{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/43767"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/43767","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Emittance measurement of the Naval Postgraduate School Linear Accelerator using optical transition radiation techniques","abstract":"Using Optical Transition Radiation (OTR) beam diagnostics and Dr. Rule's clear foil interferometer analytic code, the normalized emittance of the Naval Postgraduate School (NPS) Linear Accelerator (linac) has been measured: the normalized horizontal emittance of 97 pi +/- 10 pi mm-mrad and the normalized vertical emittance of 54 pi +/- 8 pi mm-mrad. The experiment was performed independently twice using a Kapton foil/silicon mirror and a nitrocellulose foil/aluminum mirror Wartski interferometer. The Kapton foil provided an initial measurement of the emittance, and provided lessons learned for the nitrocellulose foil measurement. The emittance measurement of the NPS linac indicate that the value maybe too high for most free electron laser applications, but is very useful for radiation effect studies in high temperature superconductors, hardening, beam diagnostics, and for the production of x-rays through novel mechanisms such as transition radiation and parametric x-radiation generation. The beam divergence was determined by comparing theoretically calculated OTR patterns with the experimental data OTR patterns.","abstract_html":"Using Optical Transition Radiation (OTR) beam diagnostics and Dr. Rule&#x27;s clear foil interferometer analytic code, the normalized emittance of the Naval Postgraduate School (NPS) Linear Accelerator (linac) has been measured: the normalized horizontal emittance of 97 pi +/- 10 pi mm-mrad and the normalized vertical emittance of 54 pi +/- 8 pi mm-mrad. The experiment was performed independently twice using a Kapton foil/silicon mirror and a nitrocellulose foil/aluminum mirror Wartski interferometer. The Kapton foil provided an initial measurement of the emittance, and provided lessons learned for the nitrocellulose foil measurement. The emittance measurement of the NPS linac indicate that the value maybe too high for most free electron laser applications, but is very useful for radiation effect studies in high temperature superconductors, hardening, beam diagnostics, and for the production of x-rays through novel mechanisms such as transition radiation and parametric x-radiation generation. The beam divergence was determined by comparing theoretically calculated OTR patterns with the experimental data OTR patterns.","abstract_has_math":false,"creators":["Hellstern, Mark Joseph"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S. in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Department of Physics","school":null,"contributors":[],"advisors":["Maruyama, Xavier K."],"committee_chairs":[],"committee_members":["Buskirk, Fred R."],"year":1991,"date_issued":"1991-09","date_published":"1991-09","updated_at":"2026-11-26T00:15:05Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/43767","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/43767","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F43767","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F43767","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Maruyama, Xavier K."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Buskirk, Fred R."]},{"key":"dc:contributor.department","label":"Department","values":["Department of Physics"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Hellstern, Mark Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["September 1991"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-11-20T21:35:42Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-11-20T21:35:42Z"]},{"key":"dc:date.issued","label":"Date","values":["1991-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S. in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Optical transition radiation","Charged particle beams","Free electron lasers","Beam diagnostics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/43767"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Using Optical Transition Radiation (OTR) beam diagnostics and Dr. Rule's clear foil interferometer analytic code, the normalized emittance of the Naval Postgraduate School (NPS) Linear Accelerator (linac) has been measured: the normalized horizontal emittance of 97 pi +/- 10 pi mm-mrad and the normalized vertical emittance of 54 pi +/- 8 pi mm-mrad. The experiment was performed independently twice using a Kapton foil/silicon mirror and a nitrocellulose foil/aluminum mirror Wartski interferometer. The Kapton foil provided an initial measurement of the emittance, and provided lessons learned for the nitrocellulose foil measurement. The emittance measurement of the NPS linac indicate that the value maybe too high for most free electron laser applications, but is very useful for radiation effect studies in high temperature superconductors, hardening, beam diagnostics, and for the production of x-rays through novel mechanisms such as transition radiation and parametric x-radiation generation. The beam divergence was determined by comparing theoretically calculated OTR patterns with the experimental data OTR patterns."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/emittancemeasure1094543767"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["121 p."]},{"key":"dc:title","label":"Title","values":["Emittance measurement of the Naval Postgraduate School Linear Accelerator using optical transition radiation techniques"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Maruyama, Xavier K."],"dc:contributor.committeemember":["Buskirk, Fred R."],"dc:contributor.department":["Department of Physics"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Hellstern, Mark Joseph"],"dc:date":["September 1991"],"dc:date.accessioned":["2014-11-20T21:35:42Z"],"dc:date.available":["2014-11-20T21:35:42Z"],"dc:date.issued":["1991-09"],"dc:description.abstract":["Using Optical Transition Radiation (OTR) beam diagnostics and Dr. Rule's clear foil interferometer analytic code, the normalized emittance of the Naval Postgraduate School (NPS) Linear Accelerator (linac) has been measured: the normalized horizontal emittance of 97 pi +/- 10 pi mm-mrad and the normalized vertical emittance of 54 pi +/- 8 pi mm-mrad. The experiment was performed independently twice using a Kapton foil/silicon mirror and a nitrocellulose foil/aluminum mirror Wartski interferometer. The Kapton foil provided an initial measurement of the emittance, and provided lessons learned for the nitrocellulose foil measurement. The emittance measurement of the NPS linac indicate that the value maybe too high for most free electron laser applications, but is very useful for radiation effect studies in high temperature superconductors, hardening, beam diagnostics, and for the production of x-rays through novel mechanisms such as transition radiation and parametric x-radiation generation. The beam divergence was determined by comparing theoretically calculated OTR patterns with the experimental data OTR patterns."],"dc:description.uri":["http://archive.org/details/emittancemeasure1094543767"],"dc:format.extent":["121 p."],"dc:identifier.uri":["https://hdl.handle.net/10945/43767"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Optical transition radiation","Charged particle beams","Free electron lasers","Beam diagnostics"],"dc:title":["Emittance measurement of the Naval Postgraduate School Linear Accelerator using optical transition radiation techniques"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S. in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:15:05Z"}