{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/4309"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/4309","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Shipboard aggregate power monitoring","abstract":"Modern naval warships rely on vast arrays of sensor networks to evaluate the performance of mission critical systems. Although these sensor networks enable increased levels of automation, they are costly to install and to maintain. The power distribution network offers an alternative solution for tracking the performance of mission critical systems. Research conducted at Massachusetts Institute of Technology's Laboratory for Electromagnetic and Electronic Systems (LEES) has proven that the power distribution network contains vital information that can provide performance monitoring and automatic diagnostic functions. This thesis will address the issue of sensor-count reduction through the application of Non-Intrusive Load Monitoring (NILM) technology. Theoretical studies and field experiments will be presented in order to demonstrate the NILM's ability to correlate load activity with power measured from an aggregate level in the distribution system. Additionally, a critical evaluation is conducted on the current NILM configuration's ability to perform automated classification. Findings will be supported using data collected from NILMs monitoring power flow on board the U.S. Coast Guard Cutter ESCANABA (WMEC-907).","abstract_html":"Modern naval warships rely on vast arrays of sensor networks to evaluate the performance of mission critical systems. Although these sensor networks enable increased levels of automation, they are costly to install and to maintain. The power distribution network offers an alternative solution for tracking the performance of mission critical systems. Research conducted at Massachusetts Institute of Technology&#x27;s Laboratory for Electromagnetic and Electronic Systems (LEES) has proven that the power distribution network contains vital information that can provide performance monitoring and automatic diagnostic functions. This thesis will address the issue of sensor-count reduction through the application of Non-Intrusive Load Monitoring (NILM) technology. Theoretical studies and field experiments will be presented in order to demonstrate the NILM&#x27;s ability to correlate load activity with power measured from an aggregate level in the distribution system. Additionally, a critical evaluation is conducted on the current NILM configuration&#x27;s ability to perform automated classification. Findings will be supported using data collected from NILMs monitoring power flow on board the U.S. Coast Guard Cutter ESCANABA (WMEC-907).","abstract_has_math":false,"creators":["Douglas, Keith P."],"institution":"Monterey California. Naval Postgraduate School","degree_name":"Naval Engineer","degree_level":"Masters","degree_discipline":"Naval Engineer and Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-06","date_published":"2009-06","updated_at":"2026-11-20T22:10:55Z","subjects":["Detectors","Sensor networks"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["725416395"],"render_values":[{"text":"725416395","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/4309","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/4309","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F4309","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["CIVINS (Civilian Institutions)","Massachusetts Institute of Technology"]},{"key":"dc:creator","label":"Author","values":["Douglas, Keith P."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:41:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:41:30Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey California. Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["CIVINS (Civilian Institutions) Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Naval Engineer and Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Naval Engineer","Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Cambridge, Massachusetts : Massachusetts Institute of Technology (MIT)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Detectors","Sensor networks"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["725416395"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/4309"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["CIVINS (Civilian Institutions) Thesis document"]},{"key":"dc:description.abstract","label":"Abstract","values":["Modern naval warships rely on vast arrays of sensor networks to evaluate the performance of mission critical systems. Although these sensor networks enable increased levels of automation, they are costly to install and to maintain. The power distribution network offers an alternative solution for tracking the performance of mission critical systems. Research conducted at Massachusetts Institute of Technology's Laboratory for Electromagnetic and Electronic Systems (LEES) has proven that the power distribution network contains vital information that can provide performance monitoring and automatic diagnostic functions. This thesis will address the issue of sensor-count reduction through the application of Non-Intrusive Load Monitoring (NILM) technology. Theoretical studies and field experiments will be presented in order to demonstrate the NILM's ability to correlate load activity with power measured from an aggregate level in the distribution system. Additionally, a critical evaluation is conducted on the current NILM configuration's ability to perform automated classification. Findings will be supported using data collected from NILMs monitoring power flow on board the U.S. Coast Guard Cutter ESCANABA (WMEC-907)."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["CIVINS"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/shipboardggregat109454309"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["110 p. : col. ill."]},{"key":"dc:title","label":"Title","values":["Shipboard aggregate power monitoring"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.other":["CIVINS (Civilian Institutions)","Massachusetts Institute of Technology"],"dc:creator":["Douglas, Keith P."],"dc:date.accessioned":["2012-03-14T17:41:30Z"],"dc:date.available":["2012-03-14T17:41:30Z"],"dc:date.issued":["2009-06"],"dc:description":["CIVINS (Civilian Institutions) Thesis document"],"dc:description.abstract":["Modern naval warships rely on vast arrays of sensor networks to evaluate the performance of mission critical systems. Although these sensor networks enable increased levels of automation, they are costly to install and to maintain. The power distribution network offers an alternative solution for tracking the performance of mission critical systems. Research conducted at Massachusetts Institute of Technology's Laboratory for Electromagnetic and Electronic Systems (LEES) has proven that the power distribution network contains vital information that can provide performance monitoring and automatic diagnostic functions. This thesis will address the issue of sensor-count reduction through the application of Non-Intrusive Load Monitoring (NILM) technology. Theoretical studies and field experiments will be presented in order to demonstrate the NILM's ability to correlate load activity with power measured from an aggregate level in the distribution system. Additionally, a critical evaluation is conducted on the current NILM configuration's ability to perform automated classification. Findings will be supported using data collected from NILMs monitoring power flow on board the U.S. Coast Guard Cutter ESCANABA (WMEC-907)."],"dc:description.sponsorship":["CIVINS"],"dc:description.uri":["http://archive.org/details/shipboardggregat109454309"],"dc:format.extent":["110 p. : col. ill."],"dc:identifier.oclc":["725416395"],"dc:identifier.uri":["https://hdl.handle.net/10945/4309"],"dc:publisher":["Monterey California. Naval Postgraduate School"],"dc:relation.ispartofseries":["CIVINS (Civilian Institutions) Theses and Dissertations"],"dc:relation.orgunit":["c6eb8929-c883-4d31-84f5-166ce3ae8c52"],"dc:relation.seriesentity":["0855bc76-cf0d-4c5f-84ba-3b1c54b01904"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Detectors","Sensor networks"],"dc:title":["Shipboard aggregate power monitoring"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:etd.verified":["no"],"thesis:degree_discipline":["Naval Engineer and Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Naval Engineer","Master of Science in Mechanical Engineering"],"thesis:institution_name":["Cambridge, Massachusetts : Massachusetts Institute of Technology (MIT)"]},"updated_at":"2026-11-20T22:10:55Z"}