{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/2859"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/2859","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Optimized recovery of damaged electrical power grids","abstract":"This thesis formulates and solves a mixed-integer program to plan the recovery of an electrical power transmission grid that has been damaged by a natural disaster or terrorist attack. The damage can be extensive and recovery can take weeks or months. An efficient recovery plan that maximizes the utilization of repair resources can help ensure swift restoration of services. The network recovery-planning model is implemented in GAMS (General Algebraic Modeling System) and uses CPLEX as the solver. An electrical grid based on IEEE's 300-bus transmission network is used for testing. To simulate varying degrees of damage to the network, we choose up to 20% of the grid's lines, buses and transformers to be placed out of service. Based on the availability of repair resources, the repair-time horizon and penalties for unserved demand, the model produces a repair schedule that minimizes the cost of power shed. We demonstrate that for a network with up to 8% of its components damaged, the model can produce an optimal recovery plan within 20 minutes on a 2 GHz personal computer. For our largest test-case with 20% of network components damaged, the recovery plan is within 7% of optimal after 1 hour of solver time.","abstract_html":"This thesis formulates and solves a mixed-integer program to plan the recovery of an electrical power transmission grid that has been damaged by a natural disaster or terrorist attack. The damage can be extensive and recovery can take weeks or months. An efficient recovery plan that maximizes the utilization of repair resources can help ensure swift restoration of services. The network recovery-planning model is implemented in GAMS (General Algebraic Modeling System) and uses CPLEX as the solver. An electrical grid based on IEEE&#x27;s 300-bus transmission network is used for testing. To simulate varying degrees of damage to the network, we choose up to 20% of the grid&#x27;s lines, buses and transformers to be placed out of service. Based on the availability of repair resources, the repair-time horizon and penalties for unserved demand, the model produces a repair schedule that minimizes the cost of power shed. We demonstrate that for a network with up to 8% of its components damaged, the model can produce an optimal recovery plan within 20 minutes on a 2 GHz personal computer. For our largest test-case with 20% of network components damaged, the recovery plan is within 7% of optimal after 1 hour of solver time.","abstract_has_math":false,"creators":["Ang, Chee Chien"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Operations Research","degree_level":"Masters","degree_discipline":"Operations Research","degree_department":"Operations Research (OR)","school":null,"contributors":[],"advisors":["Salmeron, Javier","Wood, R. Kevin"],"committee_chairs":[],"committee_members":["Rinaldi, Steven M."],"year":2006,"date_issued":"2006-03","date_published":"2006-03","updated_at":"2026-11-19T06:31:54Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["66268376"],"render_values":[{"text":"66268376","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/2859","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/2859","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F2859","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Salmeron, Javier","Wood, R. Kevin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Rinaldi, Steven M."]},{"key":"dc:contributor.department","label":"Department","values":["Operations Research (OR)"]},{"key":"dc:creator","label":"Author","values":["Ang, Chee Chien"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:36:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:36:28Z"]},{"key":"dc:date.issued","label":"Date","values":["2006-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["58745961-c46a-45ad-ae9c-d139d1ba1041"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Operations Research"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Operations Research"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Electrical Power Grid","Network Recovery","Mixed Integer Programming"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["66268376"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/2859"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis formulates and solves a mixed-integer program to plan the recovery of an electrical power transmission grid that has been damaged by a natural disaster or terrorist attack. The damage can be extensive and recovery can take weeks or months. An efficient recovery plan that maximizes the utilization of repair resources can help ensure swift restoration of services. The network recovery-planning model is implemented in GAMS (General Algebraic Modeling System) and uses CPLEX as the solver. An electrical grid based on IEEE's 300-bus transmission network is used for testing. To simulate varying degrees of damage to the network, we choose up to 20% of the grid's lines, buses and transformers to be placed out of service. Based on the availability of repair resources, the repair-time horizon and penalties for unserved demand, the model produces a repair schedule that minimizes the cost of power shed. We demonstrate that for a network with up to 8% of its components damaged, the model can produce an optimal recovery plan within 20 minutes on a 2 GHz personal computer. For our largest test-case with 20% of network components damaged, the recovery plan is within 7% of optimal after 1 hour of solver time."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/optimizedrecover109452859"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["69 p."]},{"key":"dc:title","label":"Title","values":["Optimized recovery of damaged electrical power grids"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Analyst, DSO National Laboratories, Singapore"]}]}],"canonical_facts":{"dc:contributor.advisor":["Salmeron, Javier","Wood, R. Kevin"],"dc:contributor.committeemember":["Rinaldi, Steven M."],"dc:contributor.department":["Operations Research (OR)"],"dc:creator":["Ang, Chee Chien"],"dc:date.accessioned":["2012-03-14T17:36:28Z"],"dc:date.available":["2012-03-14T17:36:28Z"],"dc:date.issued":["2006-03"],"dc:description.abstract":["This thesis formulates and solves a mixed-integer program to plan the recovery of an electrical power transmission grid that has been damaged by a natural disaster or terrorist attack. The damage can be extensive and recovery can take weeks or months. An efficient recovery plan that maximizes the utilization of repair resources can help ensure swift restoration of services. The network recovery-planning model is implemented in GAMS (General Algebraic Modeling System) and uses CPLEX as the solver. An electrical grid based on IEEE's 300-bus transmission network is used for testing. To simulate varying degrees of damage to the network, we choose up to 20% of the grid's lines, buses and transformers to be placed out of service. Based on the availability of repair resources, the repair-time horizon and penalties for unserved demand, the model produces a repair schedule that minimizes the cost of power shed. We demonstrate that for a network with up to 8% of its components damaged, the model can produce an optimal recovery plan within 20 minutes on a 2 GHz personal computer. For our largest test-case with 20% of network components damaged, the recovery plan is within 7% of optimal after 1 hour of solver time."],"dc:description.uri":["http://archive.org/details/optimizedrecover109452859"],"dc:format.extent":["69 p."],"dc:identifier.oclc":["66268376"],"dc:identifier.uri":["https://hdl.handle.net/10945/2859"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["58745961-c46a-45ad-ae9c-d139d1ba1041"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["Electrical Power Grid","Network Recovery","Mixed Integer Programming"],"dc:title":["Optimized recovery of damaged electrical power grids"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Analyst, DSO National Laboratories, Singapore"],"thesis:degree_discipline":["Operations Research"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Operations Research"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:31:54Z"}