{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/31562"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/31562","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Effect of fin height on film condensation of steam on stainless steel integral-fin tubes","abstract":"Condensation heat transfer performance on a series of horizontal stainless-steel integral-fin tubes was experimentally studied at both atmospheric and vacuum pressure conditions to examine the effects of fin height on tubes of low thermal conductivity. Eight tubes with rectangular fin heights ranging from 0.16 to 1.42 mm and a smooth tube were tested. The fin thickness and spacing and tube inside and root diameters were kept constant at 1.0, 1.5, 13.1, and 14.2 mm respectively. The overall heat transfer coefficient was determined from experimentation and the outside heat transfer coefficient was then determined using the modified Wilson plot technique. A fin height of approximately 0.30 mm provided the maximum heat transfer at both vacuum and atmospheric conditions. Heat transfer performance declined steadily for further increases in fin height. The experimental results were compared to the predictions of the Beatty and Katz and Briggs and Rose models. Neither model satisfactorily predicted performance for the full range of fin heights tested.","abstract_html":"Condensation heat transfer performance on a series of horizontal stainless-steel integral-fin tubes was experimentally studied at both atmospheric and vacuum pressure conditions to examine the effects of fin height on tubes of low thermal conductivity. Eight tubes with rectangular fin heights ranging from 0.16 to 1.42 mm and a smooth tube were tested. The fin thickness and spacing and tube inside and root diameters were kept constant at 1.0, 1.5, 13.1, and 14.2 mm respectively. The overall heat transfer coefficient was determined from experimentation and the outside heat transfer coefficient was then determined using the modified Wilson plot technique. A fin height of approximately 0.30 mm provided the maximum heat transfer at both vacuum and atmospheric conditions. Heat transfer performance declined steadily for further increases in fin height. The experimental results were compared to the predictions of the Beatty and Katz and Briggs and Rose models. Neither model satisfactorily predicted performance for the full range of fin heights tested.","abstract_has_math":false,"creators":["Incheck, George A."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995-03","date_published":"1995-03","updated_at":"2026-11-26T00:13:06Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/31562","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/31562","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F31562","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F31562","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Incheck, George A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March 1995"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-29T22:51:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-29T22:51:29Z"]},{"key":"dc:date.issued","label":"Date","values":["1995-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/31562"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Condensation heat transfer performance on a series of horizontal stainless-steel integral-fin tubes was experimentally studied at both atmospheric and vacuum pressure conditions to examine the effects of fin height on tubes of low thermal conductivity. Eight tubes with rectangular fin heights ranging from 0.16 to 1.42 mm and a smooth tube were tested. The fin thickness and spacing and tube inside and root diameters were kept constant at 1.0, 1.5, 13.1, and 14.2 mm respectively. The overall heat transfer coefficient was determined from experimentation and the outside heat transfer coefficient was then determined using the modified Wilson plot technique. A fin height of approximately 0.30 mm provided the maximum heat transfer at both vacuum and atmospheric conditions. Heat transfer performance declined steadily for further increases in fin height. The experimental results were compared to the predictions of the Beatty and Katz and Briggs and Rose models. Neither model satisfactorily predicted performance for the full range of fin heights tested."]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["NA"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/effectoffinheigh1094531562"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["308 p."]},{"key":"dc:title","label":"Title","values":["Effect of fin height on film condensation of steam on stainless steel integral-fin tubes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (U.S.N.) author."]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Incheck, George A."],"dc:date":["March 1995"],"dc:date.accessioned":["2013-04-29T22:51:29Z"],"dc:date.available":["2013-04-29T22:51:29Z"],"dc:date.issued":["1995-03"],"dc:description.abstract":["Condensation heat transfer performance on a series of horizontal stainless-steel integral-fin tubes was experimentally studied at both atmospheric and vacuum pressure conditions to examine the effects of fin height on tubes of low thermal conductivity. Eight tubes with rectangular fin heights ranging from 0.16 to 1.42 mm and a smooth tube were tested. The fin thickness and spacing and tube inside and root diameters were kept constant at 1.0, 1.5, 13.1, and 14.2 mm respectively. The overall heat transfer coefficient was determined from experimentation and the outside heat transfer coefficient was then determined using the modified Wilson plot technique. A fin height of approximately 0.30 mm provided the maximum heat transfer at both vacuum and atmospheric conditions. Heat transfer performance declined steadily for further increases in fin height. The experimental results were compared to the predictions of the Beatty and Katz and Briggs and Rose models. Neither model satisfactorily predicted performance for the full range of fin heights tested."],"dc:description.award":["NA"],"dc:description.sponsorship":["NA"],"dc:description.uri":["http://archive.org/details/effectoffinheigh1094531562"],"dc:format.extent":["308 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/31562"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:title":["Effect of fin height on film condensation of steam on stainless steel integral-fin tubes"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (U.S.N.) author."],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:13:06Z"}