{"id":{"repo_id":"nps","oai_identifier":"oai:calhoun.nps.edu:10945/5965"},"canonical_url":"https://search.ndltd.org/etd/nps/oai:calhoun.nps.edu:10945/5965","repository":{"repo_id":"nps","name":"Naval Postgraduate School","base_url":"https://calhoun.nps.edu/server/oai/request"},"display":{"title":"Absolute calibration techniques for UV spectroscopy based upon platinum emission line spectra","abstract":"Imaging spectrometry requires precise knowledge of wavelength in order to perform various spectral analyses. This thesis project was tasked with performing wavelength calibration as part of the ongoing development of the Naval Postgraduate SchoolÎ±s Lineate Imaging Near Ultraviolet Spectrometer (LINUS). This calibration was necessary for the ability of LINUS to detect, to classify, and to quantify several different chemical species by observation over the near-ultraviolet wavelength band of 200 to 400 nm. Experiments were conducted to detect diffracted emission lines from a platinum hollow cathode lamp by using the LINUS optical train and five different UV filters. A Matlab program was developed to compare the catalogued wavelengths of this known ultraviolet source with the emission line positions observed on the LINUS detector. Affine transformation and cross-correlation of the data produced wavelength calibration curves for the LINUS detector in each of the five associated UV wavelength regions.","abstract_html":"Imaging spectrometry requires precise knowledge of wavelength in order to perform various spectral analyses. This thesis project was tasked with performing wavelength calibration as part of the ongoing development of the Naval Postgraduate SchoolÎ±s Lineate Imaging Near Ultraviolet Spectrometer (LINUS). This calibration was necessary for the ability of LINUS to detect, to classify, and to quantify several different chemical species by observation over the near-ultraviolet wavelength band of 200 to 400 nm. Experiments were conducted to detect diffracted emission lines from a platinum hollow cathode lamp by using the LINUS optical train and five different UV filters. A Matlab program was developed to compare the catalogued wavelengths of this known ultraviolet source with the emission line positions observed on the LINUS detector. Affine transformation and cross-correlation of the data produced wavelength calibration curves for the LINUS detector in each of the five associated UV wavelength regions.","abstract_has_math":false,"creators":["Kuriger, Daniel W."],"institution":"Monterey, CA; Naval Postgraduate School","degree_name":"Master of Science in Applied Physics","degree_level":"Masters","degree_discipline":"Applied Physics","degree_department":"Physics (PH)","school":null,"contributors":[],"advisors":["Davis, D. Scott","Harkins, Richard"],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001-12","date_published":"2001-12","updated_at":"2026-11-19T06:38:38Z","subjects":[],"languages":[],"rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["640961384"],"render_values":[{"text":"640961384","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10945/5965","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10945/5965","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://calhoun.nps.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Acalhoun.nps.edu%3A10945%2F5965","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Davis, D. Scott","Harkins, Richard"]},{"key":"dc:contributor.department","label":"Department","values":["Physics (PH)"]},{"key":"dc:creator","label":"Author","values":["Kuriger, Daniel W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-03-14T17:47:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-03-14T17:47:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2001-12"]},{"key":"dc:publisher","label":"Institution","values":["Monterey, CA; Naval Postgraduate School"]},{"key":"dc:relation.orgunit","label":"Dc Relation Orgunit","values":["0966cedc-9b4d-44f6-932d-51786e48444d"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Applied Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Applied Physics"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Naval Postgraduate School"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Calibration","Hyperspectral","Sensors","Spectral Imaging","Spectrometer","Remote Sensing","Ultraviolet"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["640961384"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10945/5965"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Imaging spectrometry requires precise knowledge of wavelength in order to perform various spectral analyses. This thesis project was tasked with performing wavelength calibration as part of the ongoing development of the Naval Postgraduate SchoolÎ±s Lineate Imaging Near Ultraviolet Spectrometer (LINUS). This calibration was necessary for the ability of LINUS to detect, to classify, and to quantify several different chemical species by observation over the near-ultraviolet wavelength band of 200 to 400 nm. Experiments were conducted to detect diffracted emission lines from a platinum hollow cathode lamp by using the LINUS optical train and five different UV filters. A Matlab program was developed to compare the catalogued wavelengths of this known ultraviolet source with the emission line positions observed on the LINUS detector. Affine transformation and cross-correlation of the data produced wavelength calibration curves for the LINUS detector in each of the five associated UV wavelength regions."]},{"key":"dc:description.uri","label":"Dc Description URI","values":["http://archive.org/details/absolutecalibrat109455965"]},{"key":"dc:title","label":"Title","values":["Absolute calibration techniques for UV spectroscopy based upon platinum emission line spectra"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:contributor.affiliation","label":"Local Contributor Affiliation","values":["Lieutenant, United States Navy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Davis, D. Scott","Harkins, Richard"],"dc:contributor.department":["Physics (PH)"],"dc:creator":["Kuriger, Daniel W."],"dc:date.accessioned":["2012-03-14T17:47:21Z"],"dc:date.available":["2012-03-14T17:47:21Z"],"dc:date.issued":["2001-12"],"dc:description.abstract":["Imaging spectrometry requires precise knowledge of wavelength in order to perform various spectral analyses. This thesis project was tasked with performing wavelength calibration as part of the ongoing development of the Naval Postgraduate SchoolÎ±s Lineate Imaging Near Ultraviolet Spectrometer (LINUS). This calibration was necessary for the ability of LINUS to detect, to classify, and to quantify several different chemical species by observation over the near-ultraviolet wavelength band of 200 to 400 nm. Experiments were conducted to detect diffracted emission lines from a platinum hollow cathode lamp by using the LINUS optical train and five different UV filters. A Matlab program was developed to compare the catalogued wavelengths of this known ultraviolet source with the emission line positions observed on the LINUS detector. Affine transformation and cross-correlation of the data produced wavelength calibration curves for the LINUS detector in each of the five associated UV wavelength regions."],"dc:description.uri":["http://archive.org/details/absolutecalibrat109455965"],"dc:identifier.oclc":["640961384"],"dc:identifier.uri":["https://hdl.handle.net/10945/5965"],"dc:publisher":["Monterey, CA; Naval Postgraduate School"],"dc:relation.orgunit":["0966cedc-9b4d-44f6-932d-51786e48444d"],"dc:rights":["This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.","Approved for public release; distribution is unlimited."],"dc:subject.keyword":["Calibration","Hyperspectral","Sensors","Spectral Imaging","Spectrometer","Remote Sensing","Ultraviolet"],"dc:title":["Absolute calibration techniques for UV spectroscopy based upon platinum emission line spectra"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"local:contributor.affiliation":["Lieutenant, United States Navy"],"thesis:degree_discipline":["Applied Physics"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Applied Physics"],"thesis:institution_name":["Naval Postgraduate School"]},"updated_at":"2026-11-19T06:38:38Z"}