{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/45816"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/45816","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Optimal placement of non-intrusive waste heat recovery devices in exhaust ducts","abstract":"The Secretary of the Navy has ordered the U.S. Navy and Marine Corps to reduce energy usage. This study explores how to optimize placement and size of a non-intrusive waste heat recovery device for energy recovery in exhaust ducts. Additionally, it explores the effect that a device has on the exhaust infrared signature by analyzing the change in the bulk temperature at the exhaust outlet. Optimal device placement and size is dependent on duct geometry, external heat transfer coefficient, and flow characteristics, namely Reynolds number. Infrared signature intensity reductions of 1–14% are only achievable with unpractically long thermoelectric generator devices and high external heat transfer coefficients. Doubling the external heat transfer coefficient increases heat recovery by 15–30% for low Reynolds number flows (104) and 75–90% for high Reynolds number flows (105~106). In low Reynolds number flows (~104), device position can account for a 75% change in energy recovery whereas high Reynolds number flows (~106) have unexpected areas of higher heat transfer. Position changes can increase heat recovery 10–70%, while increasing device size may only marginally improve results. Identifying local maxima for heat transfer, especially in high Reynolds number flows (~106), is counterintuitive because of unexpected recirculation zone effects.","abstract_html":"The Secretary of the Navy has ordered the U.S. Navy and Marine Corps to reduce energy usage. This study explores how to optimize placement and size of a non-intrusive waste heat recovery device for energy recovery in exhaust ducts. Additionally, it explores the effect that a device has on the exhaust infrared signature by analyzing the change in the bulk temperature at the exhaust outlet. Optimal device placement and size is dependent on duct geometry, external heat transfer coefficient, and flow characteristics, namely Reynolds number. Infrared signature intensity reductions of 1–14% are only achievable with unpractically long thermoelectric generator devices and high external heat transfer coefficients. Doubling the external heat transfer coefficient increases heat recovery by 15–30% for low Reynolds number flows (104) and 75–90% for high Reynolds number flows (105~106). In low Reynolds number flows (~104), device position can account for a 75% change in energy recovery whereas high Reynolds number flows (~106) have unexpected areas of higher heat transfer. Position changes can increase heat recovery 10–70%, while increasing device size may only marginally improve results. Identifying local maxima for heat transfer, especially in high Reynolds number flows (~106), is counterintuitive because of unexpected recirculation zone effects.","abstract_has_math":false,"creators":["Bohning, Ryan S."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical and Aerospace Engineering (MAE)","school":null,"contributors":[],"advisors":["Sathe, Sanjeev B.","Hobson, Garth V."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-06","date_published":"2015-06","updated_at":"2026-11-19T06:35:40Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/45816","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/45816","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F45816","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F45816","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Sathe, Sanjeev B.","Hobson, Garth V."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical and Aerospace Engineering (MAE)"]},{"key":"dc:creator","label":"Author","values":["Bohning, Ryan S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-08-05T23:05:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-08-05T23:05:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["fcd0a3e4-3370-4559-99ee-72c50043ad3c"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Waste heat recovery","thermoelectric generator","optimization","IR signature","heat transfer","thermal stress"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/45816"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Reissued 26 Aug to correct math symbol mechanical mistranslations throughout."]},{"key":"dc:description.abstract","label":"Abstract","values":["The Secretary of the Navy has ordered the U.S. Navy and Marine Corps to reduce energy usage. This study explores how to optimize placement and size of a non-intrusive waste heat recovery device for energy recovery in exhaust ducts. Additionally, it explores the effect that a device has on the exhaust infrared signature by analyzing the change in the bulk temperature at the exhaust outlet. Optimal device placement and size is dependent on duct geometry, external heat transfer coefficient, and flow characteristics, namely Reynolds number. Infrared signature intensity reductions of 1–14% are only achievable with unpractically long thermoelectric generator devices and high external heat transfer coefficients. Doubling the external heat transfer coefficient increases heat recovery by 15–30% for low Reynolds number flows (104) and 75–90% for high Reynolds number flows (105~106). In low Reynolds number flows (~104), device position can account for a 75% change in energy recovery whereas high Reynolds number flows (~106) have unexpected areas of higher heat transfer. Position changes can increase heat recovery 10–70%, while increasing device size may only marginally improve results. Identifying local maxima for heat transfer, especially in high Reynolds number flows (~106), is counterintuitive because of unexpected recirculation zone effects."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/optimalplacement1094545816"]},{"key":"dc:title","label":"Title","values":["Optimal placement of non-intrusive waste heat recovery devices in exhaust ducts"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Sathe, Sanjeev B.","Hobson, Garth V."],"dc:contributor.department":["Mechanical and Aerospace Engineering (MAE)"],"dc:creator":["Bohning, Ryan S."],"dc:date.accessioned":["2015-08-05T23:05:17Z"],"dc:date.available":["2015-08-05T23:05:17Z"],"dc:date.issued":["2015-06"],"dc:description":["Reissued 26 Aug to correct math symbol mechanical mistranslations throughout."],"dc:description.abstract":["The Secretary of the Navy has ordered the U.S. Navy and Marine Corps to reduce energy usage. This study explores how to optimize placement and size of a non-intrusive waste heat recovery device for energy recovery in exhaust ducts. Additionally, it explores the effect that a device has on the exhaust infrared signature by analyzing the change in the bulk temperature at the exhaust outlet. Optimal device placement and size is dependent on duct geometry, external heat transfer coefficient, and flow characteristics, namely Reynolds number. Infrared signature intensity reductions of 1–14% are only achievable with unpractically long thermoelectric generator devices and high external heat transfer coefficients. Doubling the external heat transfer coefficient increases heat recovery by 15–30% for low Reynolds number flows (104) and 75–90% for high Reynolds number flows (105~106). In low Reynolds number flows (~104), device position can account for a 75% change in energy recovery whereas high Reynolds number flows (~106) have unexpected areas of higher heat transfer. Position changes can increase heat recovery 10–70%, while increasing device size may only marginally improve results. Identifying local maxima for heat transfer, especially in high Reynolds number flows (~106), is counterintuitive because of unexpected recirculation zone effects."],"dc:description.uri":["http://archive.org/details/optimalplacement1094545816"],"dc:identifier.uri":["https://hdl.handle.net/10945/45816"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["fcd0a3e4-3370-4559-99ee-72c50043ad3c"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Waste heat recovery","thermoelectric generator","optimization","IR signature","heat transfer","thermal stress"],"dc:title":["Optimal placement of non-intrusive waste heat recovery devices in exhaust ducts"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:35:40Z"}