{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/4296"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/4296","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Flow study of a novel ionizer configuration with testing apparatus","abstract":"Micro-satellites require a propulsion system that minimizes mass and size while maximizing performance. Ion propulsion engines may be the most scalable pending reductions in ionizer size. This work explores a new ionization chamber concept. This thesis reports on the ionization of Argon, an alternative propellant to Xenon, which has been achieved at relatively low voltages with locally designed and manufactured Micro-Structured Electrode (MSE) Arrays. Testing was done with the gas flowing through the array holes, simulating the actual space environment as in an operating ion thruster. With argon flowing, breakdown has been achieved at voltages between 230 and 350 volts depending on chamber pressure, and array insulation thickness and hole size. The breakdown voltage in argon gas was higher (between 15 and 100 volts) with the flow than that without for the same wafer, and always higher for the smaller (0.127 mm vs. 0.381 mm) insulation thickness tested. No breakdown was observed when the cathode was located upstream.","abstract_html":"Micro-satellites require a propulsion system that minimizes mass and size while maximizing performance. Ion propulsion engines may be the most scalable pending reductions in ionizer size. This work explores a new ionization chamber concept. This thesis reports on the ionization of Argon, an alternative propellant to Xenon, which has been achieved at relatively low voltages with locally designed and manufactured Micro-Structured Electrode (MSE) Arrays. Testing was done with the gas flowing through the array holes, simulating the actual space environment as in an operating ion thruster. With argon flowing, breakdown has been achieved at voltages between 230 and 350 volts depending on chamber pressure, and array insulation thickness and hole size. The breakdown voltage in argon gas was higher (between 15 and 100 volts) with the flow than that without for the same wafer, and always higher for the smaller (0.127 mm vs. 0.381 mm) insulation thickness tested. No breakdown was observed when the cathode was located upstream.","abstract_has_math":false,"creators":["Armstrong, John D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Astronautical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Biblarz, Oscar","Sinibaldi, Jose"],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008-03","date_published":"2008-03","updated_at":"2026-11-26T00:16:55Z","subjects":["Microspacecraft","Rockets (Aeronautics)","Ionization phenomena","Ionization of gases","Ion rockets","Plasma (Ionized gases)","Conductivity"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["226967843"],"render_values":[{"text":"226967843","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/4296","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/4296","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F4296","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F4296","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Biblarz, Oscar","Sinibaldi, Jose"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Armstrong, John D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:41:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:41:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-03"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Microspacecraft","Rockets (Aeronautics)","Ionization phenomena","Ionization of gases","Ion rockets","Plasma (Ionized gases)","Conductivity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["226967843"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/4296"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Micro-satellites require a propulsion system that minimizes mass and size while maximizing performance. Ion propulsion engines may be the most scalable pending reductions in ionizer size. This work explores a new ionization chamber concept. This thesis reports on the ionization of Argon, an alternative propellant to Xenon, which has been achieved at relatively low voltages with locally designed and manufactured Micro-Structured Electrode (MSE) Arrays. Testing was done with the gas flowing through the array holes, simulating the actual space environment as in an operating ion thruster. With argon flowing, breakdown has been achieved at voltages between 230 and 350 volts depending on chamber pressure, and array insulation thickness and hole size. The breakdown voltage in argon gas was higher (between 15 and 100 volts) with the flow than that without for the same wafer, and always higher for the smaller (0.127 mm vs. 0.381 mm) insulation thickness tested. No breakdown was observed when the cathode was located upstream."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/flowstudyofnovel109454296"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 67 p. : ill. (some col.) ;"]},{"key":"dc:title","label":"Title","values":["Flow study of a novel ionizer configuration with testing apparatus"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["US Navy (USN) author."]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Biblarz, Oscar","Sinibaldi, Jose"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Armstrong, John D."],"dc:date.accessioned":["2012-03-14T17:41:25Z"],"dc:date.available":["2012-03-14T17:41:25Z"],"dc:date.issued":["2008-03"],"dc:description.abstract":["Micro-satellites require a propulsion system that minimizes mass and size while maximizing performance. Ion propulsion engines may be the most scalable pending reductions in ionizer size. This work explores a new ionization chamber concept. This thesis reports on the ionization of Argon, an alternative propellant to Xenon, which has been achieved at relatively low voltages with locally designed and manufactured Micro-Structured Electrode (MSE) Arrays. Testing was done with the gas flowing through the array holes, simulating the actual space environment as in an operating ion thruster. With argon flowing, breakdown has been achieved at voltages between 230 and 350 volts depending on chamber pressure, and array insulation thickness and hole size. The breakdown voltage in argon gas was higher (between 15 and 100 volts) with the flow than that without for the same wafer, and always higher for the smaller (0.127 mm vs. 0.381 mm) insulation thickness tested. No breakdown was observed when the cathode was located upstream."],"dc:description.uri":["http://archive.org/details/flowstudyofnovel109454296"],"dc:format.extent":["xiv, 67 p. : ill. (some col.) ;"],"dc:identifier.oclc":["226967843"],"dc:identifier.uri":["https://hdl.handle.net/10945/4296"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Microspacecraft","Rockets (Aeronautics)","Ionization phenomena","Ionization of gases","Ion rockets","Plasma (Ionized gases)","Conductivity"],"dc:title":["Flow study of a novel ionizer configuration with testing apparatus"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["US Navy (USN) author."],"local:etd.verified":["no"],"thesis:degree_discipline":["Astronautical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:16:55Z"}