{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/5269"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/5269","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"A method for testing the dynamic accuracy of Microelectro-Mechanical Systems (MEMS) Magnetic, Angular Rate, and Gravity (MARG) sensors for Inertial Navigation Systems (INS) and human motion tracking applications","abstract":"In this thesis a method for testing the dynamic accuracy of micro-electro-mechanical systems (MEMS) magnetic, angular rate, and gravity (MARG) sensors was developed. Many tests exist to check the static accuracy of MARG and inertial sensors or their individual components, but very few tests exist that adequately examine the dynamic accuracy of the final sensor package with sufficient precision and test repeatability. Based on a previous work that developed an inertial sensor test bench, a new test apparatus designed to model the motions of a human arm or leg was built using a rigid pendulum with MEMS MARG sensors attached on the end. Building materials were chosen to give minimal magnetic interference, and an optical encoder was used to accurately track the angle of the pendulum. A LabVIEW data acquisition system was built for data collection and a graphical user interface was written in MATLAB for easy data processing. The MicroStrain 3DM-GX1 and 3DM-GX3 sensors were tested on the new apparatus in a variety of dynamic motion tests, including free swinging in vertical and horizontal orientations, as well as \"swing to impact\" and semi-static tests, and their performances were compared for different target applications.","abstract_html":"In this thesis a method for testing the dynamic accuracy of micro-electro-mechanical systems (MEMS) magnetic, angular rate, and gravity (MARG) sensors was developed. Many tests exist to check the static accuracy of MARG and inertial sensors or their individual components, but very few tests exist that adequately examine the dynamic accuracy of the final sensor package with sufficient precision and test repeatability. Based on a previous work that developed an inertial sensor test bench, a new test apparatus designed to model the motions of a human arm or leg was built using a rigid pendulum with MEMS MARG sensors attached on the end. Building materials were chosen to give minimal magnetic interference, and an optical encoder was used to accurately track the angle of the pendulum. A LabVIEW data acquisition system was built for data collection and a graphical user interface was written in MATLAB for easy data processing. The MicroStrain 3DM-GX1 and 3DM-GX3 sensors were tested on the new apparatus in a variety of dynamic motion tests, including free swinging in vertical and horizontal orientations, as well as &quot;swing to impact&quot; and semi-static tests, and their performances were compared for different target applications.","abstract_has_math":false,"creators":["Cookson, Jeremy L."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Yun, Xiaoping"],"committee_chairs":[],"committee_members":["Romano, Marcello"],"year":2010,"date_issued":"2010-06","date_published":"2010-06","updated_at":"2026-11-26T00:11:31Z","subjects":["Microelectromechanical systems","Electrical engineering","Gyroscopes"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["648174481"],"render_values":[{"text":"648174481","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/5269","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/5269","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F5269","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F5269","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yun, Xiaoping"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Romano, Marcello"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Cookson, Jeremy L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:44:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:44:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Microelectromechanical systems","Electrical engineering","Gyroscopes"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["648174481"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/5269"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis a method for testing the dynamic accuracy of micro-electro-mechanical systems (MEMS) magnetic, angular rate, and gravity (MARG) sensors was developed. Many tests exist to check the static accuracy of MARG and inertial sensors or their individual components, but very few tests exist that adequately examine the dynamic accuracy of the final sensor package with sufficient precision and test repeatability. Based on a previous work that developed an inertial sensor test bench, a new test apparatus designed to model the motions of a human arm or leg was built using a rigid pendulum with MEMS MARG sensors attached on the end. Building materials were chosen to give minimal magnetic interference, and an optical encoder was used to accurately track the angle of the pendulum. A LabVIEW data acquisition system was built for data collection and a graphical user interface was written in MATLAB for easy data processing. The MicroStrain 3DM-GX1 and 3DM-GX3 sensors were tested on the new apparatus in a variety of dynamic motion tests, including free swinging in vertical and horizontal orientations, as well as \"swing to impact\" and semi-static tests, and their performances were compared for different target applications."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/amethodfortestin109455269"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xxiv, 191 p. : ill. (some col.) ;"]},{"key":"dc:title","label":"Title","values":["A method for testing the dynamic accuracy of Microelectro-Mechanical Systems (MEMS) Magnetic, Angular Rate, and Gravity (MARG) sensors for Inertial Navigation Systems (INS) and human motion tracking applications"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["US Air Force (USAF) author (civilian)"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yun, Xiaoping"],"dc:contributor.committeemember":["Romano, Marcello"],"dc:contributor.department":["Electrical Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Cookson, Jeremy L."],"dc:date.accessioned":["2012-03-14T17:44:49Z"],"dc:date.available":["2012-03-14T17:44:49Z"],"dc:date.issued":["2010-06"],"dc:description.abstract":["In this thesis a method for testing the dynamic accuracy of micro-electro-mechanical systems (MEMS) magnetic, angular rate, and gravity (MARG) sensors was developed. Many tests exist to check the static accuracy of MARG and inertial sensors or their individual components, but very few tests exist that adequately examine the dynamic accuracy of the final sensor package with sufficient precision and test repeatability. Based on a previous work that developed an inertial sensor test bench, a new test apparatus designed to model the motions of a human arm or leg was built using a rigid pendulum with MEMS MARG sensors attached on the end. Building materials were chosen to give minimal magnetic interference, and an optical encoder was used to accurately track the angle of the pendulum. A LabVIEW data acquisition system was built for data collection and a graphical user interface was written in MATLAB for easy data processing. The MicroStrain 3DM-GX1 and 3DM-GX3 sensors were tested on the new apparatus in a variety of dynamic motion tests, including free swinging in vertical and horizontal orientations, as well as \"swing to impact\" and semi-static tests, and their performances were compared for different target applications."],"dc:description.uri":["http://archive.org/details/amethodfortestin109455269"],"dc:format.extent":["xxiv, 191 p. : ill. (some col.) ;"],"dc:identifier.oclc":["648174481"],"dc:identifier.uri":["https://hdl.handle.net/10945/5269"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Microelectromechanical systems","Electrical engineering","Gyroscopes"],"dc:title":["A method for testing the dynamic accuracy of Microelectro-Mechanical Systems (MEMS) Magnetic, Angular Rate, and Gravity (MARG) sensors for Inertial Navigation Systems (INS) and human motion tracking applications"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["US Air Force (USAF) author (civilian)"],"local:etd.verified":["no"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-26T00:11:31Z"}