{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/4760"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/4760","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Transport Imaging developing an optical technique to characterize bulk semiconductor materials for next generation radiation detectors","abstract":"Characterization of the mobility-lifetime product is critical to the development of new materials for semiconductor radiation detectors. An optical technique has been developed that allows for the direct determination of the minority carrier diffusion length, drift length, and mobility-lifetime product from a single image of the recombination luminescence in semiconductor materials. Excess carriers are generated using the electron beam in a scanning electron microscope. The charge is then drifted by applying an electric field, and the subsequent recombination luminescence is imaged by an optical microscope on a high-sensitivity CCD camera. The challenge in applying this technique to new materials for nuclear radiation detectors is the requirement for thick samples and the resultant need to characterize transport in three dimensions. In this work, initial research was performed on the simulations and analysis of experimental data required to characterize thick layers of high purity GaAs for nuclear radiation detectors. The first models were applied to extract values for surface recombination velocity, which plays a key role in determining the excess carrier distribution in bulk materials. Cathodoluminescence of one promising high Z material, BiFeO3, is performed.","abstract_html":"Characterization of the mobility-lifetime product is critical to the development of new materials for semiconductor radiation detectors. An optical technique has been developed that allows for the direct determination of the minority carrier diffusion length, drift length, and mobility-lifetime product from a single image of the recombination luminescence in semiconductor materials. Excess carriers are generated using the electron beam in a scanning electron microscope. The charge is then drifted by applying an electric field, and the subsequent recombination luminescence is imaged by an optical microscope on a high-sensitivity CCD camera. The challenge in applying this technique to new materials for nuclear radiation detectors is the requirement for thick samples and the resultant need to characterize transport in three dimensions. In this work, initial research was performed on the simulations and analysis of experimental data required to characterize thick layers of high purity GaAs for nuclear radiation detectors. The first models were applied to extract values for surface recombination velocity, which plays a key role in determining the excess carrier distribution in bulk materials. Cathodoluminescence of one promising high Z material, BiFeO3, is performed.","abstract_has_math":false,"creators":["Catalano, Sarah L."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":["Haegel, Nancy M."],"committee_chairs":[],"committee_members":["Smith, Craig F."],"year":2009,"date_issued":"2009-06","date_published":"2009-06","updated_at":"2026-11-26T00:21:19Z","subjects":["Cathodoluminescence","Diffusion","Drift"],"languages":[],"rights":["Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["424606927"],"render_values":[{"text":"424606927","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/4760","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/4760","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F4760","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F4760","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Haegel, Nancy M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Smith, Craig F."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Catalano, Sarah L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:42:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:42:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Cathodoluminescence","Diffusion","Drift"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["424606927"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/4760"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Characterization of the mobility-lifetime product is critical to the development of new materials for semiconductor radiation detectors. An optical technique has been developed that allows for the direct determination of the minority carrier diffusion length, drift length, and mobility-lifetime product from a single image of the recombination luminescence in semiconductor materials. Excess carriers are generated using the electron beam in a scanning electron microscope. The charge is then drifted by applying an electric field, and the subsequent recombination luminescence is imaged by an optical microscope on a high-sensitivity CCD camera. The challenge in applying this technique to new materials for nuclear radiation detectors is the requirement for thick samples and the resultant need to characterize transport in three dimensions. In this work, initial research was performed on the simulations and analysis of experimental data required to characterize thick layers of high purity GaAs for nuclear radiation detectors. The first models were applied to extract values for surface recombination velocity, which plays a key role in determining the excess carrier distribution in bulk materials. Cathodoluminescence of one promising high Z material, BiFeO3, is performed."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/transportimaging109454760"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 63 p. : col. ill. ;"]},{"key":"dc:title","label":"Title","values":["Transport Imaging developing an optical technique to characterize bulk semiconductor materials for next generation radiation detectors"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["US Navy (USN) author."]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Haegel, Nancy M."],"dc:contributor.committeemember":["Smith, Craig F."],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Catalano, Sarah L."],"dc:date.accessioned":["2012-03-14T17:42:55Z"],"dc:date.available":["2012-03-14T17:42:55Z"],"dc:date.issued":["2009-06"],"dc:description.abstract":["Characterization of the mobility-lifetime product is critical to the development of new materials for semiconductor radiation detectors. An optical technique has been developed that allows for the direct determination of the minority carrier diffusion length, drift length, and mobility-lifetime product from a single image of the recombination luminescence in semiconductor materials. Excess carriers are generated using the electron beam in a scanning electron microscope. The charge is then drifted by applying an electric field, and the subsequent recombination luminescence is imaged by an optical microscope on a high-sensitivity CCD camera. The challenge in applying this technique to new materials for nuclear radiation detectors is the requirement for thick samples and the resultant need to characterize transport in three dimensions. In this work, initial research was performed on the simulations and analysis of experimental data required to characterize thick layers of high purity GaAs for nuclear radiation detectors. The first models were applied to extract values for surface recombination velocity, which plays a key role in determining the excess carrier distribution in bulk materials. Cathodoluminescence of one promising high Z material, BiFeO3, is performed."],"dc:description.uri":["http://archive.org/details/transportimaging109454760"],"dc:format.extent":["xiv, 63 p. : col. ill. ;"],"dc:identifier.oclc":["424606927"],"dc:identifier.uri":["https://hdl.handle.net/10945/4760"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Cathodoluminescence","Diffusion","Drift"],"dc:title":["Transport Imaging developing an optical technique to characterize bulk semiconductor materials for next generation radiation detectors"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["US Navy (USN) author."],"local:etd.verified":["no"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:21:19Z"}