chilman, Scott V."],"dc:date.accessioned":["2013-02-15T23:33:02Z"],"dc:date.available":["2013-02-15T23:33:02Z"],"dc:date.issued":["1991-09"],"dc:description.abstract":["Heat transfer tests were carried out using a small enhanced tube bundle in a pool of R-l 13. By accurately instrumenting five tubes within the bundle, both the convective and nucleate boiling regions were studied in detail, with emphasis on the 'bundle' effect (i.e. the effect of lower tubes in operation on upper tubes within the bundle). In addition, the effect of surface history and pool height on nucleation site activation/deactivation was studied to see how this affects the overall heat transfer and in particular, the shape of the hysteresis loop. From the results, recommendations can be made to improve start-up procedures on shipboard AC systems."],"dc:description.uri":["http://archive.org/details/nucleateboilingc1094528404"],"dc:format.extent":["176 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/28404"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Nucleation site activation/deactivation","hysteresis loop","natural convection and nucleate pool boiling regions"],"dc:title":["Nucleate boiling characteristics of R-113 in a small enhanced tube bundle."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:35:38Z"}