{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/41429"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/41429","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Evaluation of data processing techniques for unobtrusive gait authentication","abstract":"The growth in smartphone usage has led to increased storage of sensitive data on these easily lost or stolen devices. In order to mitigate the effects of users who ignore, disable, or circumvent authentication measures like passwords, we evaluate a method employing gait as a source of identifying information. This research is based on previously reported methods with a goal of evaluating gait signal processing and classification techniques. This thesis evaluates the performance of four signal normalization techniques (raw signal, zero-scaled, gravity-rotated, and gravity rotated with zero-scaling). Additionally, we evaluate the effect of carrying position on classification. Data was captured from 23 subjects carrying the device in the front pocket, back pocket, and on the hip. Unlike previous research, we analyzed classifier performance on data collected from multiple positions and tested on each individual location, which would be necessary in a robust, deployable system. Our results indicate that restricting device position can achieve the best overall performance using zero-scaling with 6.13% total error rate (TER) on the XY-axis but with a high variance across different axes. Using data from all positions with gravity rotation can achieve 12.6% TER with a low statistical variance.","abstract_html":"The growth in smartphone usage has led to increased storage of sensitive data on these easily lost or stolen devices. In order to mitigate the effects of users who ignore, disable, or circumvent authentication measures like passwords, we evaluate a method employing gait as a source of identifying information. This research is based on previously reported methods with a goal of evaluating gait signal processing and classification techniques. This thesis evaluates the performance of four signal normalization techniques (raw signal, zero-scaled, gravity-rotated, and gravity rotated with zero-scaling). Additionally, we evaluate the effect of carrying position on classification. Data was captured from 23 subjects carrying the device in the front pocket, back pocket, and on the hip. Unlike previous research, we analyzed classifier performance on data collected from multiple positions and tested on each individual location, which would be necessary in a robust, deployable system. Our results indicate that restricting device position can achieve the best overall performance using zero-scaling with 6.13% total error rate (TER) on the XY-axis but with a high variance across different axes. Using data from all positions with gravity rotation can achieve 12.6% TER with a low statistical variance.","abstract_has_math":false,"creators":["Parker, William A."],"institution":"Monterey, California: Naval Postgraduate School","degree_name":"Master Of Science In Computer Science","degree_level":"Masters","degree_discipline":"Computer Science","degree_department":"Computer Science","school":null,"contributors":[],"advisors":["Martell, Craig","Gondree, Mark"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-03","date_published":"2014-03","updated_at":"2026-11-19T06:34:46Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/41429","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/41429","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F41429","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F41429","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Martell, Craig","Gondree, Mark"]},{"key":"dc:contributor.department","label":"Department","values":["Computer Science"]},{"key":"dc:creator","label":"Author","values":["Parker, William A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Mar-14"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-05-23T15:19:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-05-23T15:19:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Computer Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master Of Science In Computer Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Smartphone authentication","accelerometer gait recognition","signal processing","quaternion rotation","gravity calibration","machine learning","support vector machine","k-nearest neighbors"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/41429"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The growth in smartphone usage has led to increased storage of sensitive data on these easily lost or stolen devices. In order to mitigate the effects of users who ignore, disable, or circumvent authentication measures like passwords, we evaluate a method employing gait as a source of identifying information. This research is based on previously reported methods with a goal of evaluating gait signal processing and classification techniques. This thesis evaluates the performance of four signal normalization techniques (raw signal, zero-scaled, gravity-rotated, and gravity rotated with zero-scaling). Additionally, we evaluate the effect of carrying position on classification. Data was captured from 23 subjects carrying the device in the front pocket, back pocket, and on the hip. Unlike previous research, we analyzed classifier performance on data collected from multiple positions and tested on each individual location, which would be necessary in a robust, deployable system. Our results indicate that restricting device position can achieve the best overall performance using zero-scaling with 6.13% total error rate (TER) on the XY-axis but with a high variance across different axes. Using data from all positions with gravity rotation can achieve 12.6% TER with a low statistical variance."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/evaluationofdatp1094541429"]},{"key":"dc:title","label":"Title","values":["Evaluation of data processing techniques for unobtrusive gait authentication"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Martell, Craig","Gondree, Mark"],"dc:contributor.department":["Computer Science"],"dc:creator":["Parker, William A."],"dc:date":["Mar-14"],"dc:date.accessioned":["2014-05-23T15:19:38Z"],"dc:date.available":["2014-05-23T15:19:38Z"],"dc:date.issued":["2014-03"],"dc:description.abstract":["The growth in smartphone usage has led to increased storage of sensitive data on these easily lost or stolen devices. In order to mitigate the effects of users who ignore, disable, or circumvent authentication measures like passwords, we evaluate a method employing gait as a source of identifying information. This research is based on previously reported methods with a goal of evaluating gait signal processing and classification techniques. This thesis evaluates the performance of four signal normalization techniques (raw signal, zero-scaled, gravity-rotated, and gravity rotated with zero-scaling). Additionally, we evaluate the effect of carrying position on classification. Data was captured from 23 subjects carrying the device in the front pocket, back pocket, and on the hip. Unlike previous research, we analyzed classifier performance on data collected from multiple positions and tested on each individual location, which would be necessary in a robust, deployable system. Our results indicate that restricting device position can achieve the best overall performance using zero-scaling with 6.13% total error rate (TER) on the XY-axis but with a high variance across different axes. Using data from all positions with gravity rotation can achieve 12.6% TER with a low statistical variance."],"dc:description.award":["Outstanding Thesis"],"dc:description.uri":["http://archive.org/details/evaluationofdatp1094541429"],"dc:identifier.uri":["https://hdl.handle.net/10945/41429"],"dc:publisher":["Monterey, California: Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Smartphone authentication","accelerometer gait recognition","signal processing","quaternion rotation","gravity calibration","machine learning","support vector machine","k-nearest neighbors"],"dc:title":["Evaluation of data processing techniques for unobtrusive gait authentication"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Computer Science"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master Of Science In Computer Science"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:34:46Z"}