{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/43942"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/43942","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Performance and reliability of exhaust gas waste heat recovery units","abstract":"This thesis presents the effect of exhaust tube length-to-diameter (L/d) ratio, jacket-to-tube diameter (D/d) ratio, coolant inlet and outlet placements, exhaust gas swirling conditions, and tube materials (steel, copper, Inconel, and ceramic) on heat recovery performance, exhaust side pressure drop, and temperature profile in the exhaust gas Waste Heat Recovery Unit (WHRU). Non-dimensional parametric studies of a selected counter-flow Water Jacket WHRU was conducted using analytical and Computational Fluid Dynamic (CFD) models. Exhaust gas Reynolds numbers between 20,000 and 400,000, representative of exhaust gas flow in the exhaust stacks of U.S.Marine Corps’ MEP803A diesel generators and the U.S.Navy's 501-K17 gas turbine generators, were used. Results indicate heat recovery increases with higher L/d, D/d, and swirling exhaust gases conditions but with a severe pressure drop penalty. Addition of a solid heat spreader at the exhaust gas inlet and the use of suitable tube materials were also found to influence temperature profiles in the WHRU and mitigate adverse temperature gradients to some extent without any additional pressure drop penalty. Optimal laterally shifted placement of coolant inlet and outlet was found to improve heat recovery by up to 19% and was very effective at mitigating adverse temperature profiles, which improves the reliability of exhaust gas WHRU.","abstract_html":"This thesis presents the effect of exhaust tube length-to-diameter (L/d) ratio, jacket-to-tube diameter (D/d) ratio, coolant inlet and outlet placements, exhaust gas swirling conditions, and tube materials (steel, copper, Inconel, and ceramic) on heat recovery performance, exhaust side pressure drop, and temperature profile in the exhaust gas Waste Heat Recovery Unit (WHRU). Non-dimensional parametric studies of a selected counter-flow Water Jacket WHRU was conducted using analytical and Computational Fluid Dynamic (CFD) models. Exhaust gas Reynolds numbers between 20,000 and 400,000, representative of exhaust gas flow in the exhaust stacks of U.S.Marine Corps’ MEP803A diesel generators and the U.S.Navy&#x27;s 501-K17 gas turbine generators, were used. Results indicate heat recovery increases with higher L/d, D/d, and swirling exhaust gases conditions but with a severe pressure drop penalty. Addition of a solid heat spreader at the exhaust gas inlet and the use of suitable tube materials were also found to influence temperature profiles in the WHRU and mitigate adverse temperature gradients to some extent without any additional pressure drop penalty. Optimal laterally shifted placement of coolant inlet and outlet was found to improve heat recovery by up to 19% and was very effective at mitigating adverse temperature profiles, which improves the reliability of exhaust gas WHRU.","abstract_has_math":false,"creators":["Koh, Chuan Heng Erik"],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical and Aerospace Engineering (MAE)","school":null,"contributors":[],"advisors":["Sathe, Sanjeev B.","Millsaps, Knox T."],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-09","date_published":"2014-09","updated_at":"2026-11-26T00:11:43Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/43942","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/43942","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F43942","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F43942","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sathe, Sanjeev B.","Millsaps, Knox T."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical and Aerospace Engineering (MAE)"]},{"key":"dc:creator","label":"Author","values":["Koh, Chuan Heng Erik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Sep-14"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-12-05T20:10:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-12-05T20:10:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["waste heat recovery","heat recovery performance","swirling flow","pressure drop penalty","temperature profiles","thermal stresses"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/43942"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the effect of exhaust tube length-to-diameter (L/d) ratio, jacket-to-tube diameter (D/d) ratio, coolant inlet and outlet placements, exhaust gas swirling conditions, and tube materials (steel, copper, Inconel, and ceramic) on heat recovery performance, exhaust side pressure drop, and temperature profile in the exhaust gas Waste Heat Recovery Unit (WHRU). Non-dimensional parametric studies of a selected counter-flow Water Jacket WHRU was conducted using analytical and Computational Fluid Dynamic (CFD) models. Exhaust gas Reynolds numbers between 20,000 and 400,000, representative of exhaust gas flow in the exhaust stacks of U.S.Marine Corps’ MEP803A diesel generators and the U.S.Navy's 501-K17 gas turbine generators, were used. Results indicate heat recovery increases with higher L/d, D/d, and swirling exhaust gases conditions but with a severe pressure drop penalty. Addition of a solid heat spreader at the exhaust gas inlet and the use of suitable tube materials were also found to influence temperature profiles in the WHRU and mitigate adverse temperature gradients to some extent without any additional pressure drop penalty. Optimal laterally shifted placement of coolant inlet and outlet was found to improve heat recovery by up to 19% and was very effective at mitigating adverse temperature profiles, which improves the reliability of exhaust gas WHRU."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/performancendrel1094543942"]},{"key":"dc:title","label":"Title","values":["Performance and reliability of exhaust gas waste heat recovery units"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Military Expert 5, Republic of Singapore Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sathe, Sanjeev B.","Millsaps, Knox T."],"dc:contributor.department":["Mechanical and Aerospace Engineering (MAE)"],"dc:creator":["Koh, Chuan Heng Erik"],"dc:date":["Sep-14"],"dc:date.accessioned":["2014-12-05T20:10:27Z"],"dc:date.available":["2014-12-05T20:10:27Z"],"dc:date.issued":["2014-09"],"dc:description.abstract":["This thesis presents the effect of exhaust tube length-to-diameter (L/d) ratio, jacket-to-tube diameter (D/d) ratio, coolant inlet and outlet placements, exhaust gas swirling conditions, and tube materials (steel, copper, Inconel, and ceramic) on heat recovery performance, exhaust side pressure drop, and temperature profile in the exhaust gas Waste Heat Recovery Unit (WHRU). Non-dimensional parametric studies of a selected counter-flow Water Jacket WHRU was conducted using analytical and Computational Fluid Dynamic (CFD) models. Exhaust gas Reynolds numbers between 20,000 and 400,000, representative of exhaust gas flow in the exhaust stacks of U.S.Marine Corps’ MEP803A diesel generators and the U.S.Navy's 501-K17 gas turbine generators, were used. Results indicate heat recovery increases with higher L/d, D/d, and swirling exhaust gases conditions but with a severe pressure drop penalty. Addition of a solid heat spreader at the exhaust gas inlet and the use of suitable tube materials were also found to influence temperature profiles in the WHRU and mitigate adverse temperature gradients to some extent without any additional pressure drop penalty. Optimal laterally shifted placement of coolant inlet and outlet was found to improve heat recovery by up to 19% and was very effective at mitigating adverse temperature profiles, which improves the reliability of exhaust gas WHRU."],"dc:description.uri":["http://archive.org/details/performancendrel1094543942"],"dc:identifier.uri":["https://hdl.handle.net/10945/43942"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["waste heat recovery","heat recovery performance","swirling flow","pressure drop penalty","temperature profiles","thermal stresses"],"dc:title":["Performance and reliability of exhaust gas waste heat recovery units"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Military Expert 5, Republic of Singapore Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:11:43Z"}