{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/37693"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/37693","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Reducing stator current harmonics for a doubly-fed induction generator connected to a distorted grid","abstract":"The Department of Defense (DoD) is increasing its demand for reliable renewable energy sources. The doubly-fed induction generator (DFIG) is widely used to extract electrical energy from wind and is a useful means for the DoD to achieve its renewable energy goals. The DFIG is susceptible to electric grid voltage harmonics, which is a potential obstacle for implementing stable wind-energy systems. Two existing rotor voltage controllers are modeled in this thesis for eventual implementation in a laboratory DFIG wind energy system. The first controller uses multiple proportional-integral (PI) controllers to filter out the fifth and seventh stator current harmonics. Each PI controller operates in a reference frame that rotates in synchronicity with the harmonic that is being filtered. The second controller operates in the synchronous reference frame and simultaneously filters both the fifth and seventh stator current harmonics using a double integrator called a proportional-resonant controller (PR). The PI controller is shown to be more effective at eliminating the stator current than the PR controller but has a slower reaction time. The PR controller requires fewer computations but has more stability concerns. Both controllers reduce torque oscillations resulting from the grid distortion by approximately the same amount.","abstract_html":"The Department of Defense (DoD) is increasing its demand for reliable renewable energy sources. The doubly-fed induction generator (DFIG) is widely used to extract electrical energy from wind and is a useful means for the DoD to achieve its renewable energy goals. The DFIG is susceptible to electric grid voltage harmonics, which is a potential obstacle for implementing stable wind-energy systems. Two existing rotor voltage controllers are modeled in this thesis for eventual implementation in a laboratory DFIG wind energy system. The first controller uses multiple proportional-integral (PI) controllers to filter out the fifth and seventh stator current harmonics. Each PI controller operates in a reference frame that rotates in synchronicity with the harmonic that is being filtered. The second controller operates in the synchronous reference frame and simultaneously filters both the fifth and seventh stator current harmonics using a double integrator called a proportional-resonant controller (PR). The PI controller is shown to be more effective at eliminating the stator current than the PR controller but has a slower reaction time. The PR controller requires fewer computations but has more stability concerns. Both controllers reduce torque oscillations resulting from the grid distortion by approximately the same amount.","abstract_has_math":false,"creators":["Pierce, Seth J."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Julian, Alexander L."],"committee_chairs":[],"committee_members":["Cristi, Roberto"],"year":2013,"date_issued":"2013-09","date_published":"2013-09","updated_at":"2026-11-19T06:34:01Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/37693","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/37693","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F37693","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Julian, Alexander L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Cristi, Roberto"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Pierce, Seth J."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Sep-13"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-11-20T23:36:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-11-20T23:36:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["88110183-ea50-46f5-b469-809c1418a16d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["doubly-fed induction generator","harmonic distortion","resonant controller"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/37693"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The Department of Defense (DoD) is increasing its demand for reliable renewable energy sources. The doubly-fed induction generator (DFIG) is widely used to extract electrical energy from wind and is a useful means for the DoD to achieve its renewable energy goals. The DFIG is susceptible to electric grid voltage harmonics, which is a potential obstacle for implementing stable wind-energy systems. Two existing rotor voltage controllers are modeled in this thesis for eventual implementation in a laboratory DFIG wind energy system. The first controller uses multiple proportional-integral (PI) controllers to filter out the fifth and seventh stator current harmonics. Each PI controller operates in a reference frame that rotates in synchronicity with the harmonic that is being filtered. The second controller operates in the synchronous reference frame and simultaneously filters both the fifth and seventh stator current harmonics using a double integrator called a proportional-resonant controller (PR). The PI controller is shown to be more effective at eliminating the stator current than the PR controller but has a slower reaction time. The PR controller requires fewer computations but has more stability concerns. Both controllers reduce torque oscillations resulting from the grid distortion by approximately the same amount."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/reducingstatorcu1094537693"]},{"key":"dc:title","label":"Title","values":["Reducing stator current harmonics for a doubly-fed induction generator connected to a distorted grid"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Julian, Alexander L."],"dc:contributor.committeemember":["Cristi, Roberto"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Pierce, Seth J."],"dc:date":["Sep-13"],"dc:date.accessioned":["2013-11-20T23:36:23Z"],"dc:date.available":["2013-11-20T23:36:23Z"],"dc:date.issued":["2013-09"],"dc:description.abstract":["The Department of Defense (DoD) is increasing its demand for reliable renewable energy sources. The doubly-fed induction generator (DFIG) is widely used to extract electrical energy from wind and is a useful means for the DoD to achieve its renewable energy goals. The DFIG is susceptible to electric grid voltage harmonics, which is a potential obstacle for implementing stable wind-energy systems. Two existing rotor voltage controllers are modeled in this thesis for eventual implementation in a laboratory DFIG wind energy system. The first controller uses multiple proportional-integral (PI) controllers to filter out the fifth and seventh stator current harmonics. Each PI controller operates in a reference frame that rotates in synchronicity with the harmonic that is being filtered. The second controller operates in the synchronous reference frame and simultaneously filters both the fifth and seventh stator current harmonics using a double integrator called a proportional-resonant controller (PR). The PI controller is shown to be more effective at eliminating the stator current than the PR controller but has a slower reaction time. The PR controller requires fewer computations but has more stability concerns. Both controllers reduce torque oscillations resulting from the grid distortion by approximately the same amount."],"dc:description.uri":["http://archive.org/details/reducingstatorcu1094537693"],"dc:identifier.uri":["https://hdl.handle.net/10945/37693"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["88110183-ea50-46f5-b469-809c1418a16d"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["doubly-fed induction generator","harmonic distortion","resonant controller"],"dc:title":["Reducing stator current harmonics for a doubly-fed induction generator connected to a distorted grid"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:34:01Z"}