{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/34684"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/34684","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Quantum efficiency as a function of temperature in metal photocathodes","abstract":"Photocathodes, in which light is used to extract electrons from materials by the photoelectric effect, are the principal electron sources for many linear accelerators and Free Electron Lasers (FELs). There is an increasing interest in the use of superconducting radiofrequency electron guns, which work at cryogenic temperatures, and therefore require photocathodes that work at cryogenic temperatures as well. The primary metric used to quantify photocathode performance is the cathodes Quantum Efficiency (QE), which is the ratio between the number of incoming laser photons and outgoing electrons. The objective of this thesis is to measure the QE of metal photocathodes as a function of temperature. To accomplish this, a photocathode test stand capable of varying the temperature of metal samples from 80 K to 400 K was developed, and copper and niobium samples were tested using it. The QE of copper was found to vary by a factor of more than four over this temperature range, while the QE of niobium showed only slight temperature dependence.","abstract_html":"Photocathodes, in which light is used to extract electrons from materials by the photoelectric effect, are the principal electron sources for many linear accelerators and Free Electron Lasers (FELs). There is an increasing interest in the use of superconducting radiofrequency electron guns, which work at cryogenic temperatures, and therefore require photocathodes that work at cryogenic temperatures as well. The primary metric used to quantify photocathode performance is the cathodes Quantum Efficiency (QE), which is the ratio between the number of incoming laser photons and outgoing electrons. The objective of this thesis is to measure the QE of metal photocathodes as a function of temperature. To accomplish this, a photocathode test stand capable of varying the temperature of metal samples from 80 K to 400 K was developed, and copper and niobium samples were tested using it. The QE of copper was found to vary by a factor of more than four over this temperature range, while the QE of niobium showed only slight temperature dependence.","abstract_has_math":false,"creators":["Kara, Abdullah"],"institution":"Monterey, California: Naval Postgraduate School","degree_name":"Master of Science","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Swent, Richard L.","Harris, John R."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-06","date_published":"2013-06","updated_at":"2026-11-19T06:33:31Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/34684","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/34684","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F34684","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F34684","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Swent, Richard L.","Harris, John R."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Kara, Abdullah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Jun-13"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-01T16:51:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-01T16:51:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science","Master of Science in Applied Physics"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Photocathodes","Niobium","Cryogenic Temperature","Quantum Efficiency."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/34684"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Photocathodes, in which light is used to extract electrons from materials by the photoelectric effect, are the principal electron sources for many linear accelerators and Free Electron Lasers (FELs). There is an increasing interest in the use of superconducting radiofrequency electron guns, which work at cryogenic temperatures, and therefore require photocathodes that work at cryogenic temperatures as well. The primary metric used to quantify photocathode performance is the cathodes Quantum Efficiency (QE), which is the ratio between the number of incoming laser photons and outgoing electrons. The objective of this thesis is to measure the QE of metal photocathodes as a function of temperature. To accomplish this, a photocathode test stand capable of varying the temperature of metal samples from 80 K to 400 K was developed, and copper and niobium samples were tested using it. The QE of copper was found to vary by a factor of more than four over this temperature range, while the QE of niobium showed only slight temperature dependence."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/quantumefficienc1094534684"]},{"key":"dc:title","label":"Title","values":["Quantum efficiency as a function of temperature in metal photocathodes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Junior Grade, Turkish Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Swent, Richard L.","Harris, John R."],"dc:contributor.department":["Physics"],"dc:creator":["Kara, Abdullah"],"dc:date":["Jun-13"],"dc:date.accessioned":["2013-08-01T16:51:41Z"],"dc:date.available":["2013-08-01T16:51:41Z"],"dc:date.issued":["2013-06"],"dc:description.abstract":["Photocathodes, in which light is used to extract electrons from materials by the photoelectric effect, are the principal electron sources for many linear accelerators and Free Electron Lasers (FELs). There is an increasing interest in the use of superconducting radiofrequency electron guns, which work at cryogenic temperatures, and therefore require photocathodes that work at cryogenic temperatures as well. The primary metric used to quantify photocathode performance is the cathodes Quantum Efficiency (QE), which is the ratio between the number of incoming laser photons and outgoing electrons. The objective of this thesis is to measure the QE of metal photocathodes as a function of temperature. To accomplish this, a photocathode test stand capable of varying the temperature of metal samples from 80 K to 400 K was developed, and copper and niobium samples were tested using it. The QE of copper was found to vary by a factor of more than four over this temperature range, while the QE of niobium showed only slight temperature dependence."],"dc:description.uri":["http://archive.org/details/quantumefficienc1094534684"],"dc:identifier.uri":["https://hdl.handle.net/10945/34684"],"dc:publisher":["Monterey, California: Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Photocathodes","Niobium","Cryogenic Temperature","Quantum Efficiency."],"dc:title":["Quantum efficiency as a function of temperature in metal photocathodes"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Junior Grade, Turkish Navy"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science","Master of Science in Applied Physics"]},"updated_at":"2026-11-19T06:33:31Z"}