{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/5630"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/5630","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Coherent noise rejection in a three-phase power inverter","abstract":"In this thesis, we discuss the design of a controller to reject the effects of high order harmonics in a three-phase power inverter. Specifically, coherent noise in the fifth harmonic is considered, as it seems to be dominant in most applications. The controller used in this power inverter operates in a reference frame synchronous with the 60 Hz line voltage. This transformation effectively changes the desired 60 Hz sine wave output into a DC value that has the same amplitude as the sine wave. The power inverter uses an optimal form of pulse-width modulation (PWM), called space vector modulation, which causes the harmonic noise. In order to reject the distortions introduced by the space-vector modulation process, a Linear Quadratic Gaussian (LQG) controller is designed with the sinusoidal disturbances modeled as uncontrollable modes of the system, which are observable from the input and output signals. The extra states in the state space model associated with the disturbance are estimated by the Kalman Filter and subtracted from the control input to compensate for the disturbance","abstract_html":"In this thesis, we discuss the design of a controller to reject the effects of high order harmonics in a three-phase power inverter. Specifically, coherent noise in the fifth harmonic is considered, as it seems to be dominant in most applications. The controller used in this power inverter operates in a reference frame synchronous with the 60 Hz line voltage. This transformation effectively changes the desired 60 Hz sine wave output into a DC value that has the same amplitude as the sine wave. The power inverter uses an optimal form of pulse-width modulation (PWM), called space vector modulation, which causes the harmonic noise. In order to reject the distortions introduced by the space-vector modulation process, a Linear Quadratic Gaussian (LQG) controller is designed with the sinusoidal disturbances modeled as uncontrollable modes of the system, which are observable from the input and output signals. The extra states in the state space model associated with the disturbance are estimated by the Kalman Filter and subtracted from the control input to compensate for the disturbance","abstract_has_math":false,"creators":["Wheaton, Daniel G."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"M.S.","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":["Cristi, Roberto","Julian, Alexander L."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-06","date_published":"2011-06","updated_at":"2026-11-19T06:38:17Z","subjects":["Pulse-duration modulation"],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["743348604"],"render_values":[{"text":"743348604","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/5630","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/5630","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F5630","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F5630","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cristi, Roberto","Julian, Alexander L."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Naval Postgraduate School (U.S.)"]},{"key":"dc:creator","label":"Author","values":["Wheaton, Daniel G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:46:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:46:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Pulse-duration modulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["743348604"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/5630"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, we discuss the design of a controller to reject the effects of high order harmonics in a three-phase power inverter. Specifically, coherent noise in the fifth harmonic is considered, as it seems to be dominant in most applications. The controller used in this power inverter operates in a reference frame synchronous with the 60 Hz line voltage. This transformation effectively changes the desired 60 Hz sine wave output into a DC value that has the same amplitude as the sine wave. The power inverter uses an optimal form of pulse-width modulation (PWM), called space vector modulation, which causes the harmonic noise. In order to reject the distortions introduced by the space-vector modulation process, a Linear Quadratic Gaussian (LQG) controller is designed with the sinusoidal disturbances modeled as uncontrollable modes of the system, which are observable from the input and output signals. The extra states in the state space model associated with the disturbance are estimated by the Kalman Filter and subtracted from the control input to compensate for the disturbance"]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/coherentnoiserej109455630"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xvi, 37 p. : some col. ill. ;"]},{"key":"dc:title","label":"Title","values":["Coherent noise rejection in a three-phase power inverter"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:etd.verified","label":"Local Etd Verified","values":["no"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cristi, Roberto","Julian, Alexander L."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:contributor.other":["Naval Postgraduate School (U.S.)"],"dc:creator":["Wheaton, Daniel G."],"dc:date.accessioned":["2012-03-14T17:46:11Z"],"dc:date.available":["2012-03-14T17:46:11Z"],"dc:date.issued":["2011-06"],"dc:description.abstract":["In this thesis, we discuss the design of a controller to reject the effects of high order harmonics in a three-phase power inverter. Specifically, coherent noise in the fifth harmonic is considered, as it seems to be dominant in most applications. The controller used in this power inverter operates in a reference frame synchronous with the 60 Hz line voltage. This transformation effectively changes the desired 60 Hz sine wave output into a DC value that has the same amplitude as the sine wave. The power inverter uses an optimal form of pulse-width modulation (PWM), called space vector modulation, which causes the harmonic noise. In order to reject the distortions introduced by the space-vector modulation process, a Linear Quadratic Gaussian (LQG) controller is designed with the sinusoidal disturbances modeled as uncontrollable modes of the system, which are observable from the input and output signals. The extra states in the state space model associated with the disturbance are estimated by the Kalman Filter and subtracted from the control input to compensate for the disturbance"],"dc:description.uri":["http://archive.org/details/coherentnoiserej109455630"],"dc:format.extent":["xvi, 37 p. : some col. ill. ;"],"dc:identifier.oclc":["743348604"],"dc:identifier.uri":["https://hdl.handle.net/10945/5630"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.lcsh":["Pulse-duration modulation"],"dc:title":["Coherent noise rejection in a three-phase power inverter"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:etd.verified":["no"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:38:17Z"}