{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/37776"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/37776","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Modeling Cryptosporidium spp. Oocyst inactivation in bubble-diffuser ozone contactors","abstract":"The CT concept (product of disinfectant concentration and characteristic contact time) is currently used to demonstrate compliance with disinfection requirements for Giarda lamblia (G. lamblia) and viruses under the Surface Water Treatment Rule (SWTR). Minimum CT requirements include large safety factors to account for possible deviations from actual disinfection efficiencies achieved in full-scale contactors. The application of this conservative regulatory approach for Cryptosporidium parvum (C. parvum) might result in unrealistic disinfection requirements under the Enhanced SWTR due to the much stronger resistance of this protozoan parasite to inactivation by all chemical disinfectants used in drinking water applications. There is a need for the development of approaches that could provide a more accurate assessmant of actual inactivation efficiency achieved in disinfection contactors. The main objective of this study is to develop and apply a mathematical model predicting the inactivation of Cryptosporidium app. (C. parvum and C. muris) oocysts in ozone bubble-diffusers contactors. The model is calibrated with semi-batch kinetic data, verified with pilot-scale inactivation experiments, and used for predicting and optimizing full-scale disinfection efficiency.","abstract_html":"The CT concept (product of disinfectant concentration and characteristic contact time) is currently used to demonstrate compliance with disinfection requirements for Giarda lamblia (G. lamblia) and viruses under the Surface Water Treatment Rule (SWTR). Minimum CT requirements include large safety factors to account for possible deviations from actual disinfection efficiencies achieved in full-scale contactors. The application of this conservative regulatory approach for Cryptosporidium parvum (C. parvum) might result in unrealistic disinfection requirements under the Enhanced SWTR due to the much stronger resistance of this protozoan parasite to inactivation by all chemical disinfectants used in drinking water applications. There is a need for the development of approaches that could provide a more accurate assessmant of actual inactivation efficiency achieved in disinfection contactors. The main objective of this study is to develop and apply a mathematical model predicting the inactivation of Cryptosporidium app. (C. parvum and C. muris) oocysts in ozone bubble-diffusers contactors. The model is calibrated with semi-batch kinetic data, verified with pilot-scale inactivation experiments, and used for predicting and optimizing full-scale disinfection efficiency.","abstract_has_math":false,"creators":["Tomiak, Robert B.","Rennecker, Jason L.","Marinas, Benito J.","Miltner, Richard J.","Owens, James H."],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Special Project","degree_level":null,"degree_discipline":"Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1998,"date_issued":"1998-07","date_published":"1998-07","updated_at":"2026-11-19T06:34:01Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/37776","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/37776","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F37776","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F37776","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["CIVINS (Civilian Institutions)"]},{"key":"dc:creator","label":"Author","values":["Tomiak, Robert B.","Rennecker, Jason L.","Marinas, Benito J.","Miltner, Richard J.","Owens, James H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-11-21T22:48:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-11-21T22:48:54Z"]},{"key":"dc:date.issued","label":"Date","values":["1998-07"]},{"key":"dc:publisher","label":"Institution","values":["University of Illinois at Urbana-Champaign"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["CIVINS (Civilian Institutions) Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Special Project"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/37776"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The CT concept (product of disinfectant concentration and characteristic contact time) is currently used to demonstrate compliance with disinfection requirements for Giarda lamblia (G. lamblia) and viruses under the Surface Water Treatment Rule (SWTR). Minimum CT requirements include large safety factors to account for possible deviations from actual disinfection efficiencies achieved in full-scale contactors. The application of this conservative regulatory approach for Cryptosporidium parvum (C. parvum) might result in unrealistic disinfection requirements under the Enhanced SWTR due to the much stronger resistance of this protozoan parasite to inactivation by all chemical disinfectants used in drinking water applications. There is a need for the development of approaches that could provide a more accurate assessmant of actual inactivation efficiency achieved in disinfection contactors. The main objective of this study is to develop and apply a mathematical model predicting the inactivation of Cryptosporidium app. (C. parvum and C. muris) oocysts in ozone bubble-diffusers contactors. The model is calibrated with semi-batch kinetic data, verified with pilot-scale inactivation experiments, and used for predicting and optimizing full-scale disinfection efficiency."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/modelingcryptosp1094537776"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["75 p."]},{"key":"dc:title","label":"Title","values":["Modeling Cryptosporidium spp. Oocyst inactivation in bubble-diffuser ozone contactors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.other":["CIVINS (Civilian Institutions)"],"dc:creator":["Tomiak, Robert B.","Rennecker, Jason L.","Marinas, Benito J.","Miltner, Richard J.","Owens, James H."],"dc:date.accessioned":["2013-11-21T22:48:54Z"],"dc:date.available":["2013-11-21T22:48:54Z"],"dc:date.issued":["1998-07"],"dc:description.abstract":["The CT concept (product of disinfectant concentration and characteristic contact time) is currently used to demonstrate compliance with disinfection requirements for Giarda lamblia (G. lamblia) and viruses under the Surface Water Treatment Rule (SWTR). Minimum CT requirements include large safety factors to account for possible deviations from actual disinfection efficiencies achieved in full-scale contactors. The application of this conservative regulatory approach for Cryptosporidium parvum (C. parvum) might result in unrealistic disinfection requirements under the Enhanced SWTR due to the much stronger resistance of this protozoan parasite to inactivation by all chemical disinfectants used in drinking water applications. There is a need for the development of approaches that could provide a more accurate assessmant of actual inactivation efficiency achieved in disinfection contactors. The main objective of this study is to develop and apply a mathematical model predicting the inactivation of Cryptosporidium app. (C. parvum and C. muris) oocysts in ozone bubble-diffusers contactors. The model is calibrated with semi-batch kinetic data, verified with pilot-scale inactivation experiments, and used for predicting and optimizing full-scale disinfection efficiency."],"dc:description.uri":["http://archive.org/details/modelingcryptosp1094537776"],"dc:format.extent":["75 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/37776"],"dc:publisher":["University of Illinois at Urbana-Champaign"],"dc:relation.ispartofseries":["CIVINS (Civilian Institutions) Theses and Dissertations"],"dc:relation.orgunit":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"],"dc:relation.seriesentity":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:title":["Modeling Cryptosporidium spp. Oocyst inactivation in bubble-diffuser ozone contactors"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Environmental Engineering"],"thesis:degree_name":["Special Project"],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-11-19T06:34:01Z"}