{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/39416"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/39416","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Use of pin-jointed members in rapidly constructed temporary bridges","abstract":"This project examines the feasibility of the creating a re-usable modular bridge \"kit\" that can be adaptable to meet the dimensional and loading needs of a given situation. The resulting body of work considers such a kit using a pin-jointed Warren truss capable of spanning distances of at least 100 feet and greater and capable of supporting common military transport vehicles of 50,000lbs and more. An analysis of each individual truss member is performed using a FORTRAN F90 program governed by LRFD (AISC) and AASHTO specifications. The computer program makes use of the Compatability Matrix Method in the identification of the maximum force generated in each member as the result of a rolling load. The program allows the user to consider any span and load requirement and to assign individual member cross-sectional areas in order to determine the optimum design of members based upon total truss weight and maximum deflection. It is shown that a modular bridge \"kit\" is possible using a two member size configuration for a through truss, and a single member size using a deck truss configuration. A detailed example is provided, illustrating member-sizing requirements to span a distance of l 12ft and support a fully loaded 5-ton transport vehicle.","abstract_html":"This project examines the feasibility of the creating a re-usable modular bridge &quot;kit&quot; that can be adaptable to meet the dimensional and loading needs of a given situation. The resulting body of work considers such a kit using a pin-jointed Warren truss capable of spanning distances of at least 100 feet and greater and capable of supporting common military transport vehicles of 50,000lbs and more. An analysis of each individual truss member is performed using a FORTRAN F90 program governed by LRFD (AISC) and AASHTO specifications. The computer program makes use of the Compatability Matrix Method in the identification of the maximum force generated in each member as the result of a rolling load. The program allows the user to consider any span and load requirement and to assign individual member cross-sectional areas in order to determine the optimum design of members based upon total truss weight and maximum deflection. It is shown that a modular bridge &quot;kit&quot; is possible using a two member size configuration for a through truss, and a single member size using a deck truss configuration. A detailed example is provided, illustrating member-sizing requirements to span a distance of l 12ft and support a fully loaded 5-ton transport vehicle.","abstract_has_math":false,"creators":["Hornyak, Thomas E."],"institution":"Old Dominion University","degree_name":"Master of Engineering in Civil Engineering","degree_level":"Masters","degree_discipline":"Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999-08","date_published":"1999-08","updated_at":"2026-11-19T06:34:19Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640936975"],"render_values":[{"text":"ocn640936975","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/39416","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/39416","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F39416","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["CIVINS (Civilian Institutions)"]},{"key":"dc:creator","label":"Author","values":["Hornyak, Thomas E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-12T18:26:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-12T18:26:11Z"]},{"key":"dc:date.issued","label":"Date","values":["1999-08"]},{"key":"dc:publisher","label":"Institution","values":["Old Dominion University"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["CIVINS (Civilian Institutions) Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering","Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering in Civil Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Old Dominion University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640936975"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/39416"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Includes supplementary material. The following documents are included: Hornyak_FORTAN_Programs.zip (includes the files \"stiffness_subs.F90\", \"Inverter.f90\", \"multiload_MAIN.f90\", \"Multiload_subs.F90\", \"singleload_MAIN.f90\", \"Sinlgeload_subs.F90\", \"Solver.f90\", \"stiffness_MAIN.F90\", \"RESULTS.TXT\") and Hornyak_EXCEL.zip (includes the files \"EXCEL Loading Tables.xls\", \"Loading Cycles.xls\", \"MATRICES.xls\", \"Report Tables.xls)"]},{"key":"dc:description.abstract","label":"Abstract","values":["This project examines the feasibility of the creating a re-usable modular bridge \"kit\" that can be adaptable to meet the dimensional and loading needs of a given situation. The resulting body of work considers such a kit using a pin-jointed Warren truss capable of spanning distances of at least 100 feet and greater and capable of supporting common military transport vehicles of 50,000lbs and more. An analysis of each individual truss member is performed using a FORTRAN F90 program governed by LRFD (AISC) and AASHTO specifications. The computer program makes use of the Compatability Matrix Method in the identification of the maximum force generated in each member as the result of a rolling load. The program allows the user to consider any span and load requirement and to assign individual member cross-sectional areas in order to determine the optimum design of members based upon total truss weight and maximum deflection. It is shown that a modular bridge \"kit\" is possible using a two member size configuration for a through truss, and a single member size using a deck truss configuration. A detailed example is provided, illustrating member-sizing requirements to span a distance of l 12ft and support a fully loaded 5-ton transport vehicle."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/useofpinjointedm1094539416"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["67 p."]},{"key":"dc:title","label":"Title","values":["Use of pin-jointed members in rapidly constructed temporary bridges"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]}]}],"canonical_facts":{"dc:contributor.other":["CIVINS (Civilian Institutions)"],"dc:creator":["Hornyak, Thomas E."],"dc:date.accessioned":["2014-03-12T18:26:11Z"],"dc:date.available":["2014-03-12T18:26:11Z"],"dc:date.issued":["1999-08"],"dc:description":["Includes supplementary material. The following documents are included: Hornyak_FORTAN_Programs.zip (includes the files \"stiffness_subs.F90\", \"Inverter.f90\", \"multiload_MAIN.f90\", \"Multiload_subs.F90\", \"singleload_MAIN.f90\", \"Sinlgeload_subs.F90\", \"Solver.f90\", \"stiffness_MAIN.F90\", \"RESULTS.TXT\") and Hornyak_EXCEL.zip (includes the files \"EXCEL Loading Tables.xls\", \"Loading Cycles.xls\", \"MATRICES.xls\", \"Report Tables.xls)"],"dc:description.abstract":["This project examines the feasibility of the creating a re-usable modular bridge \"kit\" that can be adaptable to meet the dimensional and loading needs of a given situation. The resulting body of work considers such a kit using a pin-jointed Warren truss capable of spanning distances of at least 100 feet and greater and capable of supporting common military transport vehicles of 50,000lbs and more. An analysis of each individual truss member is performed using a FORTRAN F90 program governed by LRFD (AISC) and AASHTO specifications. The computer program makes use of the Compatability Matrix Method in the identification of the maximum force generated in each member as the result of a rolling load. The program allows the user to consider any span and load requirement and to assign individual member cross-sectional areas in order to determine the optimum design of members based upon total truss weight and maximum deflection. It is shown that a modular bridge \"kit\" is possible using a two member size configuration for a through truss, and a single member size using a deck truss configuration. A detailed example is provided, illustrating member-sizing requirements to span a distance of l 12ft and support a fully loaded 5-ton transport vehicle."],"dc:description.uri":["http://archive.org/details/useofpinjointedm1094539416"],"dc:format.extent":["67 p."],"dc:identifier.oclc":["ocn640936975"],"dc:identifier.uri":["https://hdl.handle.net/10945/39416"],"dc:publisher":["Old Dominion University"],"dc:relation.ispartofseries":["CIVINS (Civilian Institutions) Theses and Dissertations"],"dc:relation.orgunit":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"],"dc:relation.seriesentity":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States."],"dc:title":["Use of pin-jointed members in rapidly constructed temporary bridges"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"thesis:degree_discipline":["Engineering","Civil Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Engineering in Civil Engineering"],"thesis:institution_name":["Old Dominion University"]},"updated_at":"2026-11-19T06:34:19Z"}