{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/42844"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/42844","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Comparison of a pin stack to a conventional stack in a thermoacoustic prime mover","abstract":"This thesis compares the pin stack with a conventional rolled stack for a thermoacoustic prime mover. A pin stack is a new geometry for stacks used in thermoacoustic engines consisting of a lattice of small wires which are spaced about a thermal penetration depth apart. Computer simulations were conducted on a variety of pin stack geometries and operating parameters. Results indicate that the modeling program, DeltaE, agrees with the experimental results for conventional stacks, that the pin stack decreases viscous energy losses, and greatly increases the efficiency of the thermoacoustic engine over a large range of mean pressures. The pin stack performance was found to be more sensitive than the conventional stack to changes in thermal and viscous penetration depths of the fluid.","abstract_html":"This thesis compares the pin stack with a conventional rolled stack for a thermoacoustic prime mover. A pin stack is a new geometry for stacks used in thermoacoustic engines consisting of a lattice of small wires which are spaced about a thermal penetration depth apart. Computer simulations were conducted on a variety of pin stack geometries and operating parameters. Results indicate that the modeling program, DeltaE, agrees with the experimental results for conventional stacks, that the pin stack decreases viscous energy losses, and greatly increases the efficiency of the thermoacoustic engine over a large range of mean pressures. The pin stack performance was found to be more sensitive than the conventional stack to changes in thermal and viscous penetration depths of the fluid.","abstract_has_math":false,"creators":["Nessler, F. Scott"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Keolian, Robert"],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994-12","date_published":"1994-12","updated_at":"2026-11-21T22:42:37Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640639767"],"render_values":[{"text":"ocn640639767","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/42844","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/42844","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F42844","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F42844","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Keolian, Robert"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Nessler, F. Scott"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1994"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-08-13T20:26:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-08-13T20:26:47Z"]},{"key":"dc:date.issued","label":"Date","values":["1994-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["NA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["ocn640639767"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/42844"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis compares the pin stack with a conventional rolled stack for a thermoacoustic prime mover. A pin stack is a new geometry for stacks used in thermoacoustic engines consisting of a lattice of small wires which are spaced about a thermal penetration depth apart. Computer simulations were conducted on a variety of pin stack geometries and operating parameters. Results indicate that the modeling program, DeltaE, agrees with the experimental results for conventional stacks, that the pin stack decreases viscous energy losses, and greatly increases the efficiency of the thermoacoustic engine over a large range of mean pressures. The pin stack performance was found to be more sensitive than the conventional stack to changes in thermal and viscous penetration depths of the fluid."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/comparisonofpins1094542844"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["55 p."]},{"key":"dc:title","label":"Title","values":["Comparison of a pin stack to a conventional stack in a thermoacoustic prime mover"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["U.S. Navy (USN) author"]}]}],"canonical_facts":{"dc:contributor.advisor":["Keolian, Robert"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Nessler, F. Scott"],"dc:date":["December 1994"],"dc:date.accessioned":["2014-08-13T20:26:47Z"],"dc:date.available":["2014-08-13T20:26:47Z"],"dc:date.issued":["1994-12"],"dc:description.abstract":["This thesis compares the pin stack with a conventional rolled stack for a thermoacoustic prime mover. A pin stack is a new geometry for stacks used in thermoacoustic engines consisting of a lattice of small wires which are spaced about a thermal penetration depth apart. Computer simulations were conducted on a variety of pin stack geometries and operating parameters. Results indicate that the modeling program, DeltaE, agrees with the experimental results for conventional stacks, that the pin stack decreases viscous energy losses, and greatly increases the efficiency of the thermoacoustic engine over a large range of mean pressures. The pin stack performance was found to be more sensitive than the conventional stack to changes in thermal and viscous penetration depths of the fluid."],"dc:description.uri":["http://archive.org/details/comparisonofpins1094542844"],"dc:format.extent":["55 p."],"dc:identifier.oclc":["ocn640639767"],"dc:identifier.uri":["https://hdl.handle.net/10945/42844"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["NA"],"dc:title":["Comparison of a pin stack to a conventional stack in a thermoacoustic prime mover"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["U.S. Navy (USN) author"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T22:42:37Z"}