{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/59577"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/59577","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"MODELING AND CONTROL OF A MICROGRID USING A HYBRID ENERGY STORAGE SYSTEM WITH SUPERCAPACITORS","abstract":"Lead-acid batteries have traditionally been used for energy storage in microgrid applications. Implementing an Energy Management System (EMS)-controlled supercapacitor (SC) and lead-acid battery hybrid energy storage system (HESS) has been shown to reduce operational costs by extending battery lifetimes. The SCs can be controlled to provide the high-frequency, power-dense component of the load power, which reduces the daily cyclical stress and state-of-charge (SOC) depletion of the lead-acid batteries; however, the HESS must be appropriately sized based on cost constraints, available power sources, and load demand. The enabling theory and design of a SIMULINK model of a DC microgrid are discussed in this thesis. The results obtained from this model illustrate the energy exchange between microgrid components, demonstrate some of the potential benefits of implementing a HESS, and provide useful data for battery and SC sizing. The DC microgrid model is scalable and can use any user-defined combination of source and load profiles. In islanded mode, the lead-acid battery and SC banks need to be unrealistically large to provide adequate power to the load. In grid-connected mode, the HESS sizing requirements are significantly reduced, and the overall energy savings of the system are improved.","abstract_html":"Lead-acid batteries have traditionally been used for energy storage in microgrid applications. Implementing an Energy Management System (EMS)-controlled supercapacitor (SC) and lead-acid battery hybrid energy storage system (HESS) has been shown to reduce operational costs by extending battery lifetimes. The SCs can be controlled to provide the high-frequency, power-dense component of the load power, which reduces the daily cyclical stress and state-of-charge (SOC) depletion of the lead-acid batteries; however, the HESS must be appropriately sized based on cost constraints, available power sources, and load demand. The enabling theory and design of a SIMULINK model of a DC microgrid are discussed in this thesis. The results obtained from this model illustrate the energy exchange between microgrid components, demonstrate some of the potential benefits of implementing a HESS, and provide useful data for battery and SC sizing. The DC microgrid model is scalable and can use any user-defined combination of source and load profiles. In islanded mode, the lead-acid battery and SC banks need to be unrealistically large to provide adequate power to the load. In grid-connected mode, the HESS sizing requirements are significantly reduced, and the overall energy savings of the system are improved.","abstract_has_math":false,"creators":["Ross, Michael J. Jr."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Electrical Engineering","degree_level":"Masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering (ECE)","school":null,"contributors":[],"advisors":["Cristi, Roberto","Oriti, Giovanna"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-06","date_published":"2018-06","updated_at":"2026-11-19T06:38:38Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["29669"],"render_values":[{"text":"29669","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/59577","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/59577","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F59577","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cristi, Roberto","Oriti, Giovanna"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering (ECE)"]},{"key":"dc:creator","label":"Author","values":["Ross, Michael J. Jr."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-08-24T22:34:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-08-24T22:34:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2018-06"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.advisorentity","label":"Dc Relation Advisorentity","values":["f4822f3e-2aea-40ad-9b4a-288607743ad7"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Electrical Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["29669"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Energy Management System (EMS)","hybrid energy storage system (HESS)","lead-acid battery","supercapacitor (SC)","microgrid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/59577"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lead-acid batteries have traditionally been used for energy storage in microgrid applications. Implementing an Energy Management System (EMS)-controlled supercapacitor (SC) and lead-acid battery hybrid energy storage system (HESS) has been shown to reduce operational costs by extending battery lifetimes. The SCs can be controlled to provide the high-frequency, power-dense component of the load power, which reduces the daily cyclical stress and state-of-charge (SOC) depletion of the lead-acid batteries; however, the HESS must be appropriately sized based on cost constraints, available power sources, and load demand. The enabling theory and design of a SIMULINK model of a DC microgrid are discussed in this thesis. The results obtained from this model illustrate the energy exchange between microgrid components, demonstrate some of the potential benefits of implementing a HESS, and provide useful data for battery and SC sizing. The DC microgrid model is scalable and can use any user-defined combination of source and load profiles. In islanded mode, the lead-acid battery and SC banks need to be unrealistically large to provide adequate power to the load. In grid-connected mode, the HESS sizing requirements are significantly reduced, and the overall energy savings of the system are improved."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/modelingandcontr1094559577"]},{"key":"dc:title","label":"Title","values":["MODELING AND CONTROL OF A MICROGRID USING A HYBRID ENERGY STORAGE SYSTEM WITH SUPERCAPACITORS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Ensign, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cristi, Roberto","Oriti, Giovanna"],"dc:contributor.department":["Electrical and Computer Engineering (ECE)"],"dc:creator":["Ross, Michael J. Jr."],"dc:date.accessioned":["2018-08-24T22:34:16Z"],"dc:date.available":["2018-08-24T22:34:16Z"],"dc:date.issued":["2018-06"],"dc:description.abstract":["Lead-acid batteries have traditionally been used for energy storage in microgrid applications. Implementing an Energy Management System (EMS)-controlled supercapacitor (SC) and lead-acid battery hybrid energy storage system (HESS) has been shown to reduce operational costs by extending battery lifetimes. The SCs can be controlled to provide the high-frequency, power-dense component of the load power, which reduces the daily cyclical stress and state-of-charge (SOC) depletion of the lead-acid batteries; however, the HESS must be appropriately sized based on cost constraints, available power sources, and load demand. The enabling theory and design of a SIMULINK model of a DC microgrid are discussed in this thesis. The results obtained from this model illustrate the energy exchange between microgrid components, demonstrate some of the potential benefits of implementing a HESS, and provide useful data for battery and SC sizing. The DC microgrid model is scalable and can use any user-defined combination of source and load profiles. In islanded mode, the lead-acid battery and SC banks need to be unrealistically large to provide adequate power to the load. In grid-connected mode, the HESS sizing requirements are significantly reduced, and the overall energy savings of the system are improved."],"dc:description.uri":["http://archive.org/details/modelingandcontr1094559577"],"dc:identifier.uri":["https://hdl.handle.net/10945/59577"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.advisorentity":["f4822f3e-2aea-40ad-9b4a-288607743ad7"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Energy Management System (EMS)","hybrid energy storage system (HESS)","lead-acid battery","supercapacitor (SC)","microgrid"],"dc:title":["MODELING AND CONTROL OF A MICROGRID USING A HYBRID ENERGY STORAGE SYSTEM WITH SUPERCAPACITORS"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Ensign, United States Navy"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Electrical Engineering"],"thesis:institution_name":["Naval Postgraduate School"],"thesis:thesis_identifier":["29669"]},"updated_at":"2026-11-19T06:38:38Z"}