{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/43765"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/43765","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Effects of power pulsations on natural convection from discrete heat sources","abstract":"The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures, were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range.","abstract_html":"The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures, were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range.","abstract_has_math":false,"creators":["Larsen, Stephen"],"institution":"Monterey, California. Naval Postgraduate School","degree_name":"M.S. in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":["Joshi, Yogendra"],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991-12","date_published":"1991-12","updated_at":"2026-11-21T23:39:21Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/43765","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/43765","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F43765","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F43765","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joshi, Yogendra"]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Larsen, Stephen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["December 1991"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-11-20T21:35:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-11-20T21:35:29Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California. Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Liquid immersion cooling","Power pulsation","Temperature variation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/43765"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures, were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/effectsofpowerpu1094543765"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["253 p."]},{"key":"dc:title","label":"Title","values":["Effects of power pulsations on natural convection from discrete heat sources"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Joshi, Yogendra"],"dc:contributor.department":["Mechanical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Larsen, Stephen"],"dc:date":["December 1991"],"dc:date.accessioned":["2014-11-20T21:35:29Z"],"dc:date.available":["2014-11-20T21:35:29Z"],"dc:date.issued":["1991-12"],"dc:description.abstract":["The natural convection heat transfer from an array of heaters flush mounted on a vertical test surface in response to both step and periodic input power has been investigated. Baseline surface temperature measurements in water were obtained for several steady power inputs, ranging from 0.2 W to 1.0 W for the vertical test surface. Also, the effects of the presence of a parallel shroud near the test surface on measured temperature values were studied. The effects of periodic variations in input power on the heater element temperatures, were then examined at selected locations. The resulting transient heater temperatures were measured for various amplitudes, frequencies and average levels of the periodic input power. These transient measurements are compared with a two-dimensional numerical simulation of the relevant fluid flow and heat transfer processes. The computed heater surface temperatures supported the trends of the measurements and were within the expected range."],"dc:description.uri":["http://archive.org/details/effectsofpowerpu1094543765"],"dc:format.extent":["253 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/43765"],"dc:publisher":["Monterey, California. Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Liquid immersion cooling","Power pulsation","Temperature variation"],"dc:title":["Effects of power pulsations on natural convection from discrete heat sources"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-21T23:39:21Z"}