{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/32093"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/32093","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The effect of a novel coating technique on filmwise and dropwise condensation of steam on horizontal tubes","abstract":"Steam condensation heat transfer on smooth horizontal tubes and on a Korodense horizontal tube was experimentally studied at atmospheric pressure and at vacuum. The overall heat transfer coefficient was measured and the outside heat transfer coefficient was determined from the modified Wilson Plot Technique. A hydrophobic coating of a self-assembling monolayer (SAM) with a composition of HS(CH2)15 CH3 promoted excellent dropwise condensation (DWC) on tubes. Coexisting strips with varying widths of filmwise condensation (FWC) and DWC, but at a constant area ratio of 50%, were also investigated.","abstract_html":"Steam condensation heat transfer on smooth horizontal tubes and on a Korodense horizontal tube was experimentally studied at atmospheric pressure and at vacuum. The overall heat transfer coefficient was measured and the outside heat transfer coefficient was determined from the modified Wilson Plot Technique. A hydrophobic coating of a self-assembling monolayer (SAM) with a composition of HS(CH2)15 CH3 promoted excellent dropwise condensation (DWC) on tubes. Coexisting strips with varying widths of filmwise condensation (FWC) and DWC, but at a constant area ratio of 50%, were also investigated.","abstract_has_math":false,"creators":["Kilty, Helen P."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Marto, P.J."],"committee_chairs":[],"committee_members":[],"year":1996,"date_issued":"1996-06","date_published":"1996-06","updated_at":"2026-11-21T23:41:17Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/32093","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/32093","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F32093","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marto, P.J."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Kilty, Helen P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June, 1996"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-30T22:05:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-30T22:05:10Z"]},{"key":"dc:date.issued","label":"Date","values":["1996-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/32093"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Steam condensation heat transfer on smooth horizontal tubes and on a Korodense horizontal tube was experimentally studied at atmospheric pressure and at vacuum. The overall heat transfer coefficient was measured and the outside heat transfer coefficient was determined from the modified Wilson Plot Technique. A hydrophobic coating of a self-assembling monolayer (SAM) with a composition of HS(CH2)15 CH3 promoted excellent dropwise condensation (DWC) on tubes. Coexisting strips with varying widths of filmwise condensation (FWC) and DWC, but at a constant area ratio of 50%, were also investigated."]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["NSF-CTS96-24060"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theeffectofnovel1094532093"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["242 p."]},{"key":"dc:title","label":"Title","values":["The effect of a novel coating technique on filmwise and dropwise condensation of steam on horizontal tubes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Coast Guard (U.S.C.G.) author"]}]}],"canonical_facts":{"dc:contributor.advisor":["Marto, P.J."],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Kilty, Helen P."],"dc:date":["June, 1996"],"dc:date.accessioned":["2013-04-30T22:05:10Z"],"dc:date.available":["2013-04-30T22:05:10Z"],"dc:date.issued":["1996-06"],"dc:description.abstract":["Steam condensation heat transfer on smooth horizontal tubes and on a Korodense horizontal tube was experimentally studied at atmospheric pressure and at vacuum. The overall heat transfer coefficient was measured and the outside heat transfer coefficient was determined from the modified Wilson Plot Technique. A hydrophobic coating of a self-assembling monolayer (SAM) with a composition of HS(CH2)15 CH3 promoted excellent dropwise condensation (DWC) on tubes. Coexisting strips with varying widths of filmwise condensation (FWC) and DWC, but at a constant area ratio of 50%, were also investigated."],"dc:description.award":["NA"],"dc:description.sponsorship":["NSF-CTS96-24060"],"dc:description.uri":["http://archive.org/details/theeffectofnovel1094532093"],"dc:format.extent":["242 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/32093"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:title":["The effect of a novel coating technique on filmwise and dropwise condensation of steam on horizontal tubes"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Coast Guard (U.S.C.G.) author"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:41:17Z"}