{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/47281"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/47281","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"The effect of applied tensile stress on localized corrosion in sensitized AA5083","abstract":"This thesis describes significant changes in the type and degree of localized corrosion for sensitized AA5083 under an applied tensile stress. AA5083 is an aluminum-magnesium alloy that experiences severe intergranular corrosion and intergranular stress corrosion cracking if sensitized. In this research, AA5083-H116 plates were cut into bend-bar samples along both the rolling and transverse directions, and then sensitized to two different levels using laboratory heat treatments of 7 and 30 days at 100°C. The sensitized samples were subjected to elastic tensile loading using a 4-point bend rig while being exposed to a 0.6 molar saltwater solution. Electrochemical polarization was performed on the tensile regions of the samples while under applied stress. Potentiodynamic scans showed that although sensitization causes the most change in electrochemistry, stress does shift the Tafel plot to be more stable when comparing the values for open circuit potential, but reduces the pitting potential of the passivating oxides. Confocal microscopy showed that samples with applied tensile stress produced a much higher density of localized corrosion, including pitting and intergranular corrosion than samples without applied tensile stress. The degree of corrosion damage was slightly higher for samples loaded in the transverse direction compared to samples loaded in the longitudinal direction.","abstract_html":"This thesis describes significant changes in the type and degree of localized corrosion for sensitized AA5083 under an applied tensile stress. AA5083 is an aluminum-magnesium alloy that experiences severe intergranular corrosion and intergranular stress corrosion cracking if sensitized. In this research, AA5083-H116 plates were cut into bend-bar samples along both the rolling and transverse directions, and then sensitized to two different levels using laboratory heat treatments of 7 and 30 days at 100°C. The sensitized samples were subjected to elastic tensile loading using a 4-point bend rig while being exposed to a 0.6 molar saltwater solution. Electrochemical polarization was performed on the tensile regions of the samples while under applied stress. Potentiodynamic scans showed that although sensitization causes the most change in electrochemistry, stress does shift the Tafel plot to be more stable when comparing the values for open circuit potential, but reduces the pitting potential of the passivating oxides. Confocal microscopy showed that samples with applied tensile stress produced a much higher density of localized corrosion, including pitting and intergranular corrosion than samples without applied tensile stress. The degree of corrosion damage was slightly higher for samples loaded in the transverse direction compared to samples loaded in the longitudinal direction.","abstract_has_math":false,"creators":["Johnston, Roy T."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Mechanical Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical and Aerospace Engineering (MAE)","school":null,"contributors":[],"advisors":["Menon, Sarath K.","Brewer, Luke N."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-09","date_published":"2015-09","updated_at":"2026-11-19T06:35:56Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/47281","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/47281","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F47281","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F47281","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Menon, Sarath K.","Brewer, Luke N."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical and Aerospace Engineering (MAE)"]},{"key":"dc:creator","label":"Author","values":["Johnston, Roy T."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-11-06T18:22:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-11-06T18:22:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-09"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["fcd0a3e4-3370-4559-99ee-72c50043ad3c"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Mechanical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Aluminum alloy","AA5083","IGSCC","intergranular stress corrosion cracking","localized corrosion","sensitized aluminum"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/47281"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis describes significant changes in the type and degree of localized corrosion for sensitized AA5083 under an applied tensile stress. AA5083 is an aluminum-magnesium alloy that experiences severe intergranular corrosion and intergranular stress corrosion cracking if sensitized. In this research, AA5083-H116 plates were cut into bend-bar samples along both the rolling and transverse directions, and then sensitized to two different levels using laboratory heat treatments of 7 and 30 days at 100°C. The sensitized samples were subjected to elastic tensile loading using a 4-point bend rig while being exposed to a 0.6 molar saltwater solution. Electrochemical polarization was performed on the tensile regions of the samples while under applied stress. Potentiodynamic scans showed that although sensitization causes the most change in electrochemistry, stress does shift the Tafel plot to be more stable when comparing the values for open circuit potential, but reduces the pitting potential of the passivating oxides. Confocal microscopy showed that samples with applied tensile stress produced a much higher density of localized corrosion, including pitting and intergranular corrosion than samples without applied tensile stress. The degree of corrosion damage was slightly higher for samples loaded in the transverse direction compared to samples loaded in the longitudinal direction."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/theeffectofpplie1094547281"]},{"key":"dc:title","label":"Title","values":["The effect of applied tensile stress on localized corrosion in sensitized AA5083"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Menon, Sarath K.","Brewer, Luke N."],"dc:contributor.department":["Mechanical and Aerospace Engineering (MAE)"],"dc:creator":["Johnston, Roy T."],"dc:date.accessioned":["2015-11-06T18:22:25Z"],"dc:date.available":["2015-11-06T18:22:25Z"],"dc:date.issued":["2015-09"],"dc:description.abstract":["This thesis describes significant changes in the type and degree of localized corrosion for sensitized AA5083 under an applied tensile stress. AA5083 is an aluminum-magnesium alloy that experiences severe intergranular corrosion and intergranular stress corrosion cracking if sensitized. In this research, AA5083-H116 plates were cut into bend-bar samples along both the rolling and transverse directions, and then sensitized to two different levels using laboratory heat treatments of 7 and 30 days at 100°C. The sensitized samples were subjected to elastic tensile loading using a 4-point bend rig while being exposed to a 0.6 molar saltwater solution. Electrochemical polarization was performed on the tensile regions of the samples while under applied stress. Potentiodynamic scans showed that although sensitization causes the most change in electrochemistry, stress does shift the Tafel plot to be more stable when comparing the values for open circuit potential, but reduces the pitting potential of the passivating oxides. Confocal microscopy showed that samples with applied tensile stress produced a much higher density of localized corrosion, including pitting and intergranular corrosion than samples without applied tensile stress. The degree of corrosion damage was slightly higher for samples loaded in the transverse direction compared to samples loaded in the longitudinal direction."],"dc:description.uri":["http://archive.org/details/theeffectofpplie1094547281"],"dc:identifier.uri":["https://hdl.handle.net/10945/47281"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["fcd0a3e4-3370-4559-99ee-72c50043ad3c"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Aluminum alloy","AA5083","IGSCC","intergranular stress corrosion cracking","localized corrosion","sensitized aluminum"],"dc:title":["The effect of applied tensile stress on localized corrosion in sensitized AA5083"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Mechanical Engineering"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:35:56Z"}