{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/45895"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/45895","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Cost benefit analysis: closed-cell polyurethane foam use in DoD forward-deployed structures, and as an alternative building material, to reduce operational fuel demand and associated costs","abstract":"The purpose of this project is to identify the costs and benefits associated with the application of closed-cell spray foam insulation to forward-deployed, semipermanent/nonpermanent structures, and to provide recommendations regarding future integration, use, and employment. According to the Department of Defense (DOD), forward-deployed generators, used to provide power to base support activities, are the largest single consumer of fuel throughout the battlefield. Eighty percent of the energy provided by generators is assessed to power environmental control units that run incessantly due to the poor insulating properties of the structures, according to a 2010 study conducted by the Department of the Air Force Civil Engineer Support Agency. Recent DOD policy has focused more on energy use and consumption but fails to address, and provide solutions for, major consumers of fuel throughout the battlefield. The incorporation of closed-cell, spray foam insulation into legacy DOD forward-deployed construction practices yields a significant return on investment, short-payback/break-even period, and reduces mission and personnel risk to deployed military forces.","abstract_html":"The purpose of this project is to identify the costs and benefits associated with the application of closed-cell spray foam insulation to forward-deployed, semipermanent/nonpermanent structures, and to provide recommendations regarding future integration, use, and employment. According to the Department of Defense (DOD), forward-deployed generators, used to provide power to base support activities, are the largest single consumer of fuel throughout the battlefield. Eighty percent of the energy provided by generators is assessed to power environmental control units that run incessantly due to the poor insulating properties of the structures, according to a 2010 study conducted by the Department of the Air Force Civil Engineer Support Agency. Recent DOD policy has focused more on energy use and consumption but fails to address, and provide solutions for, major consumers of fuel throughout the battlefield. The incorporation of closed-cell, spray foam insulation into legacy DOD forward-deployed construction practices yields a significant return on investment, short-payback/break-even period, and reduces mission and personnel risk to deployed military forces.","abstract_has_math":false,"creators":["Marsh, Robert J.","Caballero, Steven L.","Gerry, Stephen D."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Business Administration","degree_level":"Masters","degree_discipline":"Business Administration","degree_department":null,"school":null,"contributors":[],"advisors":["Arkes, Jeremy","Landry, Steven"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-06","date_published":"2015-06","updated_at":"2026-11-19T06:35:56Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/45895","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/45895","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F45895","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Arkes, Jeremy","Landry, Steven"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Graduate School of Business & Public Policy (GSBPP)"]},{"key":"dc:creator","label":"Author","values":["Marsh, Robert J.","Caballero, Steven L.","Gerry, Stephen D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-08-05T23:05:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-08-05T23:05:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["689b9e9a-8dae-40b6-b61b-bc2662e12411"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Business Administration"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Business Administration"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["closed-cell polyurethane foam","polyurethane foam insulation","closed-cell spray foam (CCSF) insulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/45895"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this project is to identify the costs and benefits associated with the application of closed-cell spray foam insulation to forward-deployed, semipermanent/nonpermanent structures, and to provide recommendations regarding future integration, use, and employment. According to the Department of Defense (DOD), forward-deployed generators, used to provide power to base support activities, are the largest single consumer of fuel throughout the battlefield. Eighty percent of the energy provided by generators is assessed to power environmental control units that run incessantly due to the poor insulating properties of the structures, according to a 2010 study conducted by the Department of the Air Force Civil Engineer Support Agency. Recent DOD policy has focused more on energy use and consumption but fails to address, and provide solutions for, major consumers of fuel throughout the battlefield. The incorporation of closed-cell, spray foam insulation into legacy DOD forward-deployed construction practices yields a significant return on investment, short-payback/break-even period, and reduces mission and personnel risk to deployed military forces."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/costbenefitnalys1094545895"]},{"key":"dc:title","label":"Title","values":["Cost benefit analysis: closed-cell polyurethane foam use in DoD forward-deployed structures, and as an alternative building material, to reduce operational fuel demand and associated costs"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant Commander, United States Navy","Lieutenant, United States Navy","Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Arkes, Jeremy","Landry, Steven"],"dc:contributor.other":["Graduate School of Business & Public Policy (GSBPP)"],"dc:creator":["Marsh, Robert J.","Caballero, Steven L.","Gerry, Stephen D."],"dc:date.accessioned":["2015-08-05T23:05:50Z"],"dc:date.available":["2015-08-05T23:05:50Z"],"dc:date.issued":["2015-06"],"dc:description.abstract":["The purpose of this project is to identify the costs and benefits associated with the application of closed-cell spray foam insulation to forward-deployed, semipermanent/nonpermanent structures, and to provide recommendations regarding future integration, use, and employment. According to the Department of Defense (DOD), forward-deployed generators, used to provide power to base support activities, are the largest single consumer of fuel throughout the battlefield. Eighty percent of the energy provided by generators is assessed to power environmental control units that run incessantly due to the poor insulating properties of the structures, according to a 2010 study conducted by the Department of the Air Force Civil Engineer Support Agency. Recent DOD policy has focused more on energy use and consumption but fails to address, and provide solutions for, major consumers of fuel throughout the battlefield. The incorporation of closed-cell, spray foam insulation into legacy DOD forward-deployed construction practices yields a significant return on investment, short-payback/break-even period, and reduces mission and personnel risk to deployed military forces."],"dc:description.uri":["http://archive.org/details/costbenefitnalys1094545895"],"dc:identifier.uri":["https://hdl.handle.net/10945/45895"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["689b9e9a-8dae-40b6-b61b-bc2662e12411"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["closed-cell polyurethane foam","polyurethane foam insulation","closed-cell spray foam (CCSF) insulation"],"dc:title":["Cost benefit analysis: closed-cell polyurethane foam use in DoD forward-deployed structures, and as an alternative building material, to reduce operational fuel demand and associated costs"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant Commander, United States Navy","Lieutenant, United States Navy","Captain, United States Army"],"thesis:degree_discipline":["Business Administration"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Business Administration"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:35:56Z"}