{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/34998"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/34998","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Effects of power pulsations on natural convection from discrete heat sources.","abstract":"The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range.","abstract_html":"The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range.","abstract_has_math":false,"creators":["Akdeniz, Erhan Murat"],"institution":"Monterey, California: U.S. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Joshi, Yogendra"],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991-03","date_published":"1991-03","updated_at":"2026-11-21T22:38:54Z","subjects":[],"languages":[],"rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/34998","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/34998","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F34998","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F34998","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joshi, Yogendra"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Akdeniz, Erhan Murat"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1991-03"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-08-08T17:57:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-08-08T17:57:14Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: U.S. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/34998"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/effectsofpowerpu1094534998"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["95 p.;28 cm."]},{"key":"dc:title","label":"Title","values":["Effects of power pulsations on natural convection from discrete heat sources."]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant (j.g.), Turkish Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joshi, Yogendra"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Akdeniz, Erhan Murat"],"dc:date":["1991-03"],"dc:date.accessioned":["2013-08-08T17:57:14Z"],"dc:date.available":["2013-08-08T17:57:14Z"],"dc:date.issued":["1991-03"],"dc:description.abstract":["The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range."],"dc:description.uri":["http://archive.org/details/effectsofpowerpu1094534998"],"dc:format.extent":["95 p.;28 cm."],"dc:identifier.uri":["https://hdl.handle.net/10945/34998"],"dc:publisher":["Monterey, California: U.S. Naval Postgraduate School"],"dc:rights":["Copyright is reserved by the copyright owner.","Approved for public release; distribution is unlimited."],"dc:title":["Effects of power pulsations on natural convection from discrete heat sources."],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant (j.g.), Turkish Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:38:54Z"}