{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/42689"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/42689","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Mandibular Advancing Positive Pressure Apnea Remediation Device (MAPPARD)","abstract":"Current research has shown that an increasing number of returning troops from deployments are being diagnosed with obstructed sleep apnea (OSA). OSA causes excessive daytime sleepiness that can endanger the readiness of Soldiers by impacting concentration, decision-making skills, personality change, hypertension, depression, headaches and has been shown to contribute to cardiovascular disease. A main factor for remediation of OSA is Soldier’s compliance with prescribed treatment plans. The two most popular methods for OSA treatment are continuous positive airway pressure (CPAP) and the Mandibular Advancing Device (MAD). Both of these devices have known compliance issues, which keep treatment of OSA to roughly 60 percent of those prescribed. We utilized a parameterized upper airway fluid structure–interaction (FSI) simulation to validate our hybrid OSA device (MAPPARD), which addressed the compliance issues found in typical OSA treatment devices. While being 25 percent less advanced than the MAD device and 50 percent less pressure than the CPAP device, our MAPPARD performed better than either current device, thus showing potential to improve Soldier treatment compliance. This study contributes to the ongoing exploration of the role of modeling and simulations for testing and evaluation of medical devices.","abstract_html":"Current research has shown that an increasing number of returning troops from deployments are being diagnosed with obstructed sleep apnea (OSA). OSA causes excessive daytime sleepiness that can endanger the readiness of Soldiers by impacting concentration, decision-making skills, personality change, hypertension, depression, headaches and has been shown to contribute to cardiovascular disease. A main factor for remediation of OSA is Soldier’s compliance with prescribed treatment plans. The two most popular methods for OSA treatment are continuous positive airway pressure (CPAP) and the Mandibular Advancing Device (MAD). Both of these devices have known compliance issues, which keep treatment of OSA to roughly 60 percent of those prescribed. We utilized a parameterized upper airway fluid structure–interaction (FSI) simulation to validate our hybrid OSA device (MAPPARD), which addressed the compliance issues found in typical OSA treatment devices. While being 25 percent less advanced than the MAD device and 50 percent less pressure than the CPAP device, our MAPPARD performed better than either current device, thus showing potential to improve Soldier treatment compliance. This study contributes to the ongoing exploration of the role of modeling and simulations for testing and evaluation of medical devices.","abstract_has_math":false,"creators":["Morehead, Benjamin T."],"institution":"Monterey, California: Naval Postgraduate School","degree_name":"Master of Science in Modeling, Virtual Environments and Simulation","degree_level":"Masters","degree_discipline":"Modeling, Virtual Environments, and Simulation Institute (MOVES)","degree_department":"Computer Science","school":null,"contributors":[],"advisors":["Sullivan, Joseph A."],"committee_chairs":[],"committee_members":["Weekley, Jeffrey D."],"year":2014,"date_issued":"2014-06","date_published":"2014-06","updated_at":"2026-11-19T06:35:03Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/42689","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/42689","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F42689","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F42689","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sullivan, Joseph A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Weekley, Jeffrey D."]},{"key":"dc:contributor.department","label":"Department","values":["Computer Science"]},{"key":"dc:creator","label":"Author","values":["Morehead, Benjamin T."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["June 2014"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-08-13T20:17:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-08-13T20:17:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Modeling, Virtual Environments, and Simulation Institute (MOVES)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Modeling, Virtual Environments and Simulation"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Obstructed sleep apnea","remediation devices","modeling and simulations","health care simulations","mandibular advancing positive pressure apnea remediation device(MAPPARD)","mandibular advancing device(MAD)","obstructed sleep apnea (OSA)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/42689"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Current research has shown that an increasing number of returning troops from deployments are being diagnosed with obstructed sleep apnea (OSA). OSA causes excessive daytime sleepiness that can endanger the readiness of Soldiers by impacting concentration, decision-making skills, personality change, hypertension, depression, headaches and has been shown to contribute to cardiovascular disease. A main factor for remediation of OSA is Soldier’s compliance with prescribed treatment plans. The two most popular methods for OSA treatment are continuous positive airway pressure (CPAP) and the Mandibular Advancing Device (MAD). Both of these devices have known compliance issues, which keep treatment of OSA to roughly 60 percent of those prescribed. We utilized a parameterized upper airway fluid structure–interaction (FSI) simulation to validate our hybrid OSA device (MAPPARD), which addressed the compliance issues found in typical OSA treatment devices. While being 25 percent less advanced than the MAD device and 50 percent less pressure than the CPAP device, our MAPPARD performed better than either current device, thus showing potential to improve Soldier treatment compliance. This study contributes to the ongoing exploration of the role of modeling and simulations for testing and evaluation of medical devices."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/mandibularadvanc1094542689"]},{"key":"dc:title","label":"Title","values":["Mandibular Advancing Positive Pressure Apnea Remediation Device (MAPPARD)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Major, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sullivan, Joseph A."],"dc:contributor.committeemember":["Weekley, Jeffrey D."],"dc:contributor.department":["Computer Science"],"dc:creator":["Morehead, Benjamin T."],"dc:date":["June 2014"],"dc:date.accessioned":["2014-08-13T20:17:52Z"],"dc:date.available":["2014-08-13T20:17:52Z"],"dc:date.issued":["2014-06"],"dc:description.abstract":["Current research has shown that an increasing number of returning troops from deployments are being diagnosed with obstructed sleep apnea (OSA). OSA causes excessive daytime sleepiness that can endanger the readiness of Soldiers by impacting concentration, decision-making skills, personality change, hypertension, depression, headaches and has been shown to contribute to cardiovascular disease. A main factor for remediation of OSA is Soldier’s compliance with prescribed treatment plans. The two most popular methods for OSA treatment are continuous positive airway pressure (CPAP) and the Mandibular Advancing Device (MAD). Both of these devices have known compliance issues, which keep treatment of OSA to roughly 60 percent of those prescribed. We utilized a parameterized upper airway fluid structure–interaction (FSI) simulation to validate our hybrid OSA device (MAPPARD), which addressed the compliance issues found in typical OSA treatment devices. While being 25 percent less advanced than the MAD device and 50 percent less pressure than the CPAP device, our MAPPARD performed better than either current device, thus showing potential to improve Soldier treatment compliance. This study contributes to the ongoing exploration of the role of modeling and simulations for testing and evaluation of medical devices."],"dc:description.uri":["http://archive.org/details/mandibularadvanc1094542689"],"dc:identifier.uri":["https://hdl.handle.net/10945/42689"],"dc:publisher":["Monterey, California: Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Obstructed sleep apnea","remediation devices","modeling and simulations","health care simulations","mandibular advancing positive pressure apnea remediation device(MAPPARD)","mandibular advancing device(MAD)","obstructed sleep apnea (OSA)"],"dc:title":["Mandibular Advancing Positive Pressure Apnea Remediation Device (MAPPARD)"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Major, United States Army"],"thesis:degree_discipline":["Modeling, Virtual Environments, and Simulation Institute (MOVES)"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Modeling, Virtual Environments and Simulation"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:35:03Z"}