{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/32167"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/32167","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Resistivity measurement by eddy current methods for real-time monitoring of age hardening in heat treatable alloys","abstract":"In this research, the design of an eddy current sensor system that continuously monitors age hardening during aging of heat treatable alloys was modified to allow for operation at temperatures up to 595 deg C. With two eddy current coils in an impedance bridge circuit, eddy currents are generated in a pure aluminum reference sample standard and an age harden able test sample. The difference in the resistivity of the aging test sample relative to the reference sample results in a bridge unbalance voltage, Delta V sub BCA, which is continuously measured by a multimeter. Also, calibration procedures were developed to allow conversion of the values of delta V sub BCA to a resistivity difference, Delta p=Ptest - Pref, between the test and reference samples. These calibration curves were generated by measuring delta V sub BCA at various temperatures for six test sample standards of known resistivity. The resistivity of the aging sample is determined by adding the known resistivity value for pure aluminum to Delta p. Real-time monitoring of an aging alloy's resistivity may allow heat treaters to integrate this monitoring system with a control system to achieve 'intelligent heat treating'.","abstract_html":"In this research, the design of an eddy current sensor system that continuously monitors age hardening during aging of heat treatable alloys was modified to allow for operation at temperatures up to 595 deg C. With two eddy current coils in an impedance bridge circuit, eddy currents are generated in a pure aluminum reference sample standard and an age harden able test sample. The difference in the resistivity of the aging test sample relative to the reference sample results in a bridge unbalance voltage, Delta V sub BCA, which is continuously measured by a multimeter. Also, calibration procedures were developed to allow conversion of the values of delta V sub BCA to a resistivity difference, Delta p=Ptest - Pref, between the test and reference samples. These calibration curves were generated by measuring delta V sub BCA at various temperatures for six test sample standards of known resistivity. The resistivity of the aging sample is determined by adding the known resistivity value for pure aluminum to Delta p. Real-time monitoring of an aging alloy&#x27;s resistivity may allow heat treaters to integrate this monitoring system with a control system to achieve &#x27;intelligent heat treating&#x27;.","abstract_has_math":false,"creators":["James, Robert Bailey"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["McNelley, T.R."],"committee_chairs":[],"committee_members":[],"year":1996,"date_issued":"1996-03","date_published":"1996-03","updated_at":"2026-11-21T23:32:18Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/32167","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/32167","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F32167","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["McNelley, T.R."]},{"key":"dc:creator","label":"Author","values":["James, Robert Bailey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["March, 1996"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-30T22:05:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-30T22:05:51Z"]},{"key":"dc:date.issued","label":"Date","values":["1996-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/32167"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this research, the design of an eddy current sensor system that continuously monitors age hardening during aging of heat treatable alloys was modified to allow for operation at temperatures up to 595 deg C. With two eddy current coils in an impedance bridge circuit, eddy currents are generated in a pure aluminum reference sample standard and an age harden able test sample. The difference in the resistivity of the aging test sample relative to the reference sample results in a bridge unbalance voltage, Delta V sub BCA, which is continuously measured by a multimeter. Also, calibration procedures were developed to allow conversion of the values of delta V sub BCA to a resistivity difference, Delta p=Ptest - Pref, between the test and reference samples. These calibration curves were generated by measuring delta V sub BCA at various temperatures for six test sample standards of known resistivity. The resistivity of the aging sample is determined by adding the known resistivity value for pure aluminum to Delta p. Real-time monitoring of an aging alloy's resistivity may allow heat treaters to integrate this monitoring system with a control system to achieve 'intelligent heat treating'."]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/resistivitymeasu1094532167"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["57 p."]},{"key":"dc:title","label":"Title","values":["Resistivity measurement by eddy current methods for real-time monitoring of age hardening in heat treatable alloys"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (U.S.N.) author"]}]}],"canonical_facts":{"dc:contributor.advisor":["McNelley, T.R."],"dc:creator":["James, Robert Bailey"],"dc:date":["March, 1996"],"dc:date.accessioned":["2013-04-30T22:05:51Z"],"dc:date.available":["2013-04-30T22:05:51Z"],"dc:date.issued":["1996-03"],"dc:description.abstract":["In this research, the design of an eddy current sensor system that continuously monitors age hardening during aging of heat treatable alloys was modified to allow for operation at temperatures up to 595 deg C. With two eddy current coils in an impedance bridge circuit, eddy currents are generated in a pure aluminum reference sample standard and an age harden able test sample. The difference in the resistivity of the aging test sample relative to the reference sample results in a bridge unbalance voltage, Delta V sub BCA, which is continuously measured by a multimeter. Also, calibration procedures were developed to allow conversion of the values of delta V sub BCA to a resistivity difference, Delta p=Ptest - Pref, between the test and reference samples. These calibration curves were generated by measuring delta V sub BCA at various temperatures for six test sample standards of known resistivity. The resistivity of the aging sample is determined by adding the known resistivity value for pure aluminum to Delta p. Real-time monitoring of an aging alloy's resistivity may allow heat treaters to integrate this monitoring system with a control system to achieve 'intelligent heat treating'."],"dc:description.award":["NA"],"dc:description.uri":["http://archive.org/details/resistivitymeasu1094532167"],"dc:format.extent":["57 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/32167"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:title":["Resistivity measurement by eddy current methods for real-time monitoring of age hardening in heat treatable alloys"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (U.S.N.) author"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:32:18Z"}