{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/34706"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/34706","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"H-bridge inverter loading analysis for an Energy Management System","abstract":"The Department of the Navy (DON) is committed to reduce its reliance on fossil fuels. Secretary of the Navy Ray Mabus has said, The underlying reasons for reform are clear. Our energy sources are not secure, we need to be more efficient in energy use, and we emit too much carbon. Microgrids utilizing an Energy Management System (EMS) may be the answer to control and route power more efficiently. The power quality achieved from a single phase pulse-width modulation (PWM) voltage source inverter (VSI) (the heart of an EMS) driving an inductive and capacitive (LC) filter with linear and non-linear loads was investigated in this thesis. The open loop PWM waveforms are compared to the power quality standards for ship board power, MIL-STD-1399-300B. This quantifies the performance limits of open loop PWM, which is the simplest control strategy for a single-phase VSI. Closed loop control is shown to be necessary when larger loads are connected to the VSI in order to prevent output voltage sag.","abstract_html":"The Department of the Navy (DON) is committed to reduce its reliance on fossil fuels. Secretary of the Navy Ray Mabus has said, The underlying reasons for reform are clear. Our energy sources are not secure, we need to be more efficient in energy use, and we emit too much carbon. Microgrids utilizing an Energy Management System (EMS) may be the answer to control and route power more efficiently. The power quality achieved from a single phase pulse-width modulation (PWM) voltage source inverter (VSI) (the heart of an EMS) driving an inductive and capacitive (LC) filter with linear and non-linear loads was investigated in this thesis. The open loop PWM waveforms are compared to the power quality standards for ship board power, MIL-STD-1399-300B. This quantifies the performance limits of open loop PWM, which is the simplest control strategy for a single-phase VSI. Closed loop control is shown to be necessary when larger loads are connected to the VSI in order to prevent output voltage sag.","abstract_has_math":false,"creators":["Metzcus, Andrew James"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Julian, Alexander L.","Oriti, Giovanna"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-06","date_published":"2013-06","updated_at":"2026-11-26T00:16:00Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/34706","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/34706","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F34706","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F34706","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Julian, Alexander L.","Oriti, Giovanna"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Metzcus, Andrew James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-01T16:51:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-01T16:51:47Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f4822f3e-2aea-40ad-9b4a-288607743ad7"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88110183-ea50-46f5-b469-809c1418a16d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science","Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Energy Management System","microgrid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/34706"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Department of the Navy (DON) is committed to reduce its reliance on fossil fuels. Secretary of the Navy Ray Mabus has said, The underlying reasons for reform are clear. Our energy sources are not secure, we need to be more efficient in energy use, and we emit too much carbon. Microgrids utilizing an Energy Management System (EMS) may be the answer to control and route power more efficiently. The power quality achieved from a single phase pulse-width modulation (PWM) voltage source inverter (VSI) (the heart of an EMS) driving an inductive and capacitive (LC) filter with linear and non-linear loads was investigated in this thesis. The open loop PWM waveforms are compared to the power quality standards for ship board power, MIL-STD-1399-300B. This quantifies the performance limits of open loop PWM, which is the simplest control strategy for a single-phase VSI. Closed loop control is shown to be necessary when larger loads are connected to the VSI in order to prevent output voltage sag."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/hbridgeinverterl1094534706"]},{"key":"dc:title","label":"Title","values":["H-bridge inverter loading analysis for an Energy Management System"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Julian, Alexander L.","Oriti, Giovanna"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Metzcus, Andrew James"],"dc:date.accessioned":["2013-08-01T16:51:47Z"],"dc:date.available":["2013-08-01T16:51:47Z"],"dc:date.issued":["2013-06"],"dc:description.abstract":["The Department of the Navy (DON) is committed to reduce its reliance on fossil fuels. Secretary of the Navy Ray Mabus has said, The underlying reasons for reform are clear. Our energy sources are not secure, we need to be more efficient in energy use, and we emit too much carbon. Microgrids utilizing an Energy Management System (EMS) may be the answer to control and route power more efficiently. The power quality achieved from a single phase pulse-width modulation (PWM) voltage source inverter (VSI) (the heart of an EMS) driving an inductive and capacitive (LC) filter with linear and non-linear loads was investigated in this thesis. The open loop PWM waveforms are compared to the power quality standards for ship board power, MIL-STD-1399-300B. This quantifies the performance limits of open loop PWM, which is the simplest control strategy for a single-phase VSI. Closed loop control is shown to be necessary when larger loads are connected to the VSI in order to prevent output voltage sag."],"dc:description.uri":["http://archive.org/details/hbridgeinverterl1094534706"],"dc:identifier.uri":["https://hdl.handle.net/10945/34706"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["f4822f3e-2aea-40ad-9b4a-288607743ad7"],"dc:relation.orgunit":["88110183-ea50-46f5-b469-809c1418a16d"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Energy Management System","microgrid"],"dc:title":["H-bridge inverter loading analysis for an Energy Management System"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science","Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:16:00Z"}