{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/3047"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/3047","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A position tracking system using MARG sensors","abstract":"The objective of this thesis was to further the development of a personal position tracking system using MARG sensors. This work advanced the method by which distance and heading were calculated of an individual wearing one MARG sensor on his/her foot when moving about under normal walking conditions. Data was collected from the foot-mounted sensor while walking a straight-line path, a square path, and climbing stairs. The corresponding data from these activities was then used in a Matlab program to determine a computed position. The Matlab program employed a technique that reset the accelerometer error during the stance phase of the gait cycle. It also utilized a gait detection algorithm based on the magnitude of angular rate and the number of samples above/below threshold to establish the periods of the stance phase and the swing phase. Experimental results from various testing scenarios showed that it is feasible to track position of a person.","abstract_html":"The objective of this thesis was to further the development of a personal position tracking system using MARG sensors. This work advanced the method by which distance and heading were calculated of an individual wearing one MARG sensor on his/her foot when moving about under normal walking conditions. Data was collected from the foot-mounted sensor while walking a straight-line path, a square path, and climbing stairs. The corresponding data from these activities was then used in a Matlab program to determine a computed position. The Matlab program employed a technique that reset the accelerometer error during the stance phase of the gait cycle. It also utilized a gait detection algorithm based on the magnitude of angular rate and the number of samples above/below threshold to establish the periods of the stance phase and the swing phase. Experimental results from various testing scenarios showed that it is feasible to track position of a person.","abstract_has_math":false,"creators":["Um, Miryung"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Yun, Xiaoping"],"committee_chairs":[],"committee_members":["Ateshian, Peter"],"year":2007,"date_issued":"2007-12","date_published":"2007-12","updated_at":"2026-11-19T06:31:54Z","subjects":["Electrical engineering","Biomechanics","Magnetometers"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["191698409"],"render_values":[{"text":"191698409","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/3047","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/3047","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F3047","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yun, Xiaoping"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ateshian, Peter"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Um, Miryung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:37:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:37:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2007-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electrical engineering","Biomechanics","Magnetometers"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["191698409"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/3047"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this thesis was to further the development of a personal position tracking system using MARG sensors. This work advanced the method by which distance and heading were calculated of an individual wearing one MARG sensor on his/her foot when moving about under normal walking conditions. Data was collected from the foot-mounted sensor while walking a straight-line path, a square path, and climbing stairs. The corresponding data from these activities was then used in a Matlab program to determine a computed position. The Matlab program employed a technique that reset the accelerometer error during the stance phase of the gait cycle. It also utilized a gait detection algorithm based on the magnitude of angular rate and the number of samples above/below threshold to establish the periods of the stance phase and the swing phase. Experimental results from various testing scenarios showed that it is feasible to track position of a person."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/apositiontrackin109453047"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xvi, 59 p. : col. ill. ;"]},{"key":"dc:title","label":"Title","values":["A position tracking system using MARG sensors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Korean Army author."]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yun, Xiaoping"],"dc:contributor.committeemember":["Ateshian, Peter"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Um, Miryung"],"dc:date.accessioned":["2012-03-14T17:37:05Z"],"dc:date.available":["2012-03-14T17:37:05Z"],"dc:date.issued":["2007-12"],"dc:description.abstract":["The objective of this thesis was to further the development of a personal position tracking system using MARG sensors. This work advanced the method by which distance and heading were calculated of an individual wearing one MARG sensor on his/her foot when moving about under normal walking conditions. Data was collected from the foot-mounted sensor while walking a straight-line path, a square path, and climbing stairs. The corresponding data from these activities was then used in a Matlab program to determine a computed position. The Matlab program employed a technique that reset the accelerometer error during the stance phase of the gait cycle. It also utilized a gait detection algorithm based on the magnitude of angular rate and the number of samples above/below threshold to establish the periods of the stance phase and the swing phase. Experimental results from various testing scenarios showed that it is feasible to track position of a person."],"dc:description.uri":["http://archive.org/details/apositiontrackin109453047"],"dc:format.extent":["xvi, 59 p. : col. ill. ;"],"dc:identifier.oclc":["191698409"],"dc:identifier.uri":["https://hdl.handle.net/10945/3047"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Electrical engineering","Biomechanics","Magnetometers"],"dc:title":["A position tracking system using MARG sensors"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Korean Army author."],"local:etd.verified":["no"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:31:54Z"}