{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/3686"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/3686","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Analyzing the effects of component reliability on naval integrated power system quality of service","abstract":"The Integrated Power System (IPS) is a key enabling technology for future naval vessels and their advanced weapon systems. While conventional warship designs utilize separate power systems for propulsion and shipboard electrical service, the IPS combines these functions. This allows greater optimization of engineering plant design and operations and leads to significant potential lifecycle cost savings through reduced fuel consumption and maintenance. Traditionally the focus of power system design has been survivability, with the assumption that service continuity was inherently provided. A new probabilistic metric, Quality of Service (QOS), now allows the power continuity and quality delivered to loads to be addressed explicitly during the design of IPS vessels. This metric is based both on the reliability of the power system components and the system architecture employed.","abstract_html":"The Integrated Power System (IPS) is a key enabling technology for future naval vessels and their advanced weapon systems. While conventional warship designs utilize separate power systems for propulsion and shipboard electrical service, the IPS combines these functions. This allows greater optimization of engineering plant design and operations and leads to significant potential lifecycle cost savings through reduced fuel consumption and maintenance. Traditionally the focus of power system design has been survivability, with the assumption that service continuity was inherently provided. A new probabilistic metric, Quality of Service (QOS), now allows the power continuity and quality delivered to loads to be addressed explicitly during the design of IPS vessels. This metric is based both on the reliability of the power system components and the system architecture employed.","abstract_has_math":false,"creators":["Hawbaker, Benjamin F."],"institution":"Massachusetts Institute of Technology","degree_name":"Naval Engineer","degree_level":"Masters","degree_discipline":"Naval Engineer","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-06","date_published":"2008-06","updated_at":"2026-11-19T06:33:48Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["463690"],"render_values":[{"text":"463690","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/3686","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/3686","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F3686","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["CIVINS (Civilian Institutions)"]},{"key":"dc:creator","label":"Author","values":["Hawbaker, Benjamin F."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:39:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:39:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-06"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["CIVINS (Civilian Institutions) Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Naval Engineer","Engineering and Management"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Naval Engineer","Master of Science in Engineering and Management"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Massachusetts Institute of Technology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["463690"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/3686"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Integrated Power System (IPS) is a key enabling technology for future naval vessels and their advanced weapon systems. While conventional warship designs utilize separate power systems for propulsion and shipboard electrical service, the IPS combines these functions. This allows greater optimization of engineering plant design and operations and leads to significant potential lifecycle cost savings through reduced fuel consumption and maintenance. Traditionally the focus of power system design has been survivability, with the assumption that service continuity was inherently provided. A new probabilistic metric, Quality of Service (QOS), now allows the power continuity and quality delivered to loads to be addressed explicitly during the design of IPS vessels. This metric is based both on the reliability of the power system components and the system architecture employed."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["N62271-97-G-0026."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/analyzingeffects109453686"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["92 p."]},{"key":"dc:title","label":"Title","values":["Analyzing the effects of component reliability on naval integrated power system quality of service"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.other":["CIVINS (Civilian Institutions)"],"dc:creator":["Hawbaker, Benjamin F."],"dc:date.accessioned":["2012-03-14T17:39:04Z"],"dc:date.available":["2012-03-14T17:39:04Z"],"dc:date.issued":["2008-06"],"dc:description.abstract":["The Integrated Power System (IPS) is a key enabling technology for future naval vessels and their advanced weapon systems. While conventional warship designs utilize separate power systems for propulsion and shipboard electrical service, the IPS combines these functions. This allows greater optimization of engineering plant design and operations and leads to significant potential lifecycle cost savings through reduced fuel consumption and maintenance. Traditionally the focus of power system design has been survivability, with the assumption that service continuity was inherently provided. A new probabilistic metric, Quality of Service (QOS), now allows the power continuity and quality delivered to loads to be addressed explicitly during the design of IPS vessels. This metric is based both on the reliability of the power system components and the system architecture employed."],"dc:description.sponsorship":["N62271-97-G-0026."],"dc:description.uri":["http://archive.org/details/analyzingeffects109453686"],"dc:format.extent":["92 p."],"dc:identifier.oclc":["463690"],"dc:identifier.uri":["https://hdl.handle.net/10945/3686"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:relation.ispartofseries":["CIVINS (Civilian Institutions) Theses and Dissertations"],"dc:relation.orgunit":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"],"dc:relation.seriesentity":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:title":["Analyzing the effects of component reliability on naval integrated power system quality of service"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Naval Engineer","Engineering and Management"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Naval Engineer","Master of Science in Engineering and Management"],"thesis:institution_name":["Massachusetts Institute of Technology"]},"updated_at":"2026-11-19T06:33:48Z"}