{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/30645"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/30645","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A computational and experimental study of flush heat sources in liquids","abstract":"A numerical investigation of two-dimensional natural convection flow and heat transfer from a substrate-mounted flush heat source immersed in a liquid-filled square enclosure was conducted. The study is relevant to direct liquid-immersion cooling of electronic-components. A control volume based finite-difference model that accounts for conduction heat transfer within the substrate and heat source and the coupled natural convection in the fluid was utilized. Numerical predictions were obtained for a wide range of Rayleigh and Prandtl numbers, substrate to fluid and heat source to fluid thermal conductivity ratios and other geometrical parameters that may be encountered in practice. An increase in Rayleigh number lead to more vigorous flow and promoted cooling. No noticeable effect on the nondimensional temperature was observed when changing the Prandt number from 7 to 100. Little reduction in maximum temperatures was observed when substrate and component to fluid thermal conductivity ratios were increased beyond 10 and 25, respectively. Component to substrate width ratio change from .25 to .999 resulted in approximately linear decrease in the maximum temperature. A companion experimental study of three- dimensional natural convection transport from a flush mounted array of heat sources in water was also conducted. Computer temperatures compared favorably to appropriate experimental data.","abstract_html":"A numerical investigation of two-dimensional natural convection flow and heat transfer from a substrate-mounted flush heat source immersed in a liquid-filled square enclosure was conducted. The study is relevant to direct liquid-immersion cooling of electronic-components. A control volume based finite-difference model that accounts for conduction heat transfer within the substrate and heat source and the coupled natural convection in the fluid was utilized. Numerical predictions were obtained for a wide range of Rayleigh and Prandtl numbers, substrate to fluid and heat source to fluid thermal conductivity ratios and other geometrical parameters that may be encountered in practice. An increase in Rayleigh number lead to more vigorous flow and promoted cooling. No noticeable effect on the nondimensional temperature was observed when changing the Prandt number from 7 to 100. Little reduction in maximum temperatures was observed when substrate and component to fluid thermal conductivity ratios were increased beyond 10 and 25, respectively. Component to substrate width ratio change from .25 to .999 resulted in approximately linear decrease in the maximum temperature. A companion experimental study of three- dimensional natural convection transport from a flush mounted array of heat sources in water was also conducted. Computer temperatures compared favorably to appropriate experimental data.","abstract_has_math":false,"creators":["Haukenes, Larry Olaf"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering and Degree of Mechanical Engineer","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Sathe, Sanjeev","Joshi, Yogendra"],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990-06","date_published":"1990-06","updated_at":"2026-11-21T23:32:32Z","subjects":["Heat,Transmission","Fluid mechanics."],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/30645","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/30645","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F30645","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sathe, Sanjeev","Joshi, Yogendra"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Haukenes, Larry Olaf"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 1990"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-11T22:14:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-11T22:14:49Z"]},{"key":"dc:date.issued","label":"Date","values":["1990-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering","Mechanical Engineer"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters","Professional Degree"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering and Degree of Mechanical Engineer"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Electronic Cooling","Liquid Immersion","Natural Convection","Numerical Heat Transfer"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Heat,Transmission","Fluid mechanics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/30645"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A numerical investigation of two-dimensional natural convection flow and heat transfer from a substrate-mounted flush heat source immersed in a liquid-filled square enclosure was conducted. The study is relevant to direct liquid-immersion cooling of electronic-components. A control volume based finite-difference model that accounts for conduction heat transfer within the substrate and heat source and the coupled natural convection in the fluid was utilized. Numerical predictions were obtained for a wide range of Rayleigh and Prandtl numbers, substrate to fluid and heat source to fluid thermal conductivity ratios and other geometrical parameters that may be encountered in practice. An increase in Rayleigh number lead to more vigorous flow and promoted cooling. No noticeable effect on the nondimensional temperature was observed when changing the Prandt number from 7 to 100. Little reduction in maximum temperatures was observed when substrate and component to fluid thermal conductivity ratios were increased beyond 10 and 25, respectively. Component to substrate width ratio change from .25 to .999 resulted in approximately linear decrease in the maximum temperature. A companion experimental study of three- dimensional natural convection transport from a flush mounted array of heat sources in water was also conducted. Computer temperatures compared favorably to appropriate experimental data."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/acomputationalnd1094530645"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 135 p. ; ill."]},{"key":"dc:title","label":"Title","values":["A computational and experimental study of flush heat sources in liquids"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sathe, Sanjeev","Joshi, Yogendra"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Haukenes, Larry Olaf"],"dc:date":["June 1990"],"dc:date.accessioned":["2013-04-11T22:14:49Z"],"dc:date.available":["2013-04-11T22:14:49Z"],"dc:date.issued":["1990-06"],"dc:description.abstract":["A numerical investigation of two-dimensional natural convection flow and heat transfer from a substrate-mounted flush heat source immersed in a liquid-filled square enclosure was conducted. The study is relevant to direct liquid-immersion cooling of electronic-components. A control volume based finite-difference model that accounts for conduction heat transfer within the substrate and heat source and the coupled natural convection in the fluid was utilized. Numerical predictions were obtained for a wide range of Rayleigh and Prandtl numbers, substrate to fluid and heat source to fluid thermal conductivity ratios and other geometrical parameters that may be encountered in practice. An increase in Rayleigh number lead to more vigorous flow and promoted cooling. No noticeable effect on the nondimensional temperature was observed when changing the Prandt number from 7 to 100. Little reduction in maximum temperatures was observed when substrate and component to fluid thermal conductivity ratios were increased beyond 10 and 25, respectively. Component to substrate width ratio change from .25 to .999 resulted in approximately linear decrease in the maximum temperature. A companion experimental study of three- dimensional natural convection transport from a flush mounted array of heat sources in water was also conducted. Computer temperatures compared favorably to appropriate experimental data."],"dc:description.uri":["http://archive.org/details/acomputationalnd1094530645"],"dc:format.extent":["ix, 135 p. ; ill."],"dc:identifier.uri":["https://hdl.handle.net/10945/30645"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Electronic Cooling","Liquid Immersion","Natural Convection","Numerical Heat Transfer"],"dc:subject.lcsh":["Heat,Transmission","Fluid mechanics."],"dc:title":["A computational and experimental study of flush heat sources in liquids"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering","Mechanical Engineer"],"thesis:degree_level":["Masters","Professional Degree"],"thesis:degree_name":["M.S. in Mechanical Engineering and Degree of Mechanical Engineer"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:32:32Z"}