{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/4476"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/4476","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Characterization of zinc selenide-based ultraviolet detectors","abstract":"Wide bandgap semiconductors such as Zinc Selenide (ZnSe) have become popular for ultraviolet (UV) photodetectors. ZnSe has a higher photosensitivity compared to silicon-based detectors due to its larger bandgap. Its capability of turning optical power into valuable electrical signals makes it suitable for measurement and recording of UV exposure for military personnel. The prospect of ZnSe's unique medical and military applications has been the driving force of this study. This thesis presents characterization of performance of UV detectors using ZnSe-based Schottky diodes. There are a total of 15 photodetectors involved in this study. Three sets, each consisting of five photodetectors, were designed to detect Ultraviolet-A (320-400 nm), Ultraviolet-B (290-320 nm) and combination of both (UV-A and UV-B) wavelength ranges. The 15 detectors were analyzed for their photosensitivity using a photocurrent measurement system. Each diode's responsivity (ampere per watt) was determined as a function of wavelength of the incident radiation. The second part of the characterization process includes the determination of the current-voltage (IV) characteristics of the photodetectors. Each photodiode's current response was plotted as a function of both reverse and forward biased voltages and compared with the expected behavior.","abstract_html":"Wide bandgap semiconductors such as Zinc Selenide (ZnSe) have become popular for ultraviolet (UV) photodetectors. ZnSe has a higher photosensitivity compared to silicon-based detectors due to its larger bandgap. Its capability of turning optical power into valuable electrical signals makes it suitable for measurement and recording of UV exposure for military personnel. The prospect of ZnSe&#x27;s unique medical and military applications has been the driving force of this study. This thesis presents characterization of performance of UV detectors using ZnSe-based Schottky diodes. There are a total of 15 photodetectors involved in this study. Three sets, each consisting of five photodetectors, were designed to detect Ultraviolet-A (320-400 nm), Ultraviolet-B (290-320 nm) and combination of both (UV-A and UV-B) wavelength ranges. The 15 detectors were analyzed for their photosensitivity using a photocurrent measurement system. Each diode&#x27;s responsivity (ampere per watt) was determined as a function of wavelength of the incident radiation. The second part of the characterization process includes the determination of the current-voltage (IV) characteristics of the photodetectors. Each photodiode&#x27;s current response was plotted as a function of both reverse and forward biased voltages and compared with the expected behavior.","abstract_has_math":false,"creators":["Naval, Victoriano C."],"institution":"Monterey, California: Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Karunasiri, Gamani"],"committee_chairs":[],"committee_members":["Smith, Craig"],"year":2009,"date_issued":"2009-12","date_published":"2009-12","updated_at":"2026-11-19T06:35:40Z","subjects":["Zinc selenide","Optical detectors","Melanoma","Physics"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["502440501"],"render_values":[{"text":"502440501","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/4476","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/4476","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F4476","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Karunasiri, Gamani"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Smith, Craig"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Naval, Victoriano C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:42:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:42:01Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, California: Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Zinc selenide","Optical detectors","Melanoma","Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["502440501"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/4476"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Wide bandgap semiconductors such as Zinc Selenide (ZnSe) have become popular for ultraviolet (UV) photodetectors. ZnSe has a higher photosensitivity compared to silicon-based detectors due to its larger bandgap. Its capability of turning optical power into valuable electrical signals makes it suitable for measurement and recording of UV exposure for military personnel. The prospect of ZnSe's unique medical and military applications has been the driving force of this study. This thesis presents characterization of performance of UV detectors using ZnSe-based Schottky diodes. There are a total of 15 photodetectors involved in this study. Three sets, each consisting of five photodetectors, were designed to detect Ultraviolet-A (320-400 nm), Ultraviolet-B (290-320 nm) and combination of both (UV-A and UV-B) wavelength ranges. The 15 detectors were analyzed for their photosensitivity using a photocurrent measurement system. Each diode's responsivity (ampere per watt) was determined as a function of wavelength of the incident radiation. The second part of the characterization process includes the determination of the current-voltage (IV) characteristics of the photodetectors. Each photodiode's current response was plotted as a function of both reverse and forward biased voltages and compared with the expected behavior."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/characterization109454476"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 41 p. : col. ill. ;"]},{"key":"dc:title","label":"Title","values":["Characterization of zinc selenide-based ultraviolet detectors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["US Navy (USN) author."]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Karunasiri, Gamani"],"dc:contributor.committeemember":["Smith, Craig"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Naval, Victoriano C."],"dc:date.accessioned":["2012-03-14T17:42:01Z"],"dc:date.available":["2012-03-14T17:42:01Z"],"dc:date.issued":["2009-12"],"dc:description.abstract":["Wide bandgap semiconductors such as Zinc Selenide (ZnSe) have become popular for ultraviolet (UV) photodetectors. ZnSe has a higher photosensitivity compared to silicon-based detectors due to its larger bandgap. Its capability of turning optical power into valuable electrical signals makes it suitable for measurement and recording of UV exposure for military personnel. The prospect of ZnSe's unique medical and military applications has been the driving force of this study. This thesis presents characterization of performance of UV detectors using ZnSe-based Schottky diodes. There are a total of 15 photodetectors involved in this study. Three sets, each consisting of five photodetectors, were designed to detect Ultraviolet-A (320-400 nm), Ultraviolet-B (290-320 nm) and combination of both (UV-A and UV-B) wavelength ranges. The 15 detectors were analyzed for their photosensitivity using a photocurrent measurement system. Each diode's responsivity (ampere per watt) was determined as a function of wavelength of the incident radiation. The second part of the characterization process includes the determination of the current-voltage (IV) characteristics of the photodetectors. Each photodiode's current response was plotted as a function of both reverse and forward biased voltages and compared with the expected behavior."],"dc:description.uri":["http://archive.org/details/characterization109454476"],"dc:format.extent":["xiv, 41 p. : col. ill. ;"],"dc:identifier.oclc":["502440501"],"dc:identifier.uri":["https://hdl.handle.net/10945/4476"],"dc:publisher":["Monterey, California: Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Zinc selenide","Optical detectors","Melanoma","Physics"],"dc:title":["Characterization of zinc selenide-based ultraviolet detectors"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["US Navy (USN) author."],"local:etd.verified":["no"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:35:40Z"}