{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/34731"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/34731","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Synthetic space vector modulation","abstract":"Alternating current motors are used throughout the fleet because of their rugged construction and nearly maintenance free operation. Since the U.S. Navy is exploring and acting on the possibilities of DC distribution systems, the need exists for simple, reliable three-phase voltage source inverter (VSI) powered induction machines. Until recently, VSIs utilized a pulse width modulation (PWM) scheme controlling the frequency and amplitude of each phase. A novel and simple hardware centered VSI controller was designed, simulated, built and tested featuring a type of space vector modulation (SVM). Design criteria evaluated such as VSI frequency response, switching losses, dead-time and SVM switching sequences were considered. Specifically, modulo-6 and 12 synthetic SVM units were evaluated for future Department of Defense use.","abstract_html":"Alternating current motors are used throughout the fleet because of their rugged construction and nearly maintenance free operation. Since the U.S. Navy is exploring and acting on the possibilities of DC distribution systems, the need exists for simple, reliable three-phase voltage source inverter (VSI) powered induction machines. Until recently, VSIs utilized a pulse width modulation (PWM) scheme controlling the frequency and amplitude of each phase. A novel and simple hardware centered VSI controller was designed, simulated, built and tested featuring a type of space vector modulation (SVM). Design criteria evaluated such as VSI frequency response, switching losses, dead-time and SVM switching sequences were considered. Specifically, modulo-6 and 12 synthetic SVM units were evaluated for future Department of Defense use.","abstract_has_math":false,"creators":["Rogers, L Warren"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Ashton, Robert W."],"committee_chairs":[],"committee_members":["Parker, Andrew A."],"year":2013,"date_issued":"2013-06","date_published":"2013-06","updated_at":"2026-11-26T00:16:25Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/34731","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/34731","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F34731","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F34731","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ashton, Robert W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Parker, Andrew A."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Rogers, L Warren"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Jun-13"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-01T16:51:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-01T16:51:53Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science","Master of Science in Electrical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Modulo-6 Counters","Self-Correcting Counters","Three-Phase Motor Controls","Multiplexed Center-Aligned Pulse Trains","Three-Phase Multiplexer","Voltage Source Inverter","Space Vector Modulation","Synthetic Space Vector Modulation","Signal Synthesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/34731"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Alternating current motors are used throughout the fleet because of their rugged construction and nearly maintenance free operation. Since the U.S. Navy is exploring and acting on the possibilities of DC distribution systems, the need exists for simple, reliable three-phase voltage source inverter (VSI) powered induction machines. Until recently, VSIs utilized a pulse width modulation (PWM) scheme controlling the frequency and amplitude of each phase. A novel and simple hardware centered VSI controller was designed, simulated, built and tested featuring a type of space vector modulation (SVM). Design criteria evaluated such as VSI frequency response, switching losses, dead-time and SVM switching sequences were considered. Specifically, modulo-6 and 12 synthetic SVM units were evaluated for future Department of Defense use."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/syntheticspaceve1094534731"]},{"key":"dc:title","label":"Title","values":["Synthetic space vector modulation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Civilian, Department of the Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ashton, Robert W."],"dc:contributor.committeemember":["Parker, Andrew A."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Rogers, L Warren"],"dc:date":["Jun-13"],"dc:date.accessioned":["2013-08-01T16:51:53Z"],"dc:date.available":["2013-08-01T16:51:53Z"],"dc:date.issued":["2013-06"],"dc:description.abstract":["Alternating current motors are used throughout the fleet because of their rugged construction and nearly maintenance free operation. Since the U.S. Navy is exploring and acting on the possibilities of DC distribution systems, the need exists for simple, reliable three-phase voltage source inverter (VSI) powered induction machines. Until recently, VSIs utilized a pulse width modulation (PWM) scheme controlling the frequency and amplitude of each phase. A novel and simple hardware centered VSI controller was designed, simulated, built and tested featuring a type of space vector modulation (SVM). Design criteria evaluated such as VSI frequency response, switching losses, dead-time and SVM switching sequences were considered. Specifically, modulo-6 and 12 synthetic SVM units were evaluated for future Department of Defense use."],"dc:description.uri":["http://archive.org/details/syntheticspaceve1094534731"],"dc:identifier.uri":["https://hdl.handle.net/10945/34731"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Modulo-6 Counters","Self-Correcting Counters","Three-Phase Motor Controls","Multiplexed Center-Aligned Pulse Trains","Three-Phase Multiplexer","Voltage Source Inverter","Space Vector Modulation","Synthetic Space Vector Modulation","Signal Synthesis"],"dc:title":["Synthetic space vector modulation"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Civilian, Department of the Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science","Master of Science in Electrical Engineering"]},"updated_at":"2026-11-26T00:16:25Z"}