{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/34816"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/34816","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Experimental analysis of beam B-Dot sensors","abstract":"A new design for non-self integrating magnetic-loop sensors (B-dots) has been developed at Los Alamos National Laboratory. Experiments and tests were performed using the Relativistic Electron Beam Experiment (REX) machine to compare the B-dot sensors to optical beam diagnostics (streak camera). the B- dots were assessed to have the capability of measuring the REX electron beam's position to within 0.25mm with 2 percent error, and its transverse oscillatory movement to within 0.5mm amplitude with 7 percent error, over a 1 GHz bandwidth. Many calibration parameters and factors affecting sensor signals were examined during the experiment. The experimental calibration of the B-dots, and the resulting certified accuracy of their remote, non-intrusive measurements of relativistic electron beam parameters should have a wide range of application to many other electron beam machines.","abstract_html":"A new design for non-self integrating magnetic-loop sensors (B-dots) has been developed at Los Alamos National Laboratory. Experiments and tests were performed using the Relativistic Electron Beam Experiment (REX) machine to compare the B-dot sensors to optical beam diagnostics (streak camera). the B- dots were assessed to have the capability of measuring the REX electron beam&#x27;s position to within 0.25mm with 2 percent error, and its transverse oscillatory movement to within 0.5mm amplitude with 7 percent error, over a 1 GHz bandwidth. Many calibration parameters and factors affecting sensor signals were examined during the experiment. The experimental calibration of the B-dots, and the resulting certified accuracy of their remote, non-intrusive measurements of relativistic electron beam parameters should have a wide range of application to many other electron beam machines.","abstract_has_math":false,"creators":["Nye, Holly Lawrence"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics","school":null,"contributors":[],"advisors":["Neighbours, J.R."],"committee_chairs":[],"committee_members":["Maruyama, X.K."],"year":1990,"date_issued":"1990-06","date_published":"1990-06","updated_at":"2026-11-19T06:33:31Z","subjects":["Physics."],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/34816","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/34816","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F34816","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F34816","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Neighbours, J.R."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Maruyama, X.K."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Nye, Holly Lawrence"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1990-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-01T21:15:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-01T21:15:15Z"]},{"key":"dc:date.issued","label":"Date","values":["1990-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["B-dot sensors","non-self integrating inductive loop sensors","REX"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/34816"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A new design for non-self integrating magnetic-loop sensors (B-dots) has been developed at Los Alamos National Laboratory. Experiments and tests were performed using the Relativistic Electron Beam Experiment (REX) machine to compare the B-dot sensors to optical beam diagnostics (streak camera). the B- dots were assessed to have the capability of measuring the REX electron beam's position to within 0.25mm with 2 percent error, and its transverse oscillatory movement to within 0.5mm amplitude with 7 percent error, over a 1 GHz bandwidth. Many calibration parameters and factors affecting sensor signals were examined during the experiment. The experimental calibration of the B-dots, and the resulting certified accuracy of their remote, non-intrusive measurements of relativistic electron beam parameters should have a wide range of application to many other electron beam machines."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/experimentalnaly1094534816"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vi, 159 p. ill."]},{"key":"dc:title","label":"Title","values":["Experimental analysis of beam B-Dot sensors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Neighbours, J.R."],"dc:contributor.committeemember":["Maruyama, X.K."],"dc:contributor.department":["Physics"],"dc:creator":["Nye, Holly Lawrence"],"dc:date":["1990-06"],"dc:date.accessioned":["2013-08-01T21:15:15Z"],"dc:date.available":["2013-08-01T21:15:15Z"],"dc:date.issued":["1990-06"],"dc:description.abstract":["A new design for non-self integrating magnetic-loop sensors (B-dots) has been developed at Los Alamos National Laboratory. Experiments and tests were performed using the Relativistic Electron Beam Experiment (REX) machine to compare the B-dot sensors to optical beam diagnostics (streak camera). the B- dots were assessed to have the capability of measuring the REX electron beam's position to within 0.25mm with 2 percent error, and its transverse oscillatory movement to within 0.5mm amplitude with 7 percent error, over a 1 GHz bandwidth. Many calibration parameters and factors affecting sensor signals were examined during the experiment. The experimental calibration of the B-dots, and the resulting certified accuracy of their remote, non-intrusive measurements of relativistic electron beam parameters should have a wide range of application to many other electron beam machines."],"dc:description.uri":["http://archive.org/details/experimentalnaly1094534816"],"dc:format.extent":["vi, 159 p. ill."],"dc:identifier.uri":["https://hdl.handle.net/10945/34816"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["B-dot sensors","non-self integrating inductive loop sensors","REX"],"dc:subject.lcsh":["Physics."],"dc:title":["Experimental analysis of beam B-Dot sensors"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:33:31Z"}