{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/30529"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/30529","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Response of dual-layered structures subjected to shock pressure wave","abstract":"The response of coated, metallic structures subjected to shock pressure waves is studied. The coating is either an elastic material or nearly incompressible rubber of variable stiffness separating the structure from an air or water medium. The stress, nodal velocity, and internal energy of the coated structure are compared to a system without a coating (homogeneous system) to examine the effect of various coating types and configurations on the response of the structure to shock conditions. The results show that a mismatch of impedance, pc sub o, between the coating and structure governs the degree of energy exchange between the coating and structure at the interface. The impedance mismatch between the structure and a rubber coating at the threshold value is termed the critical difference. If the impedance mismatch exceeds the critical difference, the dynamic response will be more adverse. A softer coating generally has a smaller impedance and tends to concentrate stress wave energy in the underlying structure.","abstract_html":"The response of coated, metallic structures subjected to shock pressure waves is studied. The coating is either an elastic material or nearly incompressible rubber of variable stiffness separating the structure from an air or water medium. The stress, nodal velocity, and internal energy of the coated structure are compared to a system without a coating (homogeneous system) to examine the effect of various coating types and configurations on the response of the structure to shock conditions. The results show that a mismatch of impedance, pc sub o, between the coating and structure governs the degree of energy exchange between the coating and structure at the interface. The impedance mismatch between the structure and a rubber coating at the threshold value is termed the critical difference. If the impedance mismatch exceeds the critical difference, the dynamic response will be more adverse. A softer coating generally has a smaller impedance and tends to concentrate stress wave energy in the underlying structure.","abstract_has_math":false,"creators":["Brasek, Thomas Peyton"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Kwon, Young"],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994-12","date_published":"1994-12","updated_at":"2026-11-21T23:43:05Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/30529","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/30529","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F30529","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F30529","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kwon, Young"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Brasek, Thomas Peyton"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December, 1994"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-11T21:53:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-11T21:53:18Z"]},{"key":"dc:date.issued","label":"Date","values":["1994-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["NA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/30529"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The response of coated, metallic structures subjected to shock pressure waves is studied. The coating is either an elastic material or nearly incompressible rubber of variable stiffness separating the structure from an air or water medium. The stress, nodal velocity, and internal energy of the coated structure are compared to a system without a coating (homogeneous system) to examine the effect of various coating types and configurations on the response of the structure to shock conditions. The results show that a mismatch of impedance, pc sub o, between the coating and structure governs the degree of energy exchange between the coating and structure at the interface. The impedance mismatch between the structure and a rubber coating at the threshold value is termed the critical difference. If the impedance mismatch exceeds the critical difference, the dynamic response will be more adverse. A softer coating generally has a smaller impedance and tends to concentrate stress wave energy in the underlying structure."]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["NA"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/responseofdualla1094530529"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["73 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Response of dual-layered structures subjected to shock pressure wave"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["NA"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (U.S.N.) author."]}]}],"canonical_facts":{"dc:contributor.advisor":["Kwon, Young"],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Brasek, Thomas Peyton"],"dc:date":["December, 1994"],"dc:date.accessioned":["2013-04-11T21:53:18Z"],"dc:date.available":["2013-04-11T21:53:18Z"],"dc:date.issued":["1994-12"],"dc:description.abstract":["The response of coated, metallic structures subjected to shock pressure waves is studied. The coating is either an elastic material or nearly incompressible rubber of variable stiffness separating the structure from an air or water medium. The stress, nodal velocity, and internal energy of the coated structure are compared to a system without a coating (homogeneous system) to examine the effect of various coating types and configurations on the response of the structure to shock conditions. The results show that a mismatch of impedance, pc sub o, between the coating and structure governs the degree of energy exchange between the coating and structure at the interface. The impedance mismatch between the structure and a rubber coating at the threshold value is termed the critical difference. If the impedance mismatch exceeds the critical difference, the dynamic response will be more adverse. A softer coating generally has a smaller impedance and tends to concentrate stress wave energy in the underlying structure."],"dc:description.award":["NA"],"dc:description.sponsorship":["NA"],"dc:description.uri":["http://archive.org/details/responseofdualla1094530529"],"dc:format.extent":["73 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/30529"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:subject.keyword":["NA"],"dc:title":["Response of dual-layered structures subjected to shock pressure wave"],"dc:title.alternative":["NA"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (U.S.N.) author."],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:43:05Z"}