{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/32628"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/32628","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Evaluation of a liquid-fueled pulse detonation engine combustor","abstract":"An evaluation of five liquid-fueled pulse detonation engine combustor geometries and flow field conditions was performed over a wide range of equivalence ratios. Particle sizing and spray characterization of commercially available atomizers was conducted to determine the optimum conditions that produced acceptable mass flow and particle size distribution for use in the combustor. The chosen atomizer was installed in the combustor geometries and then analyzed over a range of combustor conditions to measure deflagration to detonation transition (DDT) distances and detonation wave velocities for each condition. Testing was conducted for ambient (100-110 deg F) and higher wall temperatures (>300 deg F) at an operating frequency of 5Hz. It was found that the shortest DDT for JP10 and O2 was achieved using a stepped front-end insert under hot conditions and with a loaded equivalence ratio greater than .75, but less than 1.15.","abstract_html":"An evaluation of five liquid-fueled pulse detonation engine combustor geometries and flow field conditions was performed over a wide range of equivalence ratios. Particle sizing and spray characterization of commercially available atomizers was conducted to determine the optimum conditions that produced acceptable mass flow and particle size distribution for use in the combustor. The chosen atomizer was installed in the combustor geometries and then analyzed over a range of combustor conditions to measure deflagration to detonation transition (DDT) distances and detonation wave velocities for each condition. Testing was conducted for ambient (100-110 deg F) and higher wall temperatures (&gt;300 deg F) at an operating frequency of 5Hz. It was found that the shortest DDT for JP10 and O2 was achieved using a stepped front-end insert under hot conditions and with a loaded equivalence ratio greater than .75, but less than 1.15.","abstract_has_math":false,"creators":["Forster, David L."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Astronautical Engineering","degree_level":"Masters","degree_discipline":"Astronautical Engineering","degree_department":"Astronautical Engineering","school":null,"contributors":[],"advisors":["Brophy, Christopher M.","Netzer, David W."],"committee_chairs":[],"committee_members":["NA"],"year":1998,"date_issued":"1998-12","date_published":"1998-12","updated_at":"2026-11-26T00:22:25Z","subjects":[],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/32628","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/32628","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F32628","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F32628","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brophy, Christopher M.","Netzer, David W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["NA"]},{"key":"dc:contributor.department","label":"Department","values":["Astronautical Engineering"]},{"key":"dc:creator","label":"Author","values":["Forster, David L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-05-06T18:43:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-05-06T18:43:26Z"]},{"key":"dc:date.issued","label":"Date","values":["1998-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Astronautical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["NA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/32628"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An evaluation of five liquid-fueled pulse detonation engine combustor geometries and flow field conditions was performed over a wide range of equivalence ratios. Particle sizing and spray characterization of commercially available atomizers was conducted to determine the optimum conditions that produced acceptable mass flow and particle size distribution for use in the combustor. The chosen atomizer was installed in the combustor geometries and then analyzed over a range of combustor conditions to measure deflagration to detonation transition (DDT) distances and detonation wave velocities for each condition. Testing was conducted for ambient (100-110 deg F) and higher wall temperatures (>300 deg F) at an operating frequency of 5Hz. It was found that the shortest DDT for JP10 and O2 was achieved using a stepped front-end insert under hot conditions and with a loaded equivalence ratio greater than .75, but less than 1.15."]},{"key":"dc:description.award","label":"Dc Description Award","values":["NA"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["N0001498WR20018"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/evaluationofliqu1094532628"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xii, 60 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Evaluation of a liquid-fueled pulse detonation engine combustor"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["NA"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (U.S.N.) author."]}]}],"canonical_facts":{"dc:contributor.advisor":["Brophy, Christopher M.","Netzer, David W."],"dc:contributor.committeemember":["NA"],"dc:contributor.department":["Astronautical Engineering"],"dc:creator":["Forster, David L."],"dc:date.accessioned":["2013-05-06T18:43:26Z"],"dc:date.available":["2013-05-06T18:43:26Z"],"dc:date.issued":["1998-12"],"dc:description.abstract":["An evaluation of five liquid-fueled pulse detonation engine combustor geometries and flow field conditions was performed over a wide range of equivalence ratios. Particle sizing and spray characterization of commercially available atomizers was conducted to determine the optimum conditions that produced acceptable mass flow and particle size distribution for use in the combustor. The chosen atomizer was installed in the combustor geometries and then analyzed over a range of combustor conditions to measure deflagration to detonation transition (DDT) distances and detonation wave velocities for each condition. Testing was conducted for ambient (100-110 deg F) and higher wall temperatures (>300 deg F) at an operating frequency of 5Hz. It was found that the shortest DDT for JP10 and O2 was achieved using a stepped front-end insert under hot conditions and with a loaded equivalence ratio greater than .75, but less than 1.15."],"dc:description.award":["NA"],"dc:description.sponsorship":["N0001498WR20018"],"dc:description.uri":["http://archive.org/details/evaluationofliqu1094532628"],"dc:format.extent":["xii, 60 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/32628"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.keyword":["NA"],"dc:title":["Evaluation of a liquid-fueled pulse detonation engine combustor"],"dc:title.alternative":["NA"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (U.S.N.) author."],"thesis:degree_discipline":["Astronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Astronautical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:22:25Z"}