{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/28473"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/28473","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Profile sampling dependence of the MLAYER program.","abstract":"The dependence of the predictions of the MLAYER program on the set of heights at which the refractive index value are sampled from a fixed reference profile are analyzed. A refractivity profile with a four-meter evaporation duct is adopted as a reference. Two variable piecewise linear profiles of four and five segments, respectively, are used to approximate the reference profile for MLAYER computations. The sensitivities of the waveguide mode location, the range attenuation rate, and the height-gain function to the changes of the piecewise linear profiles are investigated at the frequencies 3, 6, 10, and 15 GHz. The frequency dependence of the dominant mode for one profile is also studied to investigate the fact that the sensitivity to changes in sampling point location is lower at 6 GHz than at other frequencies. A general rule-of-thumb for the change in range attenuation rate due to a slight change in refractivity is suggested.","abstract_html":"The dependence of the predictions of the MLAYER program on the set of heights at which the refractive index value are sampled from a fixed reference profile are analyzed. A refractivity profile with a four-meter evaporation duct is adopted as a reference. Two variable piecewise linear profiles of four and five segments, respectively, are used to approximate the reference profile for MLAYER computations. The sensitivities of the waveguide mode location, the range attenuation rate, and the height-gain function to the changes of the piecewise linear profiles are investigated at the frequencies 3, 6, 10, and 15 GHz. The frequency dependence of the dominant mode for one profile is also studied to investigate the fact that the sensitivity to changes in sampling point location is lower at 6 GHz than at other frequencies. A general rule-of-thumb for the change in range attenuation rate due to a slight change in refractivity is suggested.","abstract_has_math":false,"creators":["Chang, Ting-Hsun"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S.in Electrical Engineering","degree_level":"Masters","degree_discipline":null,"degree_department":null,"school":"Naval Postgraduate School","contributors":[],"advisors":["Lee, Hung-Mou"],"committee_chairs":[],"committee_members":["Robertson, R. Clark"],"year":1991,"date_issued":"1991-03","date_published":"1991-03","updated_at":"2026-11-21T22:38:09Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/28473","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/28473","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F28473","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F28473","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lee, Hung-Mou"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Robertson, R. Clark"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School"]},{"key":"dc:contributor.school","label":"School","values":["Naval Postgraduate School"]},{"key":"dc:creator","label":"Author","values":["Chang, Ting-Hsun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-02-15T23:33:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-02-15T23:33:28Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S.in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Evaporation duct propagation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/28473"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The dependence of the predictions of the MLAYER program on the set of heights at which the refractive index value are sampled from a fixed reference profile are analyzed. A refractivity profile with a four-meter evaporation duct is adopted as a reference. Two variable piecewise linear profiles of four and five segments, respectively, are used to approximate the reference profile for MLAYER computations. The sensitivities of the waveguide mode location, the range attenuation rate, and the height-gain function to the changes of the piecewise linear profiles are investigated at the frequencies 3, 6, 10, and 15 GHz. The frequency dependence of the dominant mode for one profile is also studied to investigate the fact that the sensitivity to changes in sampling point location is lower at 6 GHz than at other frequencies. A general rule-of-thumb for the change in range attenuation rate due to a slight change in refractivity is suggested."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/profilesamplingd1094528473"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["90 p."]},{"key":"dc:title","label":"Title","values":["Profile sampling dependence of the MLAYER program."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, Taiwan Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Lee, Hung-Mou"],"dc:contributor.committeemember":["Robertson, R. Clark"],"dc:contributor.other":["Naval Postgraduate School"],"dc:contributor.school":["Naval Postgraduate School"],"dc:creator":["Chang, Ting-Hsun"],"dc:date.accessioned":["2013-02-15T23:33:28Z"],"dc:date.available":["2013-02-15T23:33:28Z"],"dc:date.issued":["1991-03"],"dc:description.abstract":["The dependence of the predictions of the MLAYER program on the set of heights at which the refractive index value are sampled from a fixed reference profile are analyzed. A refractivity profile with a four-meter evaporation duct is adopted as a reference. Two variable piecewise linear profiles of four and five segments, respectively, are used to approximate the reference profile for MLAYER computations. The sensitivities of the waveguide mode location, the range attenuation rate, and the height-gain function to the changes of the piecewise linear profiles are investigated at the frequencies 3, 6, 10, and 15 GHz. The frequency dependence of the dominant mode for one profile is also studied to investigate the fact that the sensitivity to changes in sampling point location is lower at 6 GHz than at other frequencies. A general rule-of-thumb for the change in range attenuation rate due to a slight change in refractivity is suggested."],"dc:description.uri":["http://archive.org/details/profilesamplingd1094528473"],"dc:format.extent":["90 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/28473"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Evaporation duct propagation"],"dc:title":["Profile sampling dependence of the MLAYER program."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, Taiwan Navy"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S.in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:38:09Z"}