{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/5648"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/5648","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Transient behavior of light-emitting electrochemical cells","abstract":"Recent prototypes of the individual identification friend or foe (IIFF) patch use a light-emitting electrochemical cell (LEC) as the emitter. This research characterizes the transient behavior of LECs by measuring transient capacitance. The transient capacitance data are important to improve understanding of the underlying physics describing the operation of the LEC. The research goal was to make the first transient measurements of an LEC's capacitance as a function of temperature and bias, while simultaneously measuring the transient light output and current, to monitor in-situ junction formation inside an LEC. Capacitance changes varying from 5-30 nF are measured, depending on applied voltage and device temperature. Strong temperature dependence of the rate of change of capacitance suggests Arrhenius-type behavior associated with ion motion with an activation energy of 1.27 eV. The initial rate of change of capacitance is faster than the rate of change of light and current, suggesting that modification of the field near the contacts plays a key role in controlling free carrier injection. Initially capacitance increases monotonically upon application of bias, however, at longer times decreasing and even oscillating capacitance has been observed. This behavior provides new information on the dynamics of ion motion and carrier injection in LECs.","abstract_html":"Recent prototypes of the individual identification friend or foe (IIFF) patch use a light-emitting electrochemical cell (LEC) as the emitter. This research characterizes the transient behavior of LECs by measuring transient capacitance. The transient capacitance data are important to improve understanding of the underlying physics describing the operation of the LEC. The research goal was to make the first transient measurements of an LEC&#x27;s capacitance as a function of temperature and bias, while simultaneously measuring the transient light output and current, to monitor in-situ junction formation inside an LEC. Capacitance changes varying from 5-30 nF are measured, depending on applied voltage and device temperature. Strong temperature dependence of the rate of change of capacitance suggests Arrhenius-type behavior associated with ion motion with an activation energy of 1.27 eV. The initial rate of change of capacitance is faster than the rate of change of light and current, suggesting that modification of the field near the contacts plays a key role in controlling free carrier injection. Initially capacitance increases monotonically upon application of bias, however, at longer times decreasing and even oscillating capacitance has been observed. This behavior provides new information on the dynamics of ion motion and carrier injection in LECs.","abstract_has_math":false,"creators":["Davis, Yevtte A."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":["Haegel, Nancy M.","Crooker, Peter P."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-06","date_published":"2011-06","updated_at":"2026-11-19T06:38:17Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["743306994"],"render_values":[{"text":"743306994","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/5648","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/5648","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F5648","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Haegel, Nancy M.","Crooker, Peter P."]},{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Davis, Yevtte A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:46:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:46:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2011-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.ispartofseries","label":"Dc Relation Ispartofseries","values":["NPS Outstanding Theses and Dissertations"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:relation.seriesentity","label":"Dc Relation Seriesentity","values":["c5e66392-520c-4aaf-9b4f-370ce82b601f"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["LEC","Transient","Capacitance","Junction","Arrhenius-type Behavior","Rate of Change","Ion Motion","Carrier Injection"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["743306994"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/5648"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent prototypes of the individual identification friend or foe (IIFF) patch use a light-emitting electrochemical cell (LEC) as the emitter. This research characterizes the transient behavior of LECs by measuring transient capacitance. The transient capacitance data are important to improve understanding of the underlying physics describing the operation of the LEC. The research goal was to make the first transient measurements of an LEC's capacitance as a function of temperature and bias, while simultaneously measuring the transient light output and current, to monitor in-situ junction formation inside an LEC. Capacitance changes varying from 5-30 nF are measured, depending on applied voltage and device temperature. Strong temperature dependence of the rate of change of capacitance suggests Arrhenius-type behavior associated with ion motion with an activation energy of 1.27 eV. The initial rate of change of capacitance is faster than the rate of change of light and current, suggesting that modification of the field near the contacts plays a key role in controlling free carrier injection. Initially capacitance increases monotonically upon application of bias, however, at longer times decreasing and even oscillating capacitance has been observed. This behavior provides new information on the dynamics of ion motion and carrier injection in LECs."]},{"key":"dc:description.award","label":"Dc Description Award","values":["Outstanding Thesis"]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Technology Transition Initiative of the Office of the Director of Defense Research and Engineering (DDRE), National Science Foundation under grant DMR 0804527"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["81 p."]},{"key":"dc:title","label":"Title","values":["Transient behavior of light-emitting electrochemical cells"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Haegel, Nancy M.","Crooker, Peter P."],"dc:contributor.department":["Physics (PH)"],"dc:creator":["Davis, Yevtte A."],"dc:date.accessioned":["2012-03-14T17:46:15Z"],"dc:date.available":["2012-03-14T17:46:15Z"],"dc:date.issued":["2011-06"],"dc:description.abstract":["Recent prototypes of the individual identification friend or foe (IIFF) patch use a light-emitting electrochemical cell (LEC) as the emitter. This research characterizes the transient behavior of LECs by measuring transient capacitance. The transient capacitance data are important to improve understanding of the underlying physics describing the operation of the LEC. The research goal was to make the first transient measurements of an LEC's capacitance as a function of temperature and bias, while simultaneously measuring the transient light output and current, to monitor in-situ junction formation inside an LEC. Capacitance changes varying from 5-30 nF are measured, depending on applied voltage and device temperature. Strong temperature dependence of the rate of change of capacitance suggests Arrhenius-type behavior associated with ion motion with an activation energy of 1.27 eV. The initial rate of change of capacitance is faster than the rate of change of light and current, suggesting that modification of the field near the contacts plays a key role in controlling free carrier injection. Initially capacitance increases monotonically upon application of bias, however, at longer times decreasing and even oscillating capacitance has been observed. This behavior provides new information on the dynamics of ion motion and carrier injection in LECs."],"dc:description.award":["Outstanding Thesis"],"dc:description.sponsorship":["Technology Transition Initiative of the Office of the Director of Defense Research and Engineering (DDRE), National Science Foundation under grant DMR 0804527"],"dc:format.extent":["81 p."],"dc:identifier.oclc":["743306994"],"dc:identifier.uri":["https://hdl.handle.net/10945/5648"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.ispartofseries":["NPS Outstanding Theses and Dissertations"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:relation.seriesentity":["c5e66392-520c-4aaf-9b4f-370ce82b601f"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Distribution Statement A. Approved for public release: Distribution is unlimited."],"dc:subject.keyword":["LEC","Transient","Capacitance","Junction","Arrhenius-type Behavior","Rate of Change","Ion Motion","Carrier Injection"],"dc:title":["Transient behavior of light-emitting electrochemical cells"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:38:17Z"}