{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/56870"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/56870","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Actinide isotope ratios measured by Resonance Ionization Mass Spectrometry: optimization of ionization schemes and demonstration using nuclear fallout","abstract":"Resonance Ionization Mass Spectrometry is a technology for analysis of isotopic composition of samples that was developed as early as the 1980s. Since its development, technological advancements have enabled instruments such as the Laser Ionization of Neutrals instrument at Lawrence Livermore National Laboratory to deliver high yield isotope ratios with an accuracy within 1% at high measurement efficiency while remaining relatively free of isobaric interferences. The instrument has recently been successfully used to quantify uranium isotope ratios in nuclear fallout debris. The work in this thesis explored three pathways necessary for the development of a field deployable instrument. The first pathway addressed was a feasibility study that showed current continuous wave laser technology incompatible with the ionization approach taken in the current Laser Ionization of Neutrals instrument. Next, new one- and two-color uranium resonance ionization schemes were tested that showed an increase in uranium signal by 62% by accessing a low-lying excited state. The final experimental investigation studied the effects of carbon coating and implantation on nuclear fallout samples, showing a factor of two increase in the signal-to-noise ratio achieved during measurement of uranium isotope ratios.","abstract_html":"Resonance Ionization Mass Spectrometry is a technology for analysis of isotopic composition of samples that was developed as early as the 1980s. Since its development, technological advancements have enabled instruments such as the Laser Ionization of Neutrals instrument at Lawrence Livermore National Laboratory to deliver high yield isotope ratios with an accuracy within 1% at high measurement efficiency while remaining relatively free of isobaric interferences. The instrument has recently been successfully used to quantify uranium isotope ratios in nuclear fallout debris. The work in this thesis explored three pathways necessary for the development of a field deployable instrument. The first pathway addressed was a feasibility study that showed current continuous wave laser technology incompatible with the ionization approach taken in the current Laser Ionization of Neutrals instrument. Next, new one- and two-color uranium resonance ionization schemes were tested that showed an increase in uranium signal by 62% by accessing a low-lying excited state. The final experimental investigation studied the effects of carbon coating and implantation on nuclear fallout samples, showing a factor of two increase in the signal-to-noise ratio achieved during measurement of uranium isotope ratios.","abstract_has_math":false,"creators":["Brewster, Drake E."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Physics","degree_level":"Masters","degree_discipline":"Physics","degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":["Smith, Craig F."],"committee_chairs":[],"committee_members":["Isselhardt, Brett H."],"year":2017,"date_issued":"2017-12","date_published":"2017-12","updated_at":"2026-11-19T06:38:17Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/56870","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/56870","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Anps%3Aoai%3Acalhoun.nps.edu%3A10945%2F56870","prefix":"oai_dc"},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F56870","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Smith, Craig F."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Isselhardt, Brett H."]},{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Brewster, Drake E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["Dec-17"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-02-07T20:36:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-02-07T20:36:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2017-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Resonance Ionization Mass Spectroscopy","RIMS"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/56870"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Resonance Ionization Mass Spectrometry is a technology for analysis of isotopic composition of samples that was developed as early as the 1980s. Since its development, technological advancements have enabled instruments such as the Laser Ionization of Neutrals instrument at Lawrence Livermore National Laboratory to deliver high yield isotope ratios with an accuracy within 1% at high measurement efficiency while remaining relatively free of isobaric interferences. The instrument has recently been successfully used to quantify uranium isotope ratios in nuclear fallout debris. The work in this thesis explored three pathways necessary for the development of a field deployable instrument. The first pathway addressed was a feasibility study that showed current continuous wave laser technology incompatible with the ionization approach taken in the current Laser Ionization of Neutrals instrument. Next, new one- and two-color uranium resonance ionization schemes were tested that showed an increase in uranium signal by 62% by accessing a low-lying excited state. The final experimental investigation studied the effects of carbon coating and implantation on nuclear fallout samples, showing a factor of two increase in the signal-to-noise ratio achieved during measurement of uranium isotope ratios."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/actinideisotoper1094556870"]},{"key":"dc:title","label":"Title","values":["Actinide isotope ratios measured by Resonance Ionization Mass Spectrometry: optimization of ionization schemes and demonstration using nuclear fallout"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Captain, United States Army"]}]}],"canonical_facts":{"dc:contributor.advisor":["Smith, Craig F."],"dc:contributor.committeemember":["Isselhardt, Brett H."],"dc:contributor.department":["Physics (PH)"],"dc:creator":["Brewster, Drake E."],"dc:date":["Dec-17"],"dc:date.accessioned":["2018-02-07T20:36:10Z"],"dc:date.available":["2018-02-07T20:36:10Z"],"dc:date.issued":["2017-12"],"dc:description.abstract":["Resonance Ionization Mass Spectrometry is a technology for analysis of isotopic composition of samples that was developed as early as the 1980s. Since its development, technological advancements have enabled instruments such as the Laser Ionization of Neutrals instrument at Lawrence Livermore National Laboratory to deliver high yield isotope ratios with an accuracy within 1% at high measurement efficiency while remaining relatively free of isobaric interferences. The instrument has recently been successfully used to quantify uranium isotope ratios in nuclear fallout debris. The work in this thesis explored three pathways necessary for the development of a field deployable instrument. The first pathway addressed was a feasibility study that showed current continuous wave laser technology incompatible with the ionization approach taken in the current Laser Ionization of Neutrals instrument. Next, new one- and two-color uranium resonance ionization schemes were tested that showed an increase in uranium signal by 62% by accessing a low-lying excited state. The final experimental investigation studied the effects of carbon coating and implantation on nuclear fallout samples, showing a factor of two increase in the signal-to-noise ratio achieved during measurement of uranium isotope ratios."],"dc:description.uri":["http://archive.org/details/actinideisotoper1094556870"],"dc:identifier.uri":["https://hdl.handle.net/10945/56870"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Resonance Ionization Mass Spectroscopy","RIMS"],"dc:title":["Actinide isotope ratios measured by Resonance Ionization Mass Spectrometry: optimization of ionization schemes and demonstration using nuclear fallout"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Captain, United States Army"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:38:17Z"}