{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/3327"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/3327","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Costs and benefits of using fuel cells for stationary power generation at Marine Corps Logistics Base Barstow Maintenance Center","abstract":"We compare the costs and benefits of using two types of fuel cell power generation systems versus Southern California Edison to provide the base electricity load for the Marine Corps Logistics Base Barstow Maintenance Center. The results indicate that the break-even point is not likely to occur before year eight and under certain conditions may not occur at all during the 20-year program life cycle. The results do indicate a pollution reduction from fuel cells, but the reduction would not have any measurable impact on the nation's air quality.","abstract_html":"We compare the costs and benefits of using two types of fuel cell power generation systems versus Southern California Edison to provide the base electricity load for the Marine Corps Logistics Base Barstow Maintenance Center. The results indicate that the break-even point is not likely to occur before year eight and under certain conditions may not occur at all during the 20-year program life cycle. The results do indicate a pollution reduction from fuel cells, but the reduction would not have any measurable impact on the nation&#x27;s air quality.","abstract_has_math":false,"creators":["Schendler, Phillip J."],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Management","degree_level":"Masters","degree_discipline":"Management","degree_department":null,"school":null,"contributors":[],"advisors":["Gates, William R.","Henderson, David R."],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002-12","date_published":"2002-12","updated_at":"2026-11-19T06:33:04Z","subjects":["Fuel cells","Electricity","Power resources","Costs"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/3327","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/3327","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F3327","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gates, William R.","Henderson, David R."]},{"key":"dc:creator","label":"Author","values":["Schendler, Phillip J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:38:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:38:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2002-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Management"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Management"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Fuel Cell","Electricity","Power Generation","Barstow","Deregulation","California"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Fuel cells","Electricity","Power resources","Costs"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/3327"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["We compare the costs and benefits of using two types of fuel cell power generation systems versus Southern California Edison to provide the base electricity load for the Marine Corps Logistics Base Barstow Maintenance Center. The results indicate that the break-even point is not likely to occur before year eight and under certain conditions may not occur at all during the 20-year program life cycle. The results do indicate a pollution reduction from fuel cells, but the reduction would not have any measurable impact on the nation's air quality."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/costsndbenefitso109453327"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xvi, 77 p. : ill."]},{"key":"dc:title","label":"Title","values":["Costs and benefits of using fuel cells for stationary power generation at Marine Corps Logistics Base Barstow Maintenance Center"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Marine Corps"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gates, William R.","Henderson, David R."],"dc:creator":["Schendler, Phillip J."],"dc:date.accessioned":["2012-03-14T17:38:01Z"],"dc:date.available":["2012-03-14T17:38:01Z"],"dc:date.issued":["2002-12"],"dc:description.abstract":["We compare the costs and benefits of using two types of fuel cell power generation systems versus Southern California Edison to provide the base electricity load for the Marine Corps Logistics Base Barstow Maintenance Center. The results indicate that the break-even point is not likely to occur before year eight and under certain conditions may not occur at all during the 20-year program life cycle. The results do indicate a pollution reduction from fuel cells, but the reduction would not have any measurable impact on the nation's air quality."],"dc:description.uri":["http://archive.org/details/costsndbenefitso109453327"],"dc:format.extent":["xvi, 77 p. : ill."],"dc:identifier.uri":["https://hdl.handle.net/10945/3327"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Fuel Cell","Electricity","Power Generation","Barstow","Deregulation","California"],"dc:subject.lcsh":["Fuel cells","Electricity","Power resources","Costs"],"dc:title":["Costs and benefits of using fuel cells for stationary power generation at Marine Corps Logistics Base Barstow Maintenance Center"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Marine Corps"],"thesis:degree_discipline":["Management"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Management"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:33:04Z"}