{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/34872"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/34872","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Heat transfer, adiabatic effectiveness and injectant distributions downstream of single and double rows of film-cooling holes with compound angles","abstract":"Experimental results are presented which describe the development and structure of turbulent boundary layer flow downstream of single and double rows of film-cooling holes with compound angles. The film-cooling holes are inclined at an angle of 30 degrees when projected into the spanwisenormal (Y-Z) planes and at an angle of 35 degrees when projected into the streamwisenormal (X-Y) planes with respect to the test surface. Three configurations are used: (1) one row of film-cooling holes with a blowing ratio of m=0.5, (2) one row of film- cooling holes with a blowing ratio of m=1.0, and (3) two staggered row of film- cooling holes with a blowing ratio of m=0.5. Results indicate that the highest eta values are obtained when two rows of compound angle injection cooling holes are employed with a blowing ratio of m=0.5, and that the lowest eta values results when one row of compound angle injection cooling holes is employed with a blowing ratio of m=1.0. Near film cooling holes and for xd as high as 87, streamwise mean velocity and total pressure distributions show spanwise periodicity near the wall as a result of the discrete nature of film injection. At xd=10.2, injectant distributions are non-circular in spanwise normal planes. These distributions spread in lateral and normal directions as the boundary layer convects downstream.","abstract_html":"Experimental results are presented which describe the development and structure of turbulent boundary layer flow downstream of single and double rows of film-cooling holes with compound angles. The film-cooling holes are inclined at an angle of 30 degrees when projected into the spanwisenormal (Y-Z) planes and at an angle of 35 degrees when projected into the streamwisenormal (X-Y) planes with respect to the test surface. Three configurations are used: (1) one row of film-cooling holes with a blowing ratio of m=0.5, (2) one row of film- cooling holes with a blowing ratio of m=1.0, and (3) two staggered row of film- cooling holes with a blowing ratio of m=0.5. Results indicate that the highest eta values are obtained when two rows of compound angle injection cooling holes are employed with a blowing ratio of m=0.5, and that the lowest eta values results when one row of compound angle injection cooling holes is employed with a blowing ratio of m=1.0. Near film cooling holes and for xd as high as 87, streamwise mean velocity and total pressure distributions show spanwise periodicity near the wall as a result of the discrete nature of film injection. At xd=10.2, injectant distributions are non-circular in spanwise normal planes. These distributions spread in lateral and normal directions as the boundary layer convects downstream.","abstract_has_math":false,"creators":["Bishop, David Turner"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Ligrani, Phillip M","Subramanian, Chelakara S."],"committee_chairs":[],"committee_members":["Ligrani, Phillip M","Subramanian, Chelakara S."],"year":1990,"date_issued":"1990-09","date_published":"1990-09","updated_at":"2026-11-19T06:33:31Z","subjects":["Heat","Transmission","Speed."],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/34872","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/34872","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F34872","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ligrani, Phillip M","Subramanian, Chelakara S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Ligrani, Phillip M","Subramanian, Chelakara S."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bishop, David Turner"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1990-09"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-01T21:15:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-01T21:15:36Z"]},{"key":"dc:date.issued","label":"Date","values":["1990-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Compound angel injection","embedded vortex","film-cooling","turbulent boundary layer"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Heat","Transmission","Speed."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/34872"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Experimental results are presented which describe the development and structure of turbulent boundary layer flow downstream of single and double rows of film-cooling holes with compound angles. The film-cooling holes are inclined at an angle of 30 degrees when projected into the spanwisenormal (Y-Z) planes and at an angle of 35 degrees when projected into the streamwisenormal (X-Y) planes with respect to the test surface. Three configurations are used: (1) one row of film-cooling holes with a blowing ratio of m=0.5, (2) one row of film- cooling holes with a blowing ratio of m=1.0, and (3) two staggered row of film- cooling holes with a blowing ratio of m=0.5. Results indicate that the highest eta values are obtained when two rows of compound angle injection cooling holes are employed with a blowing ratio of m=0.5, and that the lowest eta values results when one row of compound angle injection cooling holes is employed with a blowing ratio of m=1.0. Near film cooling holes and for xd as high as 87, streamwise mean velocity and total pressure distributions show spanwise periodicity near the wall as a result of the discrete nature of film injection. At xd=10.2, injectant distributions are non-circular in spanwise normal planes. These distributions spread in lateral and normal directions as the boundary layer convects downstream."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/heattransferdiab1094534872"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiii, 136 p. ill."]},{"key":"dc:title","label":"Title","values":["Heat transfer, adiabatic effectiveness and injectant distributions downstream of single and double rows of film-cooling holes with compound angles"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ligrani, Phillip M","Subramanian, Chelakara S."],"dc:contributor.committeemember":["Ligrani, Phillip M","Subramanian, Chelakara S."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Bishop, David Turner"],"dc:date":["1990-09"],"dc:date.accessioned":["2013-08-01T21:15:36Z"],"dc:date.available":["2013-08-01T21:15:36Z"],"dc:date.issued":["1990-09"],"dc:description.abstract":["Experimental results are presented which describe the development and structure of turbulent boundary layer flow downstream of single and double rows of film-cooling holes with compound angles. The film-cooling holes are inclined at an angle of 30 degrees when projected into the spanwisenormal (Y-Z) planes and at an angle of 35 degrees when projected into the streamwisenormal (X-Y) planes with respect to the test surface. Three configurations are used: (1) one row of film-cooling holes with a blowing ratio of m=0.5, (2) one row of film- cooling holes with a blowing ratio of m=1.0, and (3) two staggered row of film- cooling holes with a blowing ratio of m=0.5. Results indicate that the highest eta values are obtained when two rows of compound angle injection cooling holes are employed with a blowing ratio of m=0.5, and that the lowest eta values results when one row of compound angle injection cooling holes is employed with a blowing ratio of m=1.0. Near film cooling holes and for xd as high as 87, streamwise mean velocity and total pressure distributions show spanwise periodicity near the wall as a result of the discrete nature of film injection. At xd=10.2, injectant distributions are non-circular in spanwise normal planes. These distributions spread in lateral and normal directions as the boundary layer convects downstream."],"dc:description.uri":["http://archive.org/details/heattransferdiab1094534872"],"dc:format.extent":["xiii, 136 p. ill."],"dc:identifier.uri":["https://hdl.handle.net/10945/34872"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Compound angel injection","embedded vortex","film-cooling","turbulent boundary layer"],"dc:subject.lcsh":["Heat","Transmission","Speed."],"dc:title":["Heat transfer, adiabatic effectiveness and injectant distributions downstream of single and double rows of film-cooling holes with compound angles"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:33:31Z"}